• 제목/요약/키워드: Interleaved converter

검색결과 264건 처리시간 0.024초

Analysis, Design, and Implementation of a Zero-Voltage-Transition Interleaved Boost Converter

  • Ting, Naim Suleyman;Sahin, Yakup;Aksoy, Ismail
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.41-55
    • /
    • 2017
  • This study proposes a novel zero voltage transition (ZVT) pulse width modulation (PWM) DC-DC interleaved boost converter with an active snubber cell. All the semiconductor devices in the converter turn on and off with soft switching to reduce the switching power losses and improve the overall efficiency. Through the interleaved approach, the current stresses of the main devices and the ripple of the output voltage and input current are reduced. The main switches turn on with ZVT and turn off with zero voltage switching (ZVS). The auxiliary switch turns on with zero current switching (ZCS) and turns off with ZVS. In addition, the snubber cell does not create additional current or voltage stress on the main switches and main diodes. The proposed converter can smoothly achieve soft switching characteristics even under light load conditions. The theoretical analysis and operating stages of the proposed converter are made for the D > 50% and D < 50% modes. Finally, a prototype of the proposed converter is implemented, and the experimental results are given in detail for 500 W and 50 kHz. The overall efficiency of the proposed converter reached 95.5% at nominal output power.

Analysis, Design and Implementation of a New Chokeless Interleaved ZVS Forward-Flyback Converter

  • Taheri, Meghdad;Milimonfared, Jafar;Namadmalan, Alireza;Bayat, Hasan;Bakhshizadeh, Mohammad Kazem
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.499-506
    • /
    • 2011
  • This paper presents an interleaved active-clamping zero-voltage-switching (ZVS) forward-flyback converter without an output choke. The presented topology has two active-clamping circuits with two separated transformers. Because of the interleaved operation of the converter, the output current ripple will be reduced. The proposed converter can approximately share the total load current between the two secondaries. Therefore, the transformer copper loss and the rectifier diodes conduction loss can be decreased. The output capacitor is made of two series capacitors which reduces the peak reverse voltage of the rectifier diodes. The circuit has no output inductor and few semiconductor elements, such that the adopted circuit has a simpler structure, a lower cost and is suitable for high power density applications. A detailed analysis and the design of this new converter are described. A prototype converter has been implemented and experimental results have been recorded with an ac input voltage of 85-135Vrms, an output voltage of 12V and an output current of 16A.

직류링크 전류를 이용한 인터리브드 양방향 컨버터의 상전류 불균형 보상 방법 (Compensation of Unbalanced Phase Currents in Interleaved Bi-directional Converter with DC Link Current Sensed)

  • 한정호;최유현;송중호
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.90-97
    • /
    • 2014
  • This paper presents a compensation method of unbalanced phase currents in interleaved bi-directional converters. Phase currents in interleaved bi-directional converter are apt to be unbalanced due to circuit parameter error and switch operation difference. This problem causes the switch element failure and the reduced efficiency of the converter. Therefore, it is necessary that a certain balance control algorithm is provided in interleaved bi-directional converter system. In this paper, a balance control algorithm based on the circular chain control method is proposed. Further, in order to reduce the number of phase current sensors, this paper shows a simple method in which phase currents can be extracted indirectly through a DC-link current sensor in both charging and discharging modes. The validity and the effectiveness of the proposed phase currents balance control algorithm are illustrated through the simulation results.

다상부스트 컨버터를 적용한 태양광 발전시스템 (Photovoltaic System with Multi-Phase Interleaved Boost Converter)

  • 이주혁;장수진;차길로;원충연;정용채
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.59-62
    • /
    • 2007
  • In this paper, we composed solar generation system with multi-phase interleaved boost converter Solar generated voltage is low, so it has need of the boost power conversion device for supply power to normal load. The multi-phase interleaved boost converter is easy to boost voltage and it can be reduced both input current ripple and output voltage ripple because it is composed with multi-phase. We simulated and tested multi-phase interleaved boost converter applied three-phase.

  • PDF

분산 전원장치를 위한 중첩형 컨버터의 성능 비교 (Performances Comparison of Interleaved Converter for Distributed Power System)

  • 문건우;윤석호;김용
    • 조명전기설비학회논문지
    • /
    • 제12권3호
    • /
    • pp.37-44
    • /
    • 1998
  • 본 논문에서는 분산전원 장치에 사용되는 증첩형 액티브클램프 ZVS 포워드 컨버터와 ZVS 하프 브리지(Half bbridge) 컨버터의 동작특성과 효율을 비교하였다. 또한 중첩형 액티브클램프 ZVS 포워드 컨버터의 전류모드 제어회로 설계 방법을 제시하였고, 게이트 구동회로를 간단히 하기 위해 N-P M OSFETs 로 조합된 액티브클램프 기법을 제안하여 50~100% 부하 범위에서 약 90%의 효율을 얻을 수 있었다.

