• Title/Summary/Keyword: Interference Range

Search Result 644, Processing Time 0.025 seconds

Impact of the human body in wireless propagation of medical implants for tumor detection

  • Morocho-Cayamcela, Manuel Eugenio;Kim, Myung-Sik;Lim, Wansu
    • Journal of Internet Computing and Services
    • /
    • v.21 no.2
    • /
    • pp.19-26
    • /
    • 2020
  • This paper analyses the feasibility of using implantable antennas to detect and monitor tumors. We analyze this setting according to the wireless propagation loss and signal fading produced by human bodies and their environment in an indoor scenario. The study is based on the ITU-R propagation recommendations and prediction models for the planning of indoor radio communication systems and radio local area networks in the frequency range of 300 MHz to 100 GHz. We conduct primary estimations on 915 MHz and 2.4 GHz operating frequencies. The path loss presented in most short-range wireless implant devices does not take into account the human body as a channel itself, which causes additional losses to wireless designs. In this paper, we examine the propagation through the human body, including losses taken from bones, muscles, fat, and clothes, which results in a more accurate characterization and estimation of the channel. The results obtained from our simulation indicates a variation of the return loss of the spiral antenna when a tumor is located near the implant. This knowledge can be applied in medical detection, and monitoring of early tumors, by analyzing the electromagnetic field behavior of the implant. The tumor was modeled under CST Microwave Studio, using Wisconsin Diagnosis Breast Cancer Dataset. Features like the radius, texture, perimeter, area, and smoothness of the tumor are included along with their label data to determine whether the external shape has malignant or benign physiognomies. An explanation of the feasibility of the system deployment and technical recommendations to avoid interference is also described.

Analysis of Lead Ions in a Waste Solution Using Infrared Photo-Diode Electrode

  • Ly, Suw-Young;Lee, Hyun-Kuy;Kwak, Kyu-Ju;Ko, Jun-Seok;Lee, Jeong-Jae;Cho, Jin-Hee;Kim, Ki-Hong;Kim, Min-Seok;Lee, So-Jung
    • Toxicological Research
    • /
    • v.24 no.3
    • /
    • pp.227-233
    • /
    • 2008
  • To detect lead ions using electrochemical voltammetric analysis, Infrared Photo-Diode Electrode(IPDE) was applied via cyclic and square wave stripping voltammetry. Lead ions were deposited at 0.5 V(versus Ag/AgCl) accumulation potential. Instrumental measurements systems were made based on a simple and compact detection system. The stripping voltammetric and cyclic voltammetric optimal parameters were searched. The results yielded a cyclic range of $40{\sim}240mgl^{-1}$ Pb(II) and a square wave stripping working range of $0.5{\sim}5.00mgl^{-1}$ Pb(II). The relative standard deviation at 2 and 4 $mgl^{-1}$ Pb(II) was 0.04% and 0.02%(n=15), respectively, using the stripping voltammetric conditions. The detection limit was found to be 0.05 $mgl^{-1}$ with a 40 sec preconcentration time. Analytical interference ions were also evaluated. The proposed method was applied to determine lead ions in various samples.

A Study on the Next Generation Dedicated Short Range Communication System using OFDM (OFDM 방식의 차세대 단거리전용 통신 시스템 성능 개선에 관한 연구)

  • Kim, Man-Ho;Kang, Heau-Jo
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.4
    • /
    • pp.394-399
    • /
    • 2006
  • In this paper, we investigated performance for 5.8GHz dedicated short range communication system using OFDM which will be applied to Intelligent transportation system services. The maximum speed of a vehicle in DSRC channel is very fast as 180km/h, so a service time is very short to serve a various traffic information if hand-off is not occurred. Therefore higher bit rate is required to proved advanced and intelligent service to the drivers of various vehicle and the data transmission rate of the next generation DSRC system if being promoted over 10Mbps. The signals received in Clarke & Gans channel have been simulated using the computer simulator.

