Review of Aging Management for Concrete Silo Dry Storage Systems

  • Donghee Lee;Sunghwan Chung;Yongdeog Kim;Taehyung Na
    • 방사성폐기물학회지
    • /
    • 제21권4호
    • /
    • pp.531-541
    • /
    • 2023
  • The Wolsong Nuclear Power Plant (NPP) operates an on-site spent fuel dry storage facility using concrete silo and vertical module systems. This facility must be safely maintained until the spent nuclear fuel (SNF) is transferred to an external interim or final disposal facility, aligning with national policies on spent nuclear fuel management. The concrete silo system, operational since 1992, requires an aging management review for its long-term operation and potential license renewal. This involves comparing aging management programs of different dry storage systems against the U.S. NRC's guidelines for license renewal of spent nuclear fuel dry storage facilities and the U.S. DOE's program for long-term storage. Based on this comparison, a specific aging management program for the silo system was developed. Furthermore, the facility's current practices-periodic checks of surface dose rate, contamination, weld integrity, leakage, surface and groundwater, cumulative dose, and concrete structure-were evaluated for their suitability in managing the silo system's aging. Based on this review, several improvements were proposed.

경수로 사용후핵연료 건식 중간저장시설의 격납건물 크기에 따른 건물 벽면에서의 방사선량률 추이 예비 분석 (Preliminary Analysis of Dose Rate Variation on the Containment Building Wall of Dry Interim Storage Facilities for PWR Spent Nuclear Fuel)

  • 서명환;윤정현;차길용
    • Journal of Radiation Protection and Research
    • /
    • 제38권4호
    • /
    • pp.189-193
    • /
    • 2013
  • 경수로 사용후핵연료 건식 중간저장시설 격납건물 크기에 따른 방사선량률 추이 분석을 위하여 격납건물 외부 벽면에서의 추정연간선량을 계산하였다. ORIGEN-ARP를 사용하여 농축도 4.5 wt%, 연소도 45,000 MWd/MTU 냉각기간 10년인 사용후핵연료를 대상으로 선원항을 생산하였으며, MCNP 코드를 사용하여 저장시설 및 격납건물에 대한 모델링 및 선량률 계산을 수행하였다. 연간선량은 격납건물 외부 벽면에서의 값으로 계산하였으며, 격납건물 벽과 최외곽 배열의 저장용기와의 간격을 50 m 이상으로 설정할 경우 10CFR72에서 제시하는 연간선량인 0.25 mSv 이하의 값이 계산되었다.

Development of a Probabilistic Safety Assessment Framework for an Interim Dry Storage Facility Subjected to an Aircraft Crash Using Best-Estimate Structural Analysis

  • Almomani, Belal;Jang, Dongchan;Lee, Sanghoon;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • 제49권2호
    • /
    • pp.411-425
    • /
    • 2017
  • Using a probabilistic safety assessment, a risk evaluation framework for an aircraft crash into an interim spent fuel storage facility is presented. Damage evaluation of a detailed generic cask model in a simplified building structure under an aircraft impact is discussed through a numerical structural analysis and an analytical fragility assessment. Sequences of the impact scenario are shown in a developed event tree, with uncertainties considered in the impact analysis and failure probabilities calculated. To evaluate the influence of parameters relevant to design safety, risks are estimated for three specification levels of cask and storage facility structures. The proposed assessment procedure includes the determination of the loading parameters, reference impact scenario, structural response analyses of facility walls, cask containment, and fuel assemblies, and a radiological consequence analysis with dose-risk estimation. The risk results for the proposed scenario in this study are expected to be small relative to those of design basis accidents for best-estimated conservative values. The importance of this framework is seen in its flexibility to evaluate the capability of the facility to withstand an aircraft impact and in its ability to anticipate potential realistic risks; the framework also provides insight into epistemic uncertainty in the available data and into the sensitivity of the design parameters for future research.

경수로 사용후핵연료 건식 중간저장시설에 대한 예비 방사선 영향 평가 (Preliminary Assessment of Radiation Impact from Dry Storage Facilities for PWR Spent Fuel)

  • 김태만;백창열;차길용;이우교;김순영
    • Journal of Radiation Protection and Research
    • /
    • 제37권4호
    • /
    • pp.197-201
    • /
    • 2012
  • 경수로 사용후핵연료 중간저장시설의 부지면적을 산출하기 위하여 콘크리트 저장시설 개념모델의 연간선량을 계산하였다. 초기농축도 4.5 wt%, 연소도 45,000 MWd/MTU, 냉각기간 10년인 사용후핵연료를 대상으로 ORIGEN-ARP를 사용하여 선원항을 생산하였으며, MCNP 코드를 사용하여 저장시설에 대한 모델링 및 방사선차폐계산을 수행하였다. 연간선량은 저장시설의 용량별로 계산하였으며, 중앙집중식 저장시설의 경우, 반경 700 m 이상에서 10CFR72에서 권고하는 통제구역 경계에서의 연간선량 기준 0.25 mSv를 만족하였다.

