• 제목/요약/키워드: Interface structure

검색결과 2,431건 처리시간 0.03초

Deposition of Plasma Polymerized Films on Silicon Substrates Using Plasma Assisted CVD Method For Low Dielectric Application

  • Kim, M.C.;S.H. Cho;J.H. Boo;Lee, S.B.;J.G. Han;B.Y. Hong;S.H. Yang
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2001년도 춘계학술발표회 초록집
    • /
    • pp.72-72
    • /
    • 2001
  • Plasma polymerized thin films have been deposited on Si(lOO) substrates at $25-400^{\circ}C$ using thiophene ($C_4H_4S$) precursor by plasma assisted chemical vapor deposition (PACVD) method for low-dielectric device application. In order to compare physical properties of the as-grown thin films, the effects of the plasma power, gas flow ratio and deposition temperature on the dielectric constant and thermal stability were mainly studied. XRD and TED studies revealed that the as-grown thin films have highly oriented amorphous polymer structure. XPS data showed that the polymerized thin films that grown under different RF power and deposition temperature as well as different gas ratio of $Ar:H_2$ have different stoichiometric ratio of C and S compared with that of monomer, indicating a formation of mixture polymers. Moreover, we also realized that oxygen free and thermally stable polymer thin films could be grown at even $400^{\circ}C$. The results of SEM, AFM and TEM showed that the polymer films with smooth surface and sharp interface could be grown under various deposition conditions. From the electrical property measurements such as I-V and C-V characteristics, the minimum dielectric constant and the best leakage current were obtained to be about 3.22 and $10-11{\;}A/\textrm{cm}^2$, respectively.

  • PDF

수중안전을 위한 인체 위치추적 모니터링 장치 구현 (Implementation of Human Positioning Monitoring Device for Underwater Safety)

  • 윤종화;윤달환
    • 전기전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.225-233
    • /
    • 2023
  • 본 논문은 해양사고 시 인체 인양정보를 모니터링하는 시스템을 구현한다. 모니터링 시스템은 수중환경 정보를 송신하는 인양기구제어기를 통하여 초음파 통신을 수행하며, 수상에서는 관제센터 또는 모선까지 10 km내 GPS 정보를 제공하기 위해 LoRa 통신을 수행한다. 수중 인양제어기는 공압 센서, 자이로 센서 및 온도센서 정보를 전송한다. 수중조건은 수심 10m 마다 수압 1기압씩 높아지고, 기구의 공기양은 육상에 비해서 1/2씩 줄어드는 환경에서 60 kg 수중 마네킹을 모델을 사용한다. 인양기구 SMB(Surface Marker Buoy)에 38g의 CO2 카트리지 1개를 사용하여 10 sec 이내에 수면 상승 조건을 기반으로 인양기구 출수 시험을 한다. 수중 통신은 수심 40m에서 100m까지 2,400bps 초음파 센서를 이용하여 데이터 전송환경을 구성한다. 모니터링 신호는 수심, 수온, 방향각 등을 수면 위의 구조요원에게 제공함으로써 인양작업자의 안전과 안전한 인체 구조를 목표로 한다.

RTI기반 시뮬레이션의 상호운용성 향상을 위한 연동모델의 모듈화 방안에 대한 연구 (The Research of the Modularity of Federation Object Model to Improve Interoperability of RTI-based Simulations)

  • 심준용;조원섭;진정훈;김세환
    • 한국시뮬레이션학회논문지
    • /
    • 제18권3호
    • /
    • pp.139-146
    • /
    • 2009
  • 최근 국방관련 소프트웨어 산업은 자원 및 비용의 한계를 극복하기 위해서 M&S(Modeling & Simulation) 기반의 분산 시뮬레이션 시스템 개발을 늘리고 있다. 이러한 시스템을 개발하는데 있어 모의되는 개체의 재사용성과 개체 간 상호운용성의 제공은 핵심기술 중 하나이다. HLA 인터페이스 표준 구현물인 RTI는 이러한 핵심기술을 제공할 수 있는 소프트웨어로써, 시뮬레이션에 참여하는 모의기 간 정보교환을 위해서 시뮬레이션 연동모델인 FOM(Federation Object Model)을 사용하며, 각각의 모의기는 참여하는 시뮬레이션 내에서 동일한 FOM을 소유해야만 하는 특징을 지닌다. 본 논문에서는 기 개발된 HLA/RTI 기반의 시뮬레이션 네트워크 관리자에 적용된 연동모델의 재사용성과 상호운용성을 향상시키기 위해서 SISO 표준인 BOM(Base Object Model) 모델의 특징을 살펴보고, FOM 모델의 모듈화를 통해서 시뮬레이션 네트워크 관리자의 구조설계 방안을 제시한다.

