• 제목/요약/키워드: Internal Layer

검색결과 940건 처리시간 0.024초

선택적 레이저 용융 공정으로 제작된 시편의 SUS316L 에너지밀도 및 비드 중첩률에 따른 기계적 특성 변화 분석 (Impact of Energy Density and Bead Overlap Ratio of a SUS316L Specimen Fabricated using Selective Laser Melting on Mechanical Characteristics)

  • 이동욱;김우성;성지현;김철;이호진
    • 한국기계가공학회지
    • /
    • 제20권8호
    • /
    • pp.42-51
    • /
    • 2021
  • Investigations of process parameters are essential when fabricating high-quality parts using additive manufacturing. This study investigates the change in the mechanical characteristics of a SUS316L specimen fabricated using selective laser melting based on the energy density and bead overlap ratio. The SUS316L powder particles were spherical and 35 ㎛ in size. Single-bead and hexahedral shape deposition experiments were performed sequentially. A single bead experiment was performed to obtain the bead overlap ratios for different laser parameters utilizing laser power and scan speed as experimental parameters. A hexahedral shape deposition experiment was also performed to observe the difference in mechanical properties, such as the internal porosity, surface roughness, and hardness, based on the energy density and bead overlap ratio of the three-dimensional printed part. Laser power, scan speed, overlap ratio, and layer thickness were chosen as parameters for the hexahedral shape deposition experiment. Accordingly, the energy density applied for three-dimensional printing, and the experimental parameters were calculated, and the energy density and bead overlap ratio for fabricating parts with good properties have been suggested.

고해상도 지상 기온 상세화 모델 개발 (Development of a High-Resolution Near-Surface Air Temperature Downscale Model)

  • 이두일;이상현;정형세;김연희
    • 대기
    • /
    • 제31권5호
    • /
    • pp.473-488
    • /
    • 2021
  • A new physical/statistical diagnostic downscale model has been developed for use to improve near-surface air temperature forecasts. The model includes a series of physical and statistical correction methods that account for un-resolved topographic and land-use effects as well as statistical bias errors in a low-resolution atmospheric model. Operational temperature forecasts of the Local Data Assimilation and Prediction System (LDAPS) were downscaled at 100 m resolution for three months, which were used to validate the model's physical and statistical correction methods and to compare its performance with the forecasts of the Korea Meteorological Administration Post-processing (KMAP) system. The validation results showed positive impacts of the un-resolved topographic and urban effects (topographic height correction, valley cold air pool effect, mountain internal boundary layer formation effect, urban land-use effect) in complex terrain areas. In addition, the statistical bias correction of the LDAPS model were efficient in reducing forecast errors of the near-surface temperatures. The new high-resolution downscale model showed better agreement against Korean 584 meteorological monitoring stations than the KMAP, supporting the importance of the new physical and statistical correction methods. The new physical/statistical diagnostic downscale model can be a useful tool in improving near-surface temperature forecasts and diagnostics over complex terrain areas.

A multi-layer approach to DN 50 electric valve fault diagnosis using shallow-deep intelligent models

  • Liu, Yong-kuo;Zhou, Wen;Ayodeji, Abiodun;Zhou, Xin-qiu;Peng, Min-jun;Chao, Nan
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.148-163
    • /
    • 2021
  • Timely fault identification is important for safe and reliable operation of the electric valve system. Many research works have utilized different data-driven approach for fault diagnosis in complex systems. However, they do not consider specific characteristics of critical control components such as electric valves. This work presents an integrated shallow-deep fault diagnostic model, developed based on signals extracted from DN50 electric valve. First, the local optimal issue of particle swarm optimization algorithm is solved by optimizing the weight search capability, the particle speed, and position update strategy. Then, to develop a shallow diagnostic model, the modified particle swarm algorithm is combined with support vector machine to form a hybrid improved particle swarm-support vector machine (IPs-SVM). To decouple the influence of the background noise, the wavelet packet transform method is used to reconstruct the vibration signal. Thereafter, the IPs-SVM is used to classify phase imbalance and damaged valve faults, and the performance was evaluated against other models developed using the conventional SVM and particle swarm optimized SVM. Secondly, three different deep belief network (DBN) models are developed, using different acoustic signal structures: raw signal, wavelet transformed signal and time-series (sequential) signal. The models are developed to estimate internal leakage sizes in the electric valve. The predictive performance of the DBN and the evaluation results of the proposed IPs-SVM are also presented in this paper.

