• Title/Summary/Keyword: Interface dose

Search Result 81, Processing Time 0.034 seconds

Radiation effects of I-V characteristics in MOS structure irradiated under $Co^{60}-{\gamma}$ ray ($Co^{60}-{\gamma}$ ray을 조사시킨 MOS 구조에서의 I-V특성의 방사선 조사 효과)

  • Kwon, S.S.;Jeong, S.H.;Lim, K.J.;Ryu, B.H.;Kim, B.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.123-127
    • /
    • 1992
  • When MOS devices is exposed to radiation, radiation effects of P-type MOS capacitor can cause modulation and/or degradation in devices characteristics and its operating life. The oxide layer is grown in $O_2$+T.C.E. and its thickness ranges from 40 to 80 nm. Irradiations on MOS capacitor were performed by Cobalt-60 gamma ray source and total dose ranges from $10^4$ to $10^8$ rads. The radiation effect on electrical conduction characteristics(I-V) in MOS capacitor was measured as a function of gate oxide thickness and total dose. From the experimental result, I-V characteristics is found to be influenced strongly by total dose in irradiated p-type MOS capacitors. The ohmic current is dependant on of total dose in irradiated P-type MOS capacitors. This results are explained using surface states at interface radiation-induced traps.

  • PDF

CURRENT RESEARCH ON ACCELERATOR-BASED BORON NEUTRON CAPTURE THERAPY IN KOREA

  • Kim, Jong-Kyung;Kim, Kyung-O
    • Nuclear Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.531-544
    • /
    • 2009
  • This paper is intended to provide key issues and current research outcomes on accelerator-based Boron Neutron Capture Therapy (BNCT). Accelerator-based neutron sources are efficient to provide epithermal neutron beams for BNCT; hence, much research, worldwide, has focused on the development of components crucial for its realization: neutron-producing targets and cooling equipment, beam-shaping assemblies, and treatment planning systems. Proton beams of 2.5 MeV incident on lithium target results in high yield of neutrons at relatively low energies. Cooling equipment based on submerged jet impingement and micro-channels provide for viable heat removal options. Insofar as beam-shaping assemblies are concerned, moderators containing fluorine or magnesium have the best performance in terms of neutron accumulation in the epithermal energy range during the slowing-down from the high energies. NCT_Plan and SERA systems, which are popular dose distribution analysis tools for BNCT, contain all the required features (i.e., image reconstruction, dose calculations, etc.). However, detailed studies of these systems remain to be done for accurate dose evaluation. Advanced research centered on accelerator-based BNCT is active in Korea as evidenced by the latest research at Hanyang University. There, a new target system and a beam-shaping assembly have been constructed. The performance of these components has been evaluated through comparisons of experimental measurements with simulations. In addition, a new patient-specific treatment planning system, BTPS, has been developed to calculate the deposited dose and radiation flux in human tissue. It is based on MCNPX, and it facilitates BNCT efficient planning based via a user-friendly Graphical User Interface (GUI).

The Dosimetric Data of 10 MV Linear Accelerator Photon Beam for Total Body Irradiation (전신 방사선조사를 위한 10MV 선형가속기의 선량측정)