웹쉘 기술을 통한 프록시 기반의 확장 가능한 서버 관리 프레임워크 (Proxy-Based Scalable Server Access Management Framework Using Reverse Webshell Protocol)

  • 김다은;배상욱;김성민;정은영
    • 정보보호학회논문지
    • /
    • 제33권4호
    • /
    • pp.661-670
    • /
    • 2023
  • 서버리스 컴퓨팅 패러다임의 등장과 함께 클라우드 기술이 발전함에 따라, 서버 관리를 위한 백엔드 인프라의 구조가 온프레미스부터 최신 컨테이너 기반 서버리스 컴퓨팅까지 다변화되고 있다. 그럼에도 불구하고, 서버 관리를 위한 접속방식은 전통적인 SSH 프로토콜에 여전히 의존하고 있으며, 보안성 및 확장성 측면에서의 한계점으로 인해, 사용자의 서버 인프라 관리 편의성 및 업무 생산성을 저하시킨다. 이러한 문제를 해결하기 위해 본 논문에서는 웹쉘을 프록시 기반의 서버 관리 프레임워크에 적용하여 실용성과 보안성을 갖춘 서버 관리체계 설계에 활용하고자 한다. 흔히 해커들이 서버의 취약점을 이용하여 임의 명령을 실행하기 위해 웹쉘을 사용하지만, 본 논문에서는 서버 관리 측면에서의 웹쉘 기술의 활용성에 대해 고찰하고, 웹쉘 기술을 사용한 접속 프록시 기반 서버 관리 프레임워크를 새롭게 제안한다. 또한, 본 논문에서는 실제 구현을 통하여 제안한 프레임워크가 추가적인 오버헤드 없이 표준적인 서버 접속 프로토콜로 사용되어온 SSH의 단점을 보완하고, 현대의 다양화된 컴퓨팅 환경에서도 대규모의 인프라를 효율적으로 운영할 수 있음을 보인다.

A Study on the Magnetic Properties of Ion Irradiated Cu/Co Multilayer System

  • Kim, T.Y.;Chang, G.S.;Son, J.H.;Kim, S.H.;Shin, S.W.;Chae, K.H.;Sung, M.C.;Lee, J.;Jeong, K.;Lee, Y.P.;;Whang, C.N
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.163-163
    • /
    • 2000
  • In this research, we used the ion irradiation technique which has an advantae in improving intentionally the properties of surface and interface in a non-equilibrium, instead of the conventional annealing method which has been known to improve the material properties in the equilibrium stat. Cu/Co multilayered films were prepared on SiN4/SiO2/Si substrates by the electron-beam evaporation for the Co layers and the thermal evaporation for the Cu layers in a high vacuum. The ion irradiation with a 80keV Ar+ was carried out at various ion doses in a high vacuum. Hysteresis loops of the films were investigated by magneto-optical polar Kerr spectroscopy at various experimental conditions. The change of atomic structure of the films before and after the ion irradiation was studied by glancing angle x-ray diffraction, and the intermixing between Co and Cu sublayers was confirmed by Rutherford backscattering spectroscopy. The surface roughness and magneto-resistance were measured by atomic force microscopy and with a four-point probe system, respectively. During the magneto-resistance measurement, we changed temperature and the direction of magnetization. From the results of experiments, we found that the change at the interfaces of the Cu/Co multilayered film induced by ion irradiation cause the change of magnetic properties. According to the change in hysteresis loop, the surface inplane component of magnetic easy axis was isotropic before the ion irradiation, but became anisotropic upon irradiation. It was confirmed that this change influences the axial behavior of magneto-resistance. Especially, the magneto-resistance varied in accordance with an external magnetic field and the direction of current, which means that magneto-resistance also shows the uniaxial behavior.