  • PDF

Development of Fiber Optic Accelerometer for Third-Party Damage Detection (타공사 감시를 위한 광섬유 가속도계의 개발)

  • Park, Ho-Rim;Choe, Jae-Bung;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1551-1558
    • /
    • 2001
  • Recently, a number of underground pipelines have been drastically increased. The integrity of these buried pipelines, especially gas transmitting pipelines, is of importance due to an explosive characteristic of natural gas. The third party damage is known as one of the most critical factor which causes fatal accidents. For this reason, a number of systems detecting third party damage are under development. The major concern in the development of third party damage detection system is to transmit vibration signals out of accelerometer to signal conditioner and data acquisition system without any interference caused by noise. The objective of this paper is to develope a fiber optic accelerometer applicable to third party damage detection system. A fiber optic accelerometer was developed by use of combining principles of one degree of freedom vibration model and an extrinsic Fabry-Perot interferometer. The developed fiber optic accelerometer was designed to perform with a sensitivity of 0.06mVg, a frequency range of less than 6kHz and an amplitude range of -200g to 200g. The developed, accelerometer was compared with a piezoelectric accelerometer and calibrated. In order to verify the developed accelerometer, the field experiment was performed. From the field experiment, vibration signals and the location of impact were successfully detected. The developed accelerometer is expected to be used for the third party damage detection system which requires long distance transmission of signals.

Spectrophotometric Determination of Iron with 2-Hydroxybenzaldehyde-5-nitro-pyridylhydrazone after Separation with Amberlite XAD-7 Nonionic Resin (Amberlite XAD-7 비이온성 수지로 분리 후 2-Hydroxybenzaldehyde-5-nitro-pyridylhydrazone을 이용한 철의 분광학적 정량)

  • Park, Chan Il;Chung, Byung Doo;Jung, Duck Chae;Cha, Ki Won
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.5
    • /
    • pp.522-526
    • /
    • 1999
  • 2-Hydroxybenzaldehyde-5-nitro-pyridylhydrazone (2HB-5NPH) was synthesized and its application to the spectrophotometric determination of iron was studied. The reagent reacts with iron in the pH range 6.0-7.5 to form a yellow coIored 1:2 chelate which is very stable in methanol solution. Beer's law is obeyed in the concentration range 0.05∼2.0 ${\mu}gmL^{-1}$ iron and separation procedure using a short column filled with Amberlite XAD-7 nonionic chelating resin is proposed for the spectrophotometric determination of traces of iron. The influence of several ions as interference was discussed. The separation of Fe(III) ion from the mix-ture solution were carried out with the buffer solution (pH 5.0) and 0.25M HCl as eluents.

  • PDF

An Algorithm for Estimating Ep/No of UWB Signals (UWB 신호의 Ep/No 추정 알고리즘)

  • Im, Sung-Bin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9C
    • /
    • pp.1316-1322
    • /
    • 2004
  • Recently, the UWB (ultra wide-band) wireless communication technology, which provides high data transmission and is capable of linearly trading between throughput and signal-to-noise ratio (SNR), has drawn much attention for short-range wireless networks. Fully exploiting its notable features and minimizing its interference to coexisting other systems require the knowledge of SNR's at receivers In this paper, we propose an algorithm for estimating the pulse energy to noise ratio Ep/No of UWB signal with utilization of outputs from a correlator at a receiver, and evaluate the performance of the proposed algorithm through computer simulation. According to simulation results, the maximum standard deviation is about 1 13 dB with a block size of 500. Except for Ep/No=O and 2 dB cases with a block size of 500, no errors greater than 3 dB were observed in all the remaining experiments. Generally speaking, it improves as the true Ep/No, increases and as the block size increases A notable feature of the proposed algorithm is that it does not reduce the effective throughput because the estimation process does not require sending additional training signal of any specific format.

Organopalladium(II) Complexes as Ionophores for Thiocyanate Ion-Selective Electrodes

