• Title/Summary/Keyword: Intermediate Data

Search Result 1,090, Processing Time 0.04 seconds

Measurement and Prediction of Fire and Explosion Properties of n-Ethylanilne (노말에틸아닐린의 화재 및 폭발 특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Korean Chemical Engineering Research
    • /
    • v.56 no.4
    • /
    • pp.474-478
    • /
    • 2018
  • For process safety, fire and explosion characteristics of combustible materials handled at industrial fields must be available. The combustion properties for the prevention of the accidents in the work place are flash point, fire point, explosion limit, and autoignition temperature (AIT) etc.. However, the combustion properties suggested in the Material Safety Data Sheet (MSDS) are presented differently according to the literatures. The accurate combustion properties are necessary to safely treatment, transportation and handling of flammable substances. In the chemical industries, n-ethylaniline which is widely used as a raw material of intermediate products and rubber chemicals was selected. For safe handling of n-ethyl aniline, the flash point, the fire point and the AIT were measured. The lower explosion limit (LEL)of n-ethylaniline was calculated using the lower flash point obtained in the experiment. The flash points of n- ethylaniline by using the Setaflash and Pensky-Martens closed-cup testers measured $77^{\circ}C$ and $82^{\circ}C$, respectively. The flash points of n-ethylaniline using the Tag and Cleveland open cup testers are measured $85^{\circ}C$ and $92^{\circ}C$, respectively. The AIT of the measured n-ethyl aniline by the ASTM E659 apparatus was measured at $396^{\circ}C$. The LEL of n-ethylaniline measured by Setaflash closed-cup tester at $77^{\circ}C$ was calculated to be 1.02 vol%. In this study, it was possible to predict the LEL by using the lower flash point of n-ethylaniline measured by closed-cup tester. The relationship between the ignition temperature and the ignition delay time of the n-ethylaniline proposed in this study makes it possible to predict the ignition delay time at different ignition temperatures.

Key Bit-dependent Attack on Side-Channel Analysis-Resistant Hardware Binary Scalar Multiplication Algorithm using a Single-Trace (부채널 분석에 안전한 하드웨어 이진 스칼라 곱셈 알고리즘에 대한 단일 파형 비밀 키 비트 종속 공격)

  • Sim, Bo-Yeon;Kang, Junki;Han, Dong-Guk
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.5
    • /
    • pp.1079-1087
    • /
    • 2018
  • Binary scalar multiplication which is the main operation of elliptic curve cryptography is vulnerable to the side-channel analysis. Especially, it is vulnerable to the side-channel analysis which uses power consumption and electromagnetic emission patterns. Thus, various countermeasures have been studied. However, they have focused on eliminating patterns of data dependent branches, statistical characteristic according to intermediate values, or the interrelationships between data. No countermeasure have been taken into account for the secure design of the key bit check phase, although the secret scalar bits are directly loaded during that phase. Therefore, in this paper, we demonstrate that we can extract secret scalar bits with 100% success rate using a single power or a single electromagnetic trace by performing key bit-dependent attack on hardware implementation of binary scalar multiplication algorithm. Experiments are focused on the $Montgomery-L{\acute{o}}pez-Dahab$ ladder algorithm protected by scalar randomization. Our attack does not require sophisticated pre-processing and can defeat existing countermeasures using a single-trace. As a result, we propose a countermeasure and suggest that it should be applied.

A Study on the Vertical Temperature Difference of Steel Box Girder Bridge by Field Measurement (실측에 의한 강박스거더교의 상하 온도차에 대한 연구)

  • Lee, Seong-Haeng;Park, Young-Chun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.545-551
    • /
    • 2018
  • For domestic application of the temperature gradient model proposed by foreign design standards, a specimen of steel box girder bridge was fabricated with the following dimensions: 2.0 m width, 2.0 m height and 3.0 m length. Temperature was measured using 24 temperature gauges during the summer of 2016. The reliability of the measured data was verified by comparing the measured air temperature with the ambient air temperature of the Korea Meteorological Administration. Of the measured gauges, four temperature gauges that can be compared with the temperature difference of the Euro code were selected and used to analyze the distribution of the measured temperatures at each point. The reference atmospheric temperature for the selection of the maximum temperature difference was determined by considering the standard error. Maximum and minimum temperatures were calculated from the four selected points and the resulting temperature difference was calculated. The model for the temperature difference in the steel box girder bridge was shown by graphing the temperature difference. Compared to the temperature distribution of the Euro code, the presented temperature difference model showed a temperature difference of $0.9^{\circ}C$ at the top and of $0.3^{\circ}$ to $0.4^{\circ}C$ at the intermediate part. These results suggested that the presented model could be considered relatively similar to the Euro code The calculated standard error coefficient was 2.71 to 2.84 times the standard error and represents a range of values. The proposed temperature difference model may be used to generate basic data for calculating the temperature difference in temperature load design.