  • PDF

베지어 곡선을 활용한 육각 그리드의 그림자 생성 방법 (Hexagonal Grid Shadow Generation using Bézier Curves)

  • 김민석;남택관;박영진
    • 스마트미디어저널
    • /
    • 제12권4호
    • /
    • pp.47-57
    • /
    • 2023
  • 육각 그리드(hexagonal grid) 구조는 지리정보시스템에서 공간정보 데이터를 처리하고 표현하기에 우수하여 많은 연구가 이루어지고 있다. 육각 그리드를 이용한 시각화는 다른 그리드 표현 방법 대비 시인성이 높지만, 이에 표현된 공간정보 데이터에 따라 양적 정보와 그리드 간 데이터 차이를 효과적으로 전달하는 데 어려움이 있다. 따라서, 본 연구에서는 육각 그리드 외곽에 그림자를 생성하여 시각적으로 육각 그리드를 강조하는 방법을 제안한다. 이를 위해 강조하고자 하는 육각 그리드들의 최외곽 선분들을 오프셋 시키고, 그 정보를 바탕으로 베지어 곡선을 생성하여 최종적인 그림자 형상을 결정한다. 그림자는 육각 그리드에서 멀어질수록 서서히 옅어진다는 특성을 활용하여, 그림자의 가장자리로 갈수록 투명도를 가변적으로 적용한다. 제안하는 방법을 이용하여 하나의 육각 그리드뿐만 아니라 여러 개의 육각 그리드가 주어지더라도 그림자 영역을 효과적으로 생성할 수 있음을 보였으며, 사용자 인터페이스의 입력에 따라 다양한 그림자 형상을 생성할 수 있다. 서울특별시의 행정구 중 용산구에 제안하는 방법을 활용하여 그림자를 생성한 후 시각적으로 강조한 결과를 보인다.

Effect of Carbon Fiber Layer on Electrochemical Properties of Activated Carbon Electrode

  • Jong kyu Back;Jihyeon Ryu;Yong-Ho Park;Ick-Jun Kim;Sunhye Yang
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권2호
    • /
    • pp.184-193
    • /
    • 2023
  • This study investigates the effects of a carbon fiber layer formed on the surface of an etched aluminum current collector on the electrochemical properties of the activated carbon electrodes for an electric double layer capacitor. A particle size analyzer, field-emission SEM, and nitrogen adsorption/desorption isotherm analyzer are employed to analyze the structure of the carbon fiber layer. The electric and electrochemical properties of the activated carbon electrodes using a carbon fiber layer are evaluated using an electrode resistance meter and a charge-discharge tester, respectively. To uniformly coat the surface with carbon fiber, we applied a planetary mill process, adjusted the particle size, and prepared the carbon paste by dispersing in a binder. Subsequently, the carbon paste was coated on the surface of the etched aluminum current collector to form the carbon under layer, after which an activated carbon slurry was coated to form the electrodes. Based on the results, the interface resistance of the EDLC cell made of the current collector with the carbon fiber layer was reduced compared to the cell using the pristine current collector. The interfacial resistance decreased from 0.0143 Ω·cm2 to a maximum of 0.0077 Ω·cm2. And degradation reactions of the activated carbon electrodes are suppressed in the 3.3 V floating test. We infer that it is because the improved electric network of the carbon fiber layer coated on the current collector surface enhanced the electron collection and interfacial diffusion while protecting the surface of the cathode etched aluminum; thereby suppressing the formation of Al-F compounds.

A Comparative Study Between High and Low Infiltration Soils as Filter Media in Low Impact Development Structures

