• 제목/요약/키워드: Interface dose

검색결과 81건 처리시간 0.03초

릴레이 궤환을 이용한 자동동조 PID 제어기의 GUI-Program 개발과 수위온도제어 플랜트에의 실시간 적용 (Development of GUI-program for Auto-tuning PID controller using relay feedback and Application of level-temperature plant)

  • 유병철;한진욱;이창구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.609-611
    • /
    • 1999
  • The purpose of this research is on figuring out the optimal PID parameter using critical gain and critical frequency that are obtained by relay feedback. The operating has been done under the condition that the least information about the object plant is given and also the operating is processed within the limit which dose not give rise to bad influence on the object plant. For simulation auto-tuning PID controller using relay feedback which also works on on-line at the same time is developed by the upper procedure. This algorithm is tried to apply to level-temperature control plant on a real time with PC Interface Card.

  • PDF

요마크 분석을 통한 사고 재구성 (Accident reconstruction using yaw mark analysis)

  • 하정섭;이승종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.443-446
    • /
    • 2002
  • A vehicle oversteered or cornering at excessive speed leaves tire yaw mark on the road surface. A yaw mark is a sign that the tire was sideslipping and exceeded its frictional limit because of centrifugal force. Problems exist with the traditional equation, “critical speed formula (CSF)”, that limits its practical use in traffic accident reconstruction. A major problem is that the equation dose not account for vehicle dynamics and interface between tire and road. The literature refers to that the accuracy of the critical speed formula varies with several factors. New equations that account for vehicle dynamics are introduced in this paper. A comparison of the accuracy of the new method