Emergency Room access by Population Density and distance of Daegu Metropolitan city (대구광역시의 인구밀집과 거리에 따른 응급실 접근성)

  • Kim, Myung-Gwan;Han, Seung-Woo;Kim, Ki-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.218-223
    • /
    • 2020
  • This study examined the accessibility of emergency rooms according to the population density and distance in Daegu Metropolitan City to help improve the quality and emergency medical accessibility problems in Daegu Metropolitan City. To observe the geographical requirements, the number of population in eup, myeon, dong, available emergency, and available emergency compared to the population were mapped through the S-GIS of Statistics Korea to visualize the data based on the 3km radius. To determine the difference in accessibility to emergency rooms for each district in Daegu Metropolitan City, the data were analyzed by ANOVA and Scheffe. According to the average number of emergencies available in Daegu Metropolitan City within a 3-kilometer radius were 5.7 in Jung-gu, 5.0 in Nam-gu, 1.6 in Buk-gu, 0.4 in Dong-gu, 2.4 in Seo-gu, 0.9 in Suseong-gu, 3.5 in Dalseo-gu, and 0.1 in Dalseong-gun; there was a statistically significant difference (p<.001). The available emergency within a 3km radius and available emergency per 1,000 people were concentrated in the center. Therefore, it may be necessary to institute an urban emergency medical network by establishing a point that serves as an intermediate hub to provide emergency medical care to citizens far from the center.

Heterosis Effects on Jumping Height and Body Weight in Three-Way Rotational Crossing in Mice

  • Kurnianto, E.;Shinjo, A.;Suga, D.;Nakada, T.;Sunagawa, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.10
    • /
    • pp.1353-1358
    • /
    • 2000
  • The three-way rotational crossing experiment has been conducted to evaluate heterosis effects on jumping height and body weight. Yonakuni wild mice (Y) and two genetic groups of $CF_{{\sharp}1}$ (C) and C3H/HeNCrj (H) laboratory mice were used as materials. Reciprocal rotational crossing was made by crossing C male${\times}$Y female and Y male${\times}$C female to produce basic group designated $G_0$ and ${G_0}^{\prime}$, respectively. The females of the $G_0$ and ${G_0}^{\prime}$ were mated to the H sire to produce second generation ($G_1$ and ${G_1}^{\prime}$), and at the following generation the replacement females were mated to Y or C sire according to the basic group to produce $G_2$ to $G_3$ and ${G_2}^{\prime}$ to ${G_3}^{\prime}$. Individual jumping height data at Wk6 and body weight data at 1 (Wk1), 3 (Wk3), 6 (Wk6) and 10 (Wk10) weeks of age were analyzed. The results showed that effects of genetic group, sex and interaction of genetic group by sex were significant (p<0.01) for jumping height. For males, 55.34%~79.17% and 54.46%~78.29% of heterosis were reached at $G_1$ to $G_3$ and ${G_1}^{\prime}$ to ${G_3}^{\prime}$, respectively. While for females at $G_1$ to $G_3$ and at ${G_1}^{\prime}$ to ${G_3}^{\prime}$, heterosis effects were 61.53%~80.42% and 47.79%~85.86%, respectively. For body weight, genetic group was a significant source of variation at all ages studied. Sex effect was significant at Wk3, Wk6 and Wk10, and interaction between genetic group and sex was significant at Wk6 and Wk10 (p<0.01). C sires resulted in the highest body weight of offspring, while H sires were the intermediate and Y sires were the lightest. The significant positive and negative heterosis effects for body weight were exhibited. Crossing involved the Y sires in addition to smaller maternal effects of Y dams tended to result in small heterosis.