  • Kim, Dong-Wan;Lee, So-Hyun;Kim, Jung-Hwan;Kim, Jin-Eun;Park, Jong-Keun;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2303-2308
    • /
    • 2009
  • A thiocyanate poly(vinyl chloride) (PVC) membrane electrode based on [1,2-bis(diphenylphosphino)ethane]dihalopalladium( II), [(dppe)$PdX_2$, X = Cl ($L^1$), X = I ($L^2$)] as active sensor has been developed. The diiodopalladium complex, [(dppe)$PdI_2](L^2$) displays an anti-Hofmeister selectivity sequence: $SCN^-\;>\;I^-\;>\;{ClO_4}^-\;>\;Sal^-\;>\;Br^-\;>\;{NO_2}^-\;>\;{HPO_4}^-\;>\;AcO^-\;>\;{NO_3}^-\;>\;{H_2PO_4}^-\;>\;{CO_3}^{2-}$. The electrode exhibits a Nernstian response (-59.8 mV/decade) over a wide linear concentration range of thiocyanate ($(1.0\;{\times}\;10^{-1}\;to\;5.0\;{\times}\;10^{-6}$ M), low detection limit ($(1.1\;{\times}\;10^{-6}$ M), fast response $(t_{90%}$ = 24 s), and applicability over a wide pH range (3.5∼11). Addition of anionic sites, potassium tetrakis[p-chlorophenyl] borate (KTpClPB) is shown to improve potentiometric anion selectivity, suggesting that the palladium complex may operate as a partially charged carrier-type ionophore within the polymer membrane phase. The reaction mechanism is discussed with respect to UV-Vis and IR spectroscopy. Application of the electrode to the potentiometric titration of thiocyanate ion with silver nitrate is reported.

GHz EMI Characteristics of 3D Stacked Chip PDN with Through Silicon Via (TSV) Connections

  • Pak, Jun-So;Cho, Jong-Hyun;Kim, Joo-Hee;Kim, Ki-Young;Kim, Hee-Gon;Lee, Jun-Ho;Lee, Hyung-Dong;Park, Kun-Woo;Kim, Joung-Ho
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.4
    • /
    • pp.282-289
    • /
    • 2011
  • GHz electromagnetic interference (EMI) characteristics are analyzed for a 3dimensional (3D) stacked chip power distribution network (PDN) with through silicon via (TSV) connections. The EMI problem is mostly raised by P/G (power/ground) noise due to high switching current magnitudes and high PDN impedances. The 3D stacked chip PDN is decomposed into P/G TSVs and vertically stacked capacitive chip PDNs. The TSV inductances combine with the chip PDN capacitances produce resonances and increase the PDN impedance level in the GHz frequency range. These effects depend on stacking configurations and P/G TSV designs and are analyzed using the P/G TSV model and chip PDN model. When a small size chip PDN and a large size chip PDN are stacked, the small one's impedance is more seriously affected by TSV effects and shows higher levels. As a P/G TSV location is moved to a corner of the chip PDNs, larger PDN impedances appear. When P/G TSV numbers are enlarged, the TSV effects push the resonances to a higher frequency range. As a small size chip PDN is located closer to the center of a large size chip PDN, the TSV effects are enhanced.

Analysis on the RFI Noise Path of Electrical Railway System in the Frequency Range of 9 kHz to 150 kHz (전기철도 시스템의 9~150 kHz 대역에서의 RFI 노이즈 전달 경로 분석)

  • Kwun, Suk-Tai;Chung, Yeon-Choon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.12
    • /
    • pp.1373-1379
    • /
    • 2012
  • The interaction of magnetic field in the frequency range of 9~150 kHz radiating from a railway system with wireless systems has been the cause of radio frequency interference. In this paper, the equivalent circuit model of the RFI noise is proposed through source and transfer path analysis, and it is confirmed that the switching noise of several kHz that occurs a vehicle traction drive system and a substation is radiated by forming the loop circuit with a feeder line by a rolling stock. And the validity of the proposed equivalent circuit model is verified by analyzing the effects of RC banks installed in the real railway between Guri and Guksu stations, the RFI noise can be effectively mitigated by loading suitable capacitance between rail and feeding line.

Development of EM Wave Absorber for Millimeter Wave Radar (밀리미터 레이더용 전파흡수체 개발)

  • Choi Chang-Mook;Kim Dong-Il;Je Seung-Hun;Choi Yun-Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.223-227
    • /
    • 2006
  • The millimeter-wave radar is positioned as a key, basic ITS technology supporting safe driving, because millimeter wave allows radar to see small distant objects. This system is considered the collision-avoidance radar available in some cars. This system employs poised radar operating within the frequency range $76\sim77GHz$. Radar systems create two major problems(false images and system-to-system interference). False echoes cause driving hazards. These problems can be eliminated through the use of EM wave absorber. Therefore, we designed and fabricated EM wave absorber using permalloy. It has the thickness of 1.4 mm with composition of permalloy:CPE=70:30 wt% and absorption ability higher than 18 dB in the frequency range $76\sim77GHz$.

  • PDF