• Title/Summary/Keyword: Interference Range

Search Result 645, Processing Time 0.028 seconds

Hydrogeology and Vulnerability of Groundwater Contamination of a Mountainous Area in Kangwon Province (강원도 흥호리 지역 암반대수층의 수리지질 및 지하수 오염취약성 예비조사)

  • 이진용;이강근;정형재;배광옥
    • The Journal of Engineering Geology
    • /
    • v.10 no.1
    • /
    • pp.27-38
    • /
    • 2000
  • We hydrogeologically studied a mountainous area and its vulnerability to groundwater contamination. Groundwater flow and recharge occur mainly through a network of fractures in this areaTransmissivity and storativity obtained from slug, slug interference, and pumping tests range from 3.2$\times$10$^{-3}$ to 2.0$\times$10$^{-2}$$m^2$/min and 1.3$\times$10$^{-7}$ to 9.15$\times$10$^{-4}$, respectively. The groundwater was contaminated bylivestock activities in the upgradient. The groundwater in the downgradient residential area wasthreatened by the upgradient livestock activities.

  • PDF

Electrochemical Non-Enzymatic Glucose Sensor based on Hexagonal Boron Nitride with Metal-Organic Framework Composite

  • Ranganethan, Suresh;Lee, Sang-Mae;Lee, Jaewon;Chang, Seung-Cheol
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.379-385
    • /
    • 2017
  • In this study, an amperometric non-enzymatic glucose sensor was developed on the surface of a glassy carbon electrode by simply drop-casting the synthesized homogeneous suspension of hexagonal boron nitride (h-BN) nanosheets with a copper metal-organic framework (Cu-MOF) composite. Comprehensive analytical methods, including field-emission scanning electron microscopy (FE-SEM), Fourier-transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), cyclic voltammetry, electrochemical impedance spectroscopy, and amperometry, were used to investigate the surface and electrochemical characteristics of the h-BN-Cu-MOF composite. The FE-SEM, FT-IR, and XRD results showed that the h-BN-Cu-MOF composite was formed successfully and exhibited a good porous structure. The electrochemical results showed a sensor sensitivity of $18.1{\mu}A{\mu}M^{-1}cm^{-2}$ with a dynamic linearity range of $10-900{\mu}M$ glucose and a detection limit of $5.5{\mu}M$ glucose with a rapid turnaround time (less than 2 min). Additionally, the developed sensor exhibited satisfactory anti-interference ability against dopamine, ascorbic acid, uric acid, urea, and nitrate, and thus, can be applied to the design and development of non-enzymatic glucose sensors.

Recent Studies on Development of Transgenic Plants Induced Root-Knot Nematode Resistance by RNA Interference Suppression of Nematode Genes and Nematode Prevention (뿌리혹선충 유전자의 RNA 간섭 억제에 의한 선충저항성 식물 개발 및 선충방제의 최근 연구 동향)

  • Hahn, Bum-Soo
    • Research in Plant Disease
    • /
    • v.16 no.1
    • /
    • pp.10-20
    • /
    • 2010
  • Root-knot nematodes cause billions of dollars in crop losses annually have a broad range of host over 2,000 species of plants. These nematodes are known as obligate, sedentary endo-parasites in a plant host to feed upon to complete their life cycle. To prevent the plant parasitic nematode, methyl bromide was widely applied as a soil fumigant. Other strategies to prevent or control nematodes involve RNAi-mediated suppression, R gene transformation, natural products or chemical treatments, the expression of peptide or proteins in susceptible plants, and others. Over the last decade, the entry in GenBank for Meloidogyne reveals 73,340 ESTs and recently two complete Meloidogyne spp. genomes sequences have simultaneously been presented by two groups. Recent works have demonstrated the effect of RNAi suppression to nematode target genes. These results will provide novel members of genes as a foundation for studies focused on understanding the function of M. incognita nematode genes as well as for the development of novel target genes for parasite control. Thus the successful development of biotechnology-derived plants with nematode resistance will result in large yield benefits for producers as well as environmental benefits and will accelerate the research related to pathogensresistant crops.

Determination of $Cu^{2+}$ by Lophine Chemiluminescence

  • Kim Young-Sun;Karim Mohammad Mainul;Lee Sang-Hak;Choi Kyoung-Hye;Choi Jong-Ha;Lee Sung-Ho
    • Journal of Photoscience
    • /
    • v.12 no.3
    • /
    • pp.137-141
    • /
    • 2005
  • The chemiluminescence reaction of lophine with $H_2O_2$ in alkaline solution has been investigated for use in determination of $Cu^{2+}$ ions. The observed chemiluminescence intensity is found to be a function of the concentration of $Cu^{2+}$. Under the optimum reagent concentrations such as $4{\times}10^{-4}M$ lophine, 0.8 M KOH, 0.2M $H_2O_2,{\lambda}_{em}$, 533nm, the linear range and the detection limit were found to be 0.048ug/ml-48.32ug/ml (R=0.99897) and 0.005ulg/ml respectively. Relative standard deviation for five determinations of 24.16ug/ml $Cu^{2+}$ is 2.35%. The interference from other species was investigated. The proposed method was applied to the determination of $Cu^{2+}$ in different water samples.