Analysis of Characteristics of Spent Fuels on Long-Term Dry Storage Condition

  • Yoon, Suji;Park, Kwangheon;Yun, Hyungju
    • 방사성폐기물학회지
    • /
    • 제19권2호
    • /
    • pp.205-214
    • /
    • 2021
  • Currently, the interim storage pools of spent fuels in South Korea are expected to become saturated from 2024. It is required to prepare an operation plan of a domestic dry storage facility during a long-term period, with the researches on safety evaluation methods. This study modified the FRAPCON code to predict the spent fuel integrity evaluation such as the axial cladding temperature, the hoop stress and hydrogen distribution in dry storage. The cladding temperature in dry storage was calculated using the COBRA-SFS code with the burnup information which was calculated using the FRAPCON code. The hoop stress was calculated using the ideal gas equation with spent fuel information such as rod internal pressure. Numerical analysis method was used to calculate the degree of hydrogen diffusion according to the hydrogen concentration and temperature distribution during a dry storage period. Before 50 years of dry storage, the cladding temperature and hoop stress decreased rapidly. However, after 50 years, they decreased gradually and the cladding temperature was below 400 K. The initial temperature distribution and hydrogen concentration showed a parabolic line, but hydrogen was transferred by the hydrogen concentration and temperature gradient over time.

PWR 사용후핵연료 중간저장시설의 몬테칼로 차폐해석 방법에 대한 계산효율성 개선방안 연구 (Development for Improvement Methodology of Radiation Shielding Evaluation Efficiency about PWR SNF Interim Storage Facility)

  • 김태만;서명환;조천형;차길용;김순영
    • Journal of Radiation Protection and Research
    • /
    • 제40권2호
    • /
    • pp.92-100
    • /
    • 2015
  • 경수로 사용후핵연료 건식 중간저장시설의 방사선영향평가 효율성 개선을 목적으로 '선원항 지정방법에 따른 민감도 평가', '2-Step 계산'기법 개발 및 '냉각기간 이득효과' 적용에 따른 방사선 영향평가를 수행하였다. 본 연구에서는 저장건물의 용기배열 순서에 따라 순차적으로 선원항을 지정하여 직접선량에 미치는 민감도를 평가하였으며, 차폐건물 외벽에서의 방사선량은 내벽과 인접한 최근접 2개 열에 의한 영향이 지배적임을 확인하였다. 또한, 저장시설에 차폐 건물이 도입될 경우, 막대한 전산해석 시간을 감소시키기 위해 '2-Step 계산'기법을 수립하여 평가한 결과는 절반가량의 해석시간으로 직접(1-Step) 계산결과와 유사한 결과를 도출하였다. 마지막으로, 저장시설에 순차적으로 저장되는 저장용기의 보관기간을 사용후핵연료의 실제 냉각기간을 적용하면 건물 외벽에서의 방사선량이 냉각기간을 모두 동일하게 설정한 계산값에 비해 40% 정도 낮게 평가됨을 확인하였다. 본 연구는 중간저장시설의 방사선 영향평가를 위한 몬테칼로 차폐해석 방법의 효율성을 향상시키고자 수행되었으며, 좀 더 다양한 사례에 대한 평가를 통하여 신뢰성을 향상시킨다면 저장시설의 설계 및 부지경계 기준설정에 활용할 수 있을 것이다.

사용후핵연료 운반용기 및 건식저장 기술 동향 (Technology Trends in Spent Nuclear Fuel Cask and Dry Storage)

  • 신중철;양종대;성운학;류승우;박영우
    • 한국압력기기공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.110-116
    • /
    • 2020
  • As the management plan for domestic spent nuclear fuel is delayed, the storage of the operating nuclear power plant is approaching saturation, and the Kori 1 Unit that has reached its end of operation life is preparing for the dismantling plan. The first stage of dismantling is the transfer of spent nuclear fuel stored in storage at plants. The spent fuel management process leads to temporary storage, interim storage, reprocessing and permanent disposal. In this paper, the technical issues to be considered when transporting spent fuel in this process are summarized. The spent fuels are treated as high-level radioactive waste and strictly managed according to international regulations. A series of integrity tests are performed to demonstrate that spent fuel can be safely stored for decades in a dry environment before being transferred to an intermediate storage facility. The safety of spent fuel transport container must be demonstrated under normal transport conditions and virtual accident conditions. IAEA international standards are commonly applied to the design of transport containers, licensing regulations and transport regulations worldwide. In addition, each country operates a physical protection system to reduce and respond to the threat of radioactive terrorism.