SSD FTL 캐시 알고리즘 분석 및 제언 (Analysis and Advice on Cache Algorithms of SSD FTL)

  • 이형봉;정태윤
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제12권1호
    • /
    • pp.1-8
    • /
    • 2023
  • SSD는 이미 할당된 페이지에 대한 제자리 덮어쓰기가 불가능하므로 쓰기 연산이 있을 때마다 새로운 클린 페이지로의 대체가 필요하다. 이 문제를 지원하기 위해 SSD는 운영체제의 파일시스템에서 관리하는 논리 페이지를 현재 할당된 물리 페이지로 매핑하는 플래시 변환 계층인 FTL을 내부에 둔다. 쓰기 연산으로 버려진 SSD 페이지는 초기화 작업을 거쳐 재활용되어야 하는데, 그 횟수에 제한이 있기 때문에 FTL은 기본인 페이지 매핑 기능 외에 쓰기 횟수를 줄일 수 있는 캐시 기능을 제공한다. 이 연구에서는 쓰기 횟수를 줄이기 위한 FTL의 캐시 방법론에 집중하여 관련된 알고리즘들을 분석하고, 쓰기 전용 캐시 전략을 제안한다. 시뮬레이터를 사용하여 쓰기 전용 캐시를 실험한 결과 최대 29%의 개선 효과를 보였다.

응력 해소 시간 변화를 통한 광전자소자용 주름구조 주기와 높이의 독립적 제어 연구 (Independent Control of Wrinkle Wavelength and Height for Optoelectronic Devices via Changing Stress Relaxation Time)

  • 구봉준;김종복
    • 접착 및 계면
    • /
    • 제23권2호
    • /
    • pp.39-43
    • /
    • 2022
  • 디스플레이, 태양전지와 같이 전기를 빛으로, 또는 빛을 전기로 변환시켜주는 광전자소자는 효율 향상을 위하여 빛의 거동 제어가 매우 중요하다. 즉, OLED의 경우 내부 빛 제어를 통해 더 많은 빛이 외부로 나갈 수 있도록 유도해 줄 때 발광효율을 향상시킬 수 있으며, 외부 빛 제어를 통해 광흡수층에서의 광경로를 증대시킬 경우 태양전지의 에너지 변환효율을 증가시킬 수 있다. 본 연구에서는 이러한 광거동 제어가 가능한 구조로서 주름구조에 대한 연구를 진행하였으며 응력 해소 시간을 제어하여 구조의 주기와 높이를 독립적으로 제어하고자 하였다. 주기와 높이의 변화가 광거동에 어떠한 영향을 미치는지 살펴보기 위하여 일정한 주기에서 높이 변화 및 유사한 높이에서 주기 변화에 따른 자외선/가시광선 분광분석(UV/Vis spectroscopy)을 실시하였으며 구조의 종횡비가 클수록 직진광의 비율이 낮고 분산광의 비율이 높음을 확인하였다. 이를 통해 광경로 변화 및 광경로 증가를 위하여 큰 종횡비의 주름구조가 요구됨을 확인할 수 있었다.

Seepage characteristics of the leaching solution during in situ leaching of uranium

  • Sheng Zeng ;Jiayin Song ;Bing Sun;Fulin Wang ;Wenhao Ye;Yuan Shen;Hao Li
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.566-574
    • /
    • 2023
  • Investigating the seepage characteristics of the leaching solution in the ore-bearing layer during the in situ leaching process can be useful for designing the process parameters for the uranium mining well. We prepared leaching solutions of four different viscosities and conducted experiments using a self-developed multifunctional uranium ore seepage test device. The effects of different viscosities of leaching solutions on the seepage characteristics of uranium-bearing sandstones were examined using seepage mechanics, physicochemical seepage theory, and dissolution erosion mechanism. Results indicated that while the seepage characteristics of various viscosities of leaching solutions were the same in rock samples with similar internal pore architectures, there were regular differences between the saturated and the unsaturated stages. In addition, the time required for the specimen to reach saturation varied with the viscosity of the leaching solution. The higher the viscosity of the solution, the slower the seepage flow from the unsaturated stage to the saturated stage. Furthermore, during the saturation stage, the seepage pressure of a leaching solution with a high viscosity was greater than that of a leaching solution with a low viscosity. However, the permeability coefficient of the high viscosity leaching solution was less than that of a low viscosity leaching solution.