Species and Hybrid Identification of Genus Coreoleuciscus Species in Hwnag-ji Stream, Nakdong River Basin in Korea (낙동강 상류 황지천에 서식하는 쉬리속(genus Coreoleuciscus) 어류 집단의 종 동정 및 잡종 판별)

  • Song, Ha-Yoon;Kim, Jae-Hun;Seo, In-Young;Bang, In-Chul
    • Korean Journal of Ichthyology
    • /
    • v.29 no.1
    • /
    • pp.1-12
    • /
    • 2017
  • A natural hybrid of interspecific between the Coreoleuciscus splendidus and C. aeruginos (Cypriniformes: Cyprinidae) was captured in the Hwang-ji Stream, a tributary of the Nakdong River basin in Korea. An interspecific hybrid between C. splendidus and C. aeruginos was genetically identified based on morphological characteristics and the sequence analysis of nuclear recombination activating gene 1 (RAG1) gene (1,334 bp) and mitochondrial cytochrome c oxidase subunit 1 (CO1) gene (1,551 bp). As a result of morphological variations, the natural hybrid appeared to have an intermediate character between two parental species (C. splendidus and C. aeruginos) in three variations of black array (s) on dorsal, caudal and anal fin rays. Phylogenetic analysis inferred from RAG1 and CO1 sequence data revealed that Coreoleuciscus populations from Hwang-ji stream consist of two pure Coreoleuciscus species and a hybrid individual group. The individuals were clearly identified the cross and reciprocal hybrid by CO1 gene analysis. In RAG1 gene, 13 nucleotide variation loci were detected and the hybrid individuals displayed the double peaks of sequence chromatograms at the 9 diagnostic positions. In this study, molecular data and morphological variations were clearly demonstrated that hybridization did occur between C. splendidus and C. aeruginos. However, F2 hybrid generation and reproductive capacity of F1 hybrid individuals were not demonstrated.

Dosimetric Characteristics of the KCCH Neutron Therapy Facility (원자력병원 중성자선치료기의 물리적특성)

  • Yoo Seong Yul;Noh Sung Woo;Chung Hyun Woo;Cho Chul Koo;Koh Kyoung Hwan;Bak Joo Shik;Eenmaa Juri
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.85-91
    • /
    • 1988
  • For the physical characterization of neutron beam, dosimetric measurements had been performed to obtain physical data of KCCH cyclotron-produced neutrons for clinical use. The results are presented and compared with the data of other institutions from the literatures. The central axis percent depth dose, build-up curves and open and wedge isodose curve values are intermediate between that of a 4 and 6 MV X-rays. The build-up level of maximum dose was at 1.35cm and entrance dose was approximately $40\%$. Flatness of the beam was $9\%$ at Dmax and less $than{\pm}3\%$ at the depth of $80\%$ isodose line. Penumbra begond the $20\%$ line is wider than corresponding photon beam. The output factors ranged 0.894 for $6\times6cm$ field to 1.187 for $30\times30cm$ field. Gamma contamination of neutron beam was $4.9\%$ at 2 cm depth in $10\times10cm$ field.

  • PDF

A Grounded Theory Approach to the Comfort Experience of Hospitalized Patients (입원대상자의 안위경험에 대한 근거이론적 접근)

  • 김경희;김금순;강규숙;강현숙;김원옥;백훈정;원종순;임난영;정인숙
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.3
    • /
    • pp.750-763
    • /
    • 2000
  • This study is based on grounded theory methodology by Strauss & Corbin(1998). Ten hospitalized subjects were interviewed for data collection. In the process of data analysis, 'acceptance' is found to be the causal condition, while 'health professionals' skillfulness', 'ward environment', 'history of hospitalization', and 'general conditions' were identified as context, 'felling of relief' as the core phenomenon, 'self-efficacy', 'support of others', and 'life style' as the intermediate situation, 'passive reaction', 'alternative reaction' and 'active reaction' as the strategy and 'stabilization', 'satisfaction', 'hope' and 'carrying out' as consequences. 'Feeling of relief' is found to go through the three stages of recognition-generation-maintenance after the five different patterns. 1) In case the health professionals are skillful, the ward environment is favorable, the general conditions of the patients improved and as a result the feeling of relief is strong, during the first hospitalization, the self-efficacy of the subjects tends to be strong. They proceed toward the goal set for themselves with a renewed hope and active or alternative reaction toward the feeling of relief. 2) The subjects tend to proceed toward the goal set for themselves with a renewed hope and active and alternative reaction toward the feeling of relief in case health professionals are skillful, the ward environment is favorable the general conditions of the subjects improved, self-efficacy is strong, and lifestyle is autonomous, during the second hospitalization even though support of others is merely superficial. 3) The subjects tend to stabilize, and satisfy themselves with the given situation with passive and alternative reaction to the feeling of relief in case health professionals are skillful and the ward environment is favorable but the general conditions worsened and accordingly the feeling of relief, is weak and life style is dependent during the second hospitalization although the subjects' self-efficacy is strong and support of others is specific. 4) The subjects tend to stabilize and satisfy themselves with the given situation with passive and alternative reaction to the feeling of relief in case health professionals are unskillful the ward environment is unfavorable, the general conditions improved, support of others is specific but life style is dependent and self-efficacy is weak during the first hospitalization. 5) The subjects tend to stabilize and satisfy themselves with the given situation in case health professionals are unskillful the ward environment is unfavorable but the general conditions improved support of others is specific and as a result self-efficacy is strong but life style is dependent.

  • PDF

Classification of Atmospheric Vertical Environment Associated with Heavy Rainfall using Long-Term Radiosonde Observational Data, 1997~2013 (장기간(1997~2013) 라디오존데 관측 자료를 활용한 집중호우 시 연직대기환경 유형 분류)

  • Jung, Sueng-Pil;In, So-Ra;Kim, Hyun-Wook;Sim, JaeKwan;Han, Sang-Ok;Choi, Byoung-Choel
    • Atmosphere
    • /
    • v.25 no.4
    • /
    • pp.611-622
    • /
    • 2015
  • Heavy rainfall ($>30mm\;hr^{-1}$) over the Korean Peninsula is examined in order to understand thermo-dynamic characteristics of the atmosphere, using radiosonde observational data from seven upper-air observation stations during the last 17 years (1997~2013). A total of 82 heavy rainfall cases during the summer season (June-August) were selected for this study. The average values of thermo-dynamic indices of heavy rainfall events are Total Precipitable Water (TPW) = 60 mm, Convective Available Potential Energy (CAPE) = $850J\;kg^{-1}$, Convective Inhibition (CIN) = $15J\;kg^{-1}$, Storm Relative Helicity (SRH) = $160m^2s^{-2}$, and 0~3 km bulk wind shear = $5s^{-1}$. About 34% of the cases were associated with a Changma front; this pattern is more significant than other synoptic pressure patterns such as troughs (22%), migratory cyclones (15%), edges of high-pressure (12%), typhoons (11%), and low-pressure originating from Changma fronts (6%). The spatial distribution of thermo-dynamic conditions (CAPE and SRH) is similar to the range of thunderstorms over the United States, but extreme conditions (supercell thunderstorms and tornadoes) did not appear in the Korean Peninsula. Synoptic conditions, vertical buoyancy (CAPE, CIN), and wind parameters (SRH, shear) are shown to discriminate among the environments of the three types. The first type occurred with high CAPE and low wind shear by the edge of the high pressure pattern, but Second type is related to Changma front and typhoon, exhibiting low CAPE and high wind shear. The last type exhibited characteristics intermediate between the first and second types, such as moderate CAPE and wind shear near the migratory cyclone and trough.

Hydrogeological characteristics of the LILW disposal site (처분부지의 수리지질 특성)

  • Kim, Kyung-Su;Kim, Chun-Soo;Bae, Dae-Seok;Ji, Sung-Hoon;Yoon, Si-Tae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.245-255
    • /
    • 2008
  • Korea Hydro and Nuclear Power Company(KHNP) conducted site investigations for a low and intermediate-level nuclear waste repository in the Gyeong Ju site. The site characterization work constitutes a description of the site, its regional setting and the current state of the geosphere and biosphere. The main objectives of hydogeological investigation aimed to understand the hydrogeological setting and conditions of the site, and to provide the input parameters for safety evaluation. The hydogeological characterization of the site was performed from the results of surface based investigations, i.e geological mapping and analysis, drilling works and hydraulic testing, and geophysical survey and interpretation. The hydro-structural model based on the hydrogeological characterization consists of one-Hydraulic Soil Domain, three-Hydraulic Rock Domains and five-Hydraulic Conductor Domains. The hydrogeological framework and the hydraulic values provided for each hydraulic unit over a relevant scale were used as the baseline for the conceptualization and interpretation of flow modeling. The current hydrogeological characteristics based on the surface based investigation include some uncertainties resulted from the basic assumption of investigation methods and field data. Therefore, the reassessment of hydrostructure model and hydraulic properties based on the field data obtained during the construction is necessitated for a final hydrogeological characterization.

  • PDF