  • Guerra, Heidi B.;Geronimo, Franz Kevin;Reyes, Nash Jett;Jeon, Minsu;Choi, Hyeseon;Kim, Youngchul;Kim, Lee-Hyung
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.130-130
    • /
    • 2021
  • The increasing effect of urbanization has been more apparent through flooding and downstream water quality especially from heavy rainfalls. In response, stormwater runoff management solutions have focused on runoff volume reduction and treatment through infiltration. However, there are areas with low infiltration soils or are experiencing more dry days and even drought. In this study, a lab-scale infiltration system was used to compare the applicability of two types of soil as base layer in gravel-filled infiltration systems with emphasis on runoff capture and suspended solids removal. The two types of soils used were sandy soil representing a high infiltration system and clayey soil representing a low infiltration system. Findings showed that infiltration rates increased with the water depth above the gravel-soil interface indicating that the available depth for water storage affects this parameter. Runoff capture in the high infiltration system is more affected by rainfall depth and inflow rates as compared to that in the low infiltration system. Based on runoff capture and pollutant removal analysis, a media depth of at least 0.4 m for high infiltration systems and 1 m for low infiltration systems is required to capture and treat a 10-mm rainfall in Korea. A maximum infiltration rate of 200 mm/h was also found to be ideal to provide enough retention time for pollutant removal. Moreover, it was revealed that low infiltration systems are more susceptible to horizontal flows and that the length of the structure may be more critical that the depth in this condition.

  • PDF

Validation of model-based adaptive control method for real-time hybrid simulation

  • Xizhan Ning;Wei Huang;Guoshan Xu;Zhen Wang;Lichang Zheng
    • Smart Structures and Systems
    • /
    • 제31권3호
    • /
    • pp.259-273
    • /
    • 2023
  • Real-time hybrid simulation (RTHS) is an effective experimental technique for structural dynamic assessment. However, time delay causes displacement de-synchronization at the interface between the numerical and physical substructures, negatively affecting the accuracy and stability of RTHS. To this end, the authors have proposed a model-based adaptive control strategy with a Kalman filter (MAC-KF). In the proposed method, the time delay is mainly mitigated by a parameterized feedforward controller, which is designed using the discrete inverse model of the control plant and adjusted using the KF based on the displacement command and measurement. A feedback controller is employed to improve the robustness of the controller. The objective of this study is to further validate the power of dealing with a nonlinear control plant and to investigate the potential challenges of the proposed method through actual experiments. In particular, the effect of the order of the feedforward controller on tracking performance was numerically investigated using a nonlinear control plant; a series of actual RTHS of a frame structure equipped with a magnetorheological damper was performed using the proposed method. The findings reveal significant improvement in tracking accuracy, demonstrating that the proposed method effectively suppresses the time delay in RTHS. In addition, the parameters of the control plant are timely updated, indicating that it is feasible to estimate the control plant parameter by KF. The order of the feedforward controller has a limited effect on the control performance of the MAC-KF method, and the feedback controller is beneficial to promote the accuracy of RTHS.

철근 부식과 축방향 하중을 받는 철근-콘크리트 기둥 단면의 손상 평가 (Evaluation of Cross-Sectional Damage for RC Column Subjected to Axial Loading and Steel Corrosion)

  • 김창영;안기용
    • 한국건설순환자원학회논문집
    • /
    • 제11권4호
    • /
    • pp.476-483
    • /
    • 2023
  • 본 연구에서는 철근-콘크리트 기둥의 3차원 유한요소 모델링을 통해 콘크리트 기둥 단면의 균열에 대한 철근의 부식과 하중의 영향을 해석적으로 분석했다. 철근 부식에 대한 콘크리트 계면 공극의 완충 효과를 반영했으며, 철근의 부식과정은 표면 하중을 통해 그 직경을 점진적으로 확장시킴으로써 구현했다. 이러한 변수들을 통한 해석적 접근을 통해 단면균열에 대한 (1) 기하학적 조건으로 대변되는 단면에서의 위치와 (2) 경계조건으로 대변되는 축방향 하중과 철근 부식량의 영향성을 분석했다. 철근-콘크리트 계면 균열은 계면 공극을 압도적으로 넘어서는 양의 부식이 진행된 조건에서 압축변형에 의해 발생됐으며, 기둥 표면의 균열은 축하중에 의한 인장변형으로 발생되며, 표면에서 발생된 균열은 기둥 단면의 내부로 발달됐다. 인장변형에 의한 계면균열은 축하중에 의존적이었으며, 단면의 피복부 균열 보다 선행적으로 발생됐다. 또한 축하중은 압축변형에 의해 발생되는 계면 균열의 분포와 속도에 영향을 미쳤으며, 인장 변형에 의한 균열에 지배적인 영향을 미쳤다.