토양 속 박테리아가 지하매설 X65 배관의 미생물 부식 거동에 미치는 영향 (Effect of Bacteria in Soil on Microbiologically Influenced Corrosion Behavior of Underground X65 Pipeline)

  • 최병학;한성희;김대현;김우식;김철만;최광수
    • 한국재료학회지
    • /
    • 제32권3호
    • /
    • pp.168-179
    • /
    • 2022
  • Microbiologically Influenced Corrosion (MIC) occurring in underground buried pipes of API 5L X65 steel was investigated. MIC is a corrosion phenomenon caused by microorganisms in soil; it affects steel materials in wet atmosphere. The microstructure and mechanical properties resulting from MIC were analyzed by OM, SEM/EDS, and mapping. Corrosion of pipe cross section was composed of ① surface film, ② iron oxide, and ③ surface/internal microbial corrosive by-product similar to surface corrosion pattern. The surface film is an area where concentrations of C/O components are on average 65 %/16 %; the main components of Fe Oxide were measured and found to be 48Fe-42O. The MIC area is divided into surface and inner areas, where high concentrations of N of 6 %/5 % are detected, respectively, in addition to the C/O component. The high concentration of C/O components observed on pipe surfaces and cross sections is considered to be MIC due to the various bacteria present. It is assumed that this is related to the heat-shrinkable sheet, which is a corrosion-resistant coating layer that becomes the MIC by-product component. The MIC generated on the pipe surface and cross section is inferred to have a high concentration of N components. High concentrations of N components occur frequently on surface and inner regions; these regions were investigated and Na/Mg/Ca basic substances were found to have accumulated as well. Therefore, it is presumed that the corrosion of buried pipes is due to the MIC of the NRB (nitrate reducing bacteria) reaction in the soil.

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • 국제학술발표논문집
    • /
    • The 7th International Conference on Construction Engineering and Project Management Summit Forum on Sustainable Construction and Management
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF

활성화 함수 근사를 통한 지수함수 기반 신경망 마스킹 기법 (Masking Exponential-Based Neural Network via Approximated Activation Function)

  • 김준섭;김규상;박동준;박수진;김희석;홍석희
    • 정보보호학회논문지
    • /
    • 제33권5호
    • /
    • pp.761-773
    • /
    • 2023
  • 본 논문에서는 딥러닝 분야에서 사용되는 신경망 모델, 그중에서도 다중 계층 퍼셉트론 모델에 사용되는 지수함수 기반의 활성화 함수를 근사 함수로 대체하고, 근사 함수에 마스킹을 적용함으로써 신경망 모델의 추론 과정의 전력 분석 저항성을 높이는 방법을 제안한다. 이미 학습된 값을 사용하여 연산하는 인공 신경망의 추론 과정은 그 특성상 가중치나 편향 등의 내부 정보가 부채널 공격에 노출될 위험성이 있다. 다만 신경망 모델의 활성화 함수 계층에서는 매우 다양한 함수를 사용하고, 특히 지수함수 기반의 활성화 함수에는 마스킹 기법 등 통상적인 부채널 대응기법을 적용하기가 어렵다. 따라서 본 연구에서는 지수함수 기반의 활성화 함수를 단순한 형태로 근사하여도 모델의 치명적인 성능 저하가 일어나지 않음을 보이고, 근사 함수에 마스킹을 적용함으로써 전력 분석으로부터 안전한 순방향 신경망 모델을 제안하고자 한다.

Trabeculae in the basilar venous plexus: anatomical and histological study with application to intravascular procedures

  • Viktoriya S. Grayson;Mitchell Couldwell;Arada Chaiyamoon;Juan J. Cardona;Francisco Reina;Ana Carrera;Erin P. McCormack;Kendrick Johnson;Sassan Keshavarzi;Joe Iwanaga;Aaron S. Dumont;R. Shane Tubbs
    • Anatomy and Cell Biology
    • /
    • 제56권4호
    • /
    • pp.435-440
    • /
    • 2023
  • Few studies have examined the basilar venous plexus (BVP) and to our knowledge, no previous study has described its histology. The present anatomical study was performed to better elucidate these structures. In ten cadavers, the BVP was dissected. The anatomical and histological evaluation of the intraluminal trabeculae within this sinus were evaluated. Once all gross measurements were made, the clivus and overlying BVP were harvested and submitted for histological analysis. A BVP was identified in all specimens and in each of these, intraluminal trabeculae were identified. The mean number of trabeculae per plexus was five. These were most concentrated in the upper half of the clivus and were more often centrally located. These septations traveled in a posterior to anterior direction and usually, from inferiorly to superiorly however some were noted to travel horizontally. In a few specimens the trabeculae had wider bases, especially on the posterior attachment to the meningeal layer of dura mater. More commonly, the trabeculae ended in a denticulate form at their two terminal ends. The trabeculae were on average were 0.85 mm in length. The mean width of the trabeculae was 0.35 mm. These septations were consistent with the cords of Willis as are found in the lumen of some of the other intradural venous sinuses. An understanding of the internal anatomy of the BVP can aid in our understanding of venous pathology. Furthermore, this knowledge will benefit patients undergoing interventional treatments that involve the BVP.