  • Ahn Sung Ja;Kang Wee-Saing;Park Seung Jin;Nam Taek Keun;Chung Woong Ki;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.225-232
    • /
    • 1994
  • Purpose : This study was to obtain the basic dosimetric data using the 10 MV X-ray for the total body irradiation. Materials and Methods : A linear accelerator photon beam is planned to be used as a radiation source for total body irradiation (TBI) in Chonnam University Hospital. The planned distance from the target to the midplane of a patient is 360cm and the maximum geometric field size is 144cm x 144cm. Polystyrene phantom sized $30{\times}30{\times}30.2cm^3$ and consisted of several sheets with various thickness, and a parallel plate ionization chamber were used to measure surface dose and percent depth dose (PDD) at 345cm SSD, and dose profiles. To evaluate whether a beam modifier is necessary for TBI, dosimetry in build up region was made first with no modifier and next with an 1cm thick acryl plate 20cm far from the polystyrene phantom surface. For a fixed sourec-chamber distance, output factors were measured for various depth. Results : As any beam modifier was not on the way of radiation of 10MV X-ray, the $d_{max}$ and surface dose was 1.8cm and $61\%$, respectively, for 345cm SSD. When an 1cm thick acryl plate was put 20cm far from polystyrene phantom for the SSD, the $d_{max}$ and surface dose were 0.8cm and $94\%$, respectively. With acryl as a beam spoiler, the PDD at 10cm depth was $78.4\%$ and exit dose was a little higher than expected dose at interface of exit surface. For two-opposing fields for a 30cm phantom thick phantom, the surface dose and maximum dose relative to mid-depth dose in our experiments were $102.5\%$ and $106.3\%$, respectively. The off-axis distance of that point of $95\%$ of beam axis dose were 70cm on principal axis and 80cm on diagonal axis. Conclusion: 1. To increase surface dose for TBI by 10MV X-ray at 360cm SAD, 1cm thick acrylic spoiler was sufficient when distance from phantom surface to spoiler was 20cm. 2. At 345cm SSD, 10MV X-ray beam of full field produced a satisfiable dose uniformity for TBI within $7\%$ in the phantom of 30cm thickness by two-opposing irradiation technique. 3. The uniform dose distribution region was 67cm on principal axis of the beam and 80cm on diagonal axis from beam axis. 4. The output factors at mid-point of various thickness revealed linear relation with depth, and it could be applicable to practical TBI.

  • PDF

Object-Oriented Stereotactic Radiosurgery Planning System (객체 지향 개념을 이용한 뇌정위 방사선 수술 계획 시스템)

  • Park, S.H.;Suh, T.S.;Suh, D.Y.;Kang, W.S.;Ha, S.H.;Kim, I.H.;Park, C.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.85-87
    • /
    • 1994
  • In this paper, we present an object-oriented stereotactic radiosurgery planning system, which accepts medical images such as CT and angiography, transforms the coordinates to a reference frame coordinate, calculates dose distributions, and finally displays isodose curves over the images. The user finds an adequate one for radiosurgeries after performing computer simulations on different treatment parameter sets. The object-oriented design concept was fully applied to the system composed of seven manager objects of different classes: a patient information manager, a user-interface manager, a coordinate transformation manager, a blackboard manager, a dose calculation manager, an isodose curve display manager, and a report manager. All the user interactions are carried out through the use of mouse buttons. The performance of the system was verified by four physicians and two medical physicists, and now is being used in two clinical sites.

  • PDF

Development of Computer-based 2-D Radiation Therapy Planning System (컴퓨터를 이용한 통합적 2차원 방사선치료계획장치 개발)

  • Suh, T.S.;Yoon, S.C.;Suh, D.Y.;Kim, M.C.;Lee, H.K.;Choe, B.Y.;Shinn, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.64-65
    • /
    • 1998
  • The aim of this work is to develop computerized 2-D radiation therapy planning system. The algorithms to compute dose for photon, electron, radioisotope have been developed, and dose distributions were superimposed on CT or MR images. Using object oriented modeling the structure of program has been designed for the efficient user-interface. Finally, a prototyp of 2-D radiation therapy planning system has been successfully applied in clinical cases for the demonstration.

  • PDF

The Study on the Implementation and Design of Power Supply Unit of Digital Communication Satellite (디지털위성중계기용 전원공급기 설계 및 구현에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.9
    • /
    • pp.855-860
    • /
    • 2016
  • This study describes the design and implementation of digital Payload power supply. We materialized the interface of the PLDIU and power supply of a satellite bus, and minimized the potential for the occurrence of such erroneous operation circuit ESD through the WCA of the space environment. We designed a reliable power supply through simulation for a TID according to the vibration generated during the launch and space radiation environment, and found no problem in the function and performance through the test space environment after production.

Construction of the TLD Readout System Using the Personal Computer and Its Characteristics (PC를 이용한 TLD 판독장치의 제작과 특성조사)

  • U, Hong;Kang, Hee-Dong;Kim, Do-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.342-349
    • /
    • 1998
  • A multipurpose TLD readout system for radiation dosimetry and thermoluminescence study is constructed and its characteristics are investigated. The thermoluminescent lights are measured by a PM tube and the current-to-frequency converter. TLDs are heated by platinum heater and the heating rate is linearly varied. Measurement of the glow curve and control of the whole system have been done by a personal computer equipped with an interface board. The automatic gain control can be done by the control software. The lower detection limit of the system is about $10\;{\mu}Gy$ and dose response is linear.