  • PDF

Wind-tunnel study of wake galloping of parallel cables on cable-stayed bridges and its suppression

  • Li, Yongle;Wu, Mengxue;Chen, Xinzhong;Wang, Tao;Liao, Haili
    • Wind and Structures
    • /
    • v.16 no.3
    • /
    • pp.249-261
    • /
    • 2013
  • Flexible stay cables on cable-stayed bridges are three-dimensional. They sag and flex in the complex wind environment, which is a different situation to ideal rigid cylinders in two-dimensional wind flow. Aerodynamic interference and the response characteristics of wake galloping of full-scale parallel cables are potentially different due to three-dimensional flows around cables. This study presents a comprehensive wind tunnel investigation of wake galloping of parallel stay cables using three-dimensional aeroelastic cable models. The wind tunnel study focuses on the large spacing instability range, addressing the effects of cable separation, wind yaw angle, and wind angle of attack on wake galloping response. To investigate the effectiveness of vibration suppression measures, wind tunnel studies on the transversely connected cable systems for two types of connections (flexibility and rigidity) at two positions (mid-span and quarter-span) were also conducted. This experimental study provides useful insights for better understanding the characteristics of wake galloping that will help in establishing a guideline for the wind-resistant design of the cable system on cable-stayed bridges.

Binary Metal Oxide ($IrO_2-RuO_2$) pH Sensor Prepared by Sol-gel Method (Sol-gel 법을 이용한 이성분 금속산화물 ($IrO_2-RuO_2$) pH 센서)

  • Lee, Jeong-Ran;Oh, Se-Lim;Han, Won-Sik;Hong, Tae-Kee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.190-196
    • /
    • 2014
  • The sol-gel method was used to prepare binary metal oxide ($IrO_2-RuO_2$) pH sensor. The electrodes that mole percent compositions (mol%) of $IrO_2$ and RuO2 were 70:30 and 30:70 were selected. The characterizations of Nernstian response over pH range, response rate, interference on alkaline metals and reproducibility were investigated. Also the electroanalytical properties of these electrodes were evaluated in comparison with a commercial glass pH electrode. The composition of $IrO_2:RuO_2$ 70:30 mol% was chosen as better electrode formulation. The electrode was not susceptible to the action of interfering ions such as $Li^+$, $Na^+$ and $K^+$.

Design and Fabrication of a Mass-spring System for the Force-balance Servo Accelerometer (힘평형 서보 가속도계의 질량지지 장치 설계 및 제작)

  • Kim, Young-Dam;Go, Young-Jun;Nam, Hyo-Duk;Lee, Doo-Hee;Chang, Ho-Gyeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.14-20
    • /
    • 2001
  • The mass-spring system with four arms for the force-balance servo accelerometer was designed and fabricated. The response characteristics of a mass-spring system was calculated with the change of arms thickness and seismic mass by the finite element method (FEM). Furthermore, the response characteristics of accelerometer was measured using the change of interference pattern and response voltage value by Michelson interferometer. The response characteristics with changing length and thickness of arm was changed drastically, and changing seismic mass was minor effect for the response characteristics of mass-spring system. The measured resonant frequencies have good agreement with that of numerical analysis within 5% range.

  • PDF

Functional Polymeric Materials for Biomedical Application (생체의료용 기능성 고분자 재료의 개발)

  • Sung, Yong-Kiel;Song, Dae-Kyung;Sung, Jung-Suk
    • Polymer(Korea)
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2006
  • The development of functional polymeric materials for biomedical application has progressed on the basis of functionality, biocompatibility and biodegradability. In this paper we review the functional polymeric biomaterialsbased systems and propose a range of biomedical applications in the near future. These systems include the functional biodegradable polymers synthesized in our research laboratory, biodegradable polymeric materials, thermosensitive polymeric materials, cationic polymeric materials, non-condensing polymeric biomaterials, bio-polymeric DNA matrix for tissue engineering, and polymeric biomaterials for RNA interference (RNAi) technology.

Dimming Control System Using Power Line Communication (전력선 통신을 이용한 조광 제어 시스템)

  • 박종연;주병훈
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.6
    • /
    • pp.632-637
    • /
    • 2000
  • In this paper, to control with light dimming levels of the fluorescent lamps, we have used the power line instead of the signal line to transmit the control signals. To reduce the BER(Bit Error Rate) on the power line communication with the serious noise interferences. We have adapted the FSK(Frequency Shift Keying) modulation and demodulation technique. Since the electronic ballast produced the EMI(ElctroMagnetic Interference) noise in some frequency bands, we have reduced the EMI levels in the band below -50dB. By varying the switching frequency of the ballast for the FL032/T8 from 18kHz to 25kHz, it is possible that the dimming levels are controled with the range of 5∼100%

  • PDF

Search for Gravity Waves with n New All-sky Camera System

  • Kim, Yong-Ha;Chung, Jong-Kyun;Won, Yong-In;Lee, Bang-Yong
    • Ocean and Polar Research
    • /
    • v.24 no.3
    • /
    • pp.263-266
    • /
    • 2002
  • Gravity waves have been searched for with a new all-sky camera system over Korean Peninsular. The all-sky camera consists of a 37mm/F4.5 Mamiya fisheye lens with a 180 dog field of view, interference filters and a 1024 by 1024 CCD camera. The all-sky camera has been tested near Daejeon city, and moved to Mt. Bohyun where the largest astronomical telescope is operated in Korea. A clear wave pattern was successfully detected in OH filter images over Mt. Bohyun on July 18, 2001, indicating that small scale coherent gravity waves perturbed OH airglow near the mesopause. Other wave features are since then observed with Na 589.8nm and OI 630.0nm filters. Since a Japanese all-sky camera network has already detected traveling ionospheric disturbances (TID) over the northeast-southwest range of Japanese islands, we hope our all-sky camera extends the coverage of the TID's observations to the west direction. We plan to operate our all-sky camera all year around to study seasonal variation of wave activities over the mid-latitude upper atmosphere.