건식저장조건의 사용후핵연료 콘크리트 저장용기 예비 방사선 차폐 평가 (Preliminary Shielding Analysis of the Concrete Cask for Spent Nuclear Fuel Under Dry Storage Conditions)

  • 김태만;도호석;조천형;고재훈
    • 방사성폐기물학회지
    • /
    • 제15권4호
    • /
    • pp.391-402
    • /
    • 2017
  • 한국원자력환경공단에서는 국내 경수로 원전에서 발생된 사용후핵연료를 건식으로 저장할 수 있는 콘크리트 용기를 개발하였다. 본 저장용기는 사용후핵연료가 건식환경에서 장기간 저장되는 동안 용기 및 사용후핵연료의 건전성이 유지되며, 방사선량률이 저장시설의 설계기준을 초과하지 않도록 설계되어야 한다. 특히, 저장시설은 정상 및 사고조건에서 적절한 방사선 방호를 위한 차폐설계가 이루어져야 한다. 이를 위해 본 연구에서는 미국 10CFR72 및 10CFR20의 기술기준과 NRC의 표준 심사지침 NUREG-1536에서 제시한 평가방법에 따라 건식저장조건하에서 단일 콘크리트용기 및 $2{\times}10$ 용기배열조건의 선량율을 평가하였다. 평가결과, 일반인에 대한 연간선량 한도인 0.25 mSv를 만족하는 통제구역 경계까지의 거리는 약 230 m로 도출되었다. 콘크리트 저장용기의 설계사고는 $2{\times}10$ 배열의 저장시설에서 한 개의 저장용기가 이송 중 전도사고가 발생하여 용기의 바닥면이 통제구역 경계로 향하는 상황으로 가정하였다. 전도된 저장용기의 바닥면으로 부터 100 m 및 230 m 지점에서 각각 12.81 mSv 및 1.28 mSv로 평가되었다. 본 연구를 통해 건식저장조건에서 콘크리트 저장용기 및 저장시설은 적절하게 평가된 통제구역경계까지의 거리가 확보된다면 방사선적 안전성이 유지됨을 확인할 수 있었다. 본 평가결과만으로 건식환경의 저장용기(시설) 설계에 직접 적용하기는 어렵겠으나, 향후 '국가 고준위폐기물 관리 전략'에 근거한 원전내 저장시설 또는 중간저장 시설의 설계 및 운영에 유용한 자료가 될 것으로 사료된다.

원전부지내 사용후핵연료 건식저장기술 분석 (Technology for AR Dry Storage of Spent Fuel)

  • 이흥영;윤석중;이익환;서기석
    • Journal of Radiation Protection and Research
    • /
    • 제21권4호
    • /
    • pp.313-327
    • /
    • 1996
  • 원전부지내(AR) 사용후핵연료 건식저장방식으로 횡형콘크리트 모듈방식, 금속 저장용기 방식, 콘크리트 저장용기 방식, 수송저장 겸용용기 방식 및 다목적용기 방식 등이 있다. 이중다목적용기 방식을 제외한 다른 방식들은 각각 운영인허가를 받아 이미 세계 각 국에서 사용후핵연료 AR 건식저장에 사용되고 있으며 다목적용기 방식도 최근 개발을 활발히 진행하고 있는 상태이다. AR 건식저장 시설을 운영하고 있거나 추진중인 나라는 미국, 일본, 독일, 캐나다, 스페인, 체코, 스위스 등으로 AR 건식저장을 거쳐 중간저장이나 재처리시설로 수송하는 방식을 채택하고 있다. 우리나라의 경우 월성에서 콘크리트 Silo 건식저장을 이미 사용하고 있으며 일부 다른 원자로도 사용후핵연료 저장능력이 한계에 도달하고 있는 현실을 감안할 때 AR 임시 저장은 불가피한 것으로 여겨진다. 본 보고서에서는 고리를 비롯한 국내원전에 적용 가능한 외국의 AR 저장 시스템 각각에 대하여 설계특성, 설계요건, 기술기준 및 현황 등을 논의하였다. 대부분의 경우 저장용기 인허가 기간은 20년으로 제한하고 있으며 전 수명기간동안 재질의 건전성, 밀봉유지 등이 중요하게 요구되고 있다.

  • PDF