Abstract
Annual dose on the containment building wall of the interim storage facility at normal condition was calculated to estimate the dose rate transition of the facility of PWR spent nuclear fuel. In this study, source term was generated by ORIGEN-ARP with 4.5 wt% initial enrichment, 45,000 MWd/MTU burnup and 10 years cooling time. Modeling of the storage facility and the containment building and radiation shielding evaluations were conducted by MCNP code depending on the distance between the wall and the facility in the building. In the case of the centralized storage system, the distance required for the annual dose rate limit from 10CFR72 was estimated to be 50 m.
Keywords
Annual dose rate; 10CFR72; MCNP; PWR spent nuclear fuel; Interim storage facility; Containment building;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 사용후핵연료 수송.저장 시스템 상용화 기술개발 1단계보고서. 한국원자력환경공단. 2011.
2 Standardized NUHOMS$(R)$ horizontal modular storage system for irradiated nuclear fuel final safety analysis report volume 4 of 4. Rev.8, TRANSNUCLEAR. 2004.
3 Holtec International final safety analysis report for the HI-STORM 100 cask system. Holtec; Holtec International Holtec Center. 2010.
4 10CFR72.104. Criteria for radioactive materials in effluents and direct radiation from an ISFSI or MRS. 2006.
5 ORIGEN-ARP: Automatic rapid processing for spent fuel depletion, decay, and source term analysis. Ver.6. Oak Ridge National Laboratory. 2005.
6 김태만, 백창열, 차길용, 김순영, 이우교. 경수로 사용후핵연료 건식 중간저장시설에 대한 예비 방사선 영향 평가. 방사선방어학회지. 2012;37(4):197-201.   과학기술학회마을
7 Standard review plan for spent fuel dry storage systems at a general license facility. NUREG-1536. U.S Nuclear Regulatory Commission. 2010.
8 MCNP - A general Monte Carlo N-particle transport code version 5 (Vols. I-III). Los Alamos National Laboratory. 2003.
9 Annals of the ICRP - Conversion coefficients for use in radiological protection against external radiation. ICRP Publication 74. ICRP. 1996.