  • PDF

Adhesion Properties of UV-curable Pressure Sensitive Adhesives for Dicing Tape (다이싱 테이프용 자외선 경화형 점착제의 접착 물성)

  • Do, Hyun-Sung;Kim, Sung-Eun;Kim, Hyun-Joong
    • Journal of Adhesion and Interface
    • /
    • v.5 no.4
    • /
    • pp.1-8
    • /
    • 2004
  • UV-curable pressure sensitive adhesives were prepared by blending acrylic copolymer, copolymerized with butyl acrylate, acrylic acid and methyl methacrylate by solution polymerization, and trimethylolpropane triacrylate. The PSAs were evaluated by adhesion strength with varying UV dose, and also glass transition temperature ($T_g$) of PSAs were measured. When exposed on UV irradiation, the PSAs showed the decreased adhesion strength and increased $T_g$. And following UV irradiation, the PSAs did not leave any residue on wafer after peel off PSA.

  • PDF

The Study on the Implementation and Design of Power Supply Unit of Digital of Dehop/Rehop Transponder of EQM (우주 인증용 대전자전중계기의 전원공급기 설계 및 구현에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.3
    • /
    • pp.437-442
    • /
    • 2021
  • This study describes the design and implementation of power supply of dehop/rehop transponder of EQM(Engineering Qualification Model). We materialized the interface of the PLDIU and power supply of a satellite bus, and minimized the potential for the occurrence of such erroneous operation circuit ESD through the WCA of the space environment. We designed a reliable power supply through simulation for TID about space radiation and simulation of the vibration generated during it launched, and we confirmed that it satisfies the environmental test specification through the test space environment after production.

Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer (두경부암 방사선치료 시 선량 균일도 향상을 위한 Thermoplastic 구강 보상체의 개발)

  • Choi, Joon-Yong;Won, Young-Jin;Park, Ji-Yeon;Kim, Jong-Won;Moon, Bong-Ki;Yoon, Hyong-Geun;Moon, Soo-Ho;Jeon, Jong-Byeong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.269-278
    • /
    • 2012
  • Aquaplast Thermoplastic (AT) is a tissue-equivalent oral compensator that has been developed to improve dose uniformity at the common boundary and around the treated area during radiotherapy in patients with head and neck cancer. In order to assess the usefulness of AT, the degree of improvement in dose distribution and physical properties were compared to those of oral compensators made using paraffin, alginate, and putty, which are materials conventionally used in dental imprinting. To assess the physical properties, strength evaluations (compression and drop evaluations) and natural deformation evaluations (volume change over time) were performed; a Gafchromic EBT2 film and a glass dosimeter inserted into a developed phantom for dose verification were used to measure the common boundary dose and the beam profile to assess the dose delivery. When the natural deformation of the oral compensators was assessed over a two-month period, alginate exhibited a maximum of 80% change in volume from moisture evaporation, while the remaining tissue-equivalent properties, including those of AT, showed a change in volume that was less than 3%. In a free-fall test at a height of 1.5 m (repeated 5 times as a strength evaluation), paraffin was easily damaged by the impact, but AT exhibited no damage from the fall. In compressive strength testing, AT was not destroyed even at 8 times the force needed for paraffin. In dose verification using a glass dosimeter, the results showed that in a single test, the tissue-equivalent (about 80 Hounsfield Units [HU]) AT delivered about 4.9% lower surface dose in terms of delivery of an output coefficient (monitor unit), which was 4% lower than putty and exhibited a value of about 1,000 HU or higher during a dose delivery of the same formulation. In addition, when the incident direction of the beam was used as a reference, the uniformity of the dose, as assessed from the beam profile at the boundary after passing through the oral compensators, was 11.41, 3.98, and 4.30 for air, AT, and putty, respectively. The AT oral compensator had a higher strength and lower probability of material transformation than the oral compensators conventionally used as a tissue-equivalent material, and a uniform dose distribution was successfully formed at the boundary and surrounding area including the mouth. It was also possible to deliver a uniformly formulated dose and reduce the skin dose delivery.