  • PDF

A New Interleaved Double-Input Three-Level Boost Converter

  • Chen, Jianfei;Hou, Shiying;Sun, Tao;Deng, Fujin;Chen, Zhe
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.925-935
    • /
    • 2016
  • This paper proposes a new interleaved double-input three-level Boost (DITLB) converter, which is composed of two boost converters indirectly in series. Thus, a high voltage gain, together with a low component stress and a small input current ripple due to the interleaved control scheme, is achieved. The operating principle of the DITLB converter under the individual supplying power (ISP) and simultaneous supplying power (SSP) mode is analyzed. In addition, closed-loop control strategies composed of a voltage-current loop and a voltage-balance loop, have been researched to make the converter operate steadily and to alleviate the neutral-point imbalance issue. Experimental results verify correctness and feasibility of the proposed topology and control strategies.

불연속 전류모드에서의 다상 교호 강압컨버터의 정상상태 해석 및 모델링 (Modeling and Steady-state Analysis of the Multi-Phase Interleaved Buck converter in Discontinuous Inductor Current Mode)

  • 장성동;장은승;정세교;신휘범;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.506-510
    • /
    • 2004
  • A multi-phase interleaved buck converter is used to reduce current ripples and filter size of a power supply. This paper addresses the modelling and steady-state analysis of the multi-phase interleaved buck converter operated in discontinuous inductor current mode. The model is derived using an averaging technique in steady state. The do voltage ratio and the range of the discontinuous inductor current mode(DICM) and the continuous output current mode(COCM) are derived from the averaged state-space model. In addition, the efficiency is investigated according to the number of phase.

  • PDF

다상 DC-DC 컨버터의 입력 전류 리플 저감 제어 알고리즘 (Input Current Ripple Reduction Algorithm for Interleaved DC-DC Converter)

  • 주동명;김동희;이병국
    • 전력전자학회논문지
    • /
    • 제19권3호
    • /
    • pp.220-226
    • /
    • 2014
  • Input current ripple and harmonic components of the power device are main causes of electromagnetic interference (EMI). Although the discontinuous conduction mode (DCM) operation can reduce harmonic components of the power device by reducing reverse recovery current of diode and turn-off voltage spikes of the switch, input current ripple increases due to high peak to peak inductor current. Therefore, in this paper, frequency control algorithm is proposed to reduce the input current ripple of DCM operated interleaved boost converter. In the proposed algorithm, duty ratio is fixed either 0.33 or 0.67 to minimize the input current ripple and the switching frequency is controlled according to operating conditions. 600 W 3-phase interleaved boost converter prototype system is built to verify proposed algorithm.

인터리브 방식을 이용한 액티브 클램핑 포워드 컨버터에 관한 연구 (A Study on the Interleaved Active-Clamping Forward Converter)

  • 정재엽;김용;권순도;배진용;이동현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.156-160
    • /
    • 2009
  • This paper presents the interleaved active-clamping ZVS(Zero Voltage Switching) forward converter, which is mainly composed of two active-clamping forward converters. Only two switches are required, and each one is the auxiliary switch for the other. The circuit complexity and cost are thus reduced. The leakage inductance of the transformer or an additional resonant inductance is employed to achieve ZVS during the dead times. The duty cycles are not limited to be equal and within 50%. The complementary switching and the resulted interleaved output inductor currents diminish the current ripple in output capacitors. Accordingly, the smaller output chokes and capacitors lower the converter volume and increase the power density. Detailed analysis and design of this new interleaved active-clamping forward converter are described.

  • PDF

Modulated Carrier Control for Interleaved Continuous Conduction Mode(CCM) Boost Power Factor Correction Converter

  • Kim, Hye-jin;Choi, Kyu-sik;Cho, B.H.;Choi, Hang-seok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.195-196
    • /
    • 2012
  • In recent years, in an effort to improve the efficiency and the power density of the front-end power factor correction(PFC), the interleaving of multiple converter is employed. The conventional interleaved continuous conduction mode(CCM) boost PFC converter requires input and output voltage sensing and three current sensing to obtain current balancing between modules. In this paper, the interleaved CCM PFC converter based on modulated carrier control is proposed. With the proposed method, two phase interleaved PFC can be realized simply without line voltage sensing resistor and can achieve current balancing without additional current sensing resistor on common return path. The simulation studies are carried out to verify the effectiveness of the proposed control scheme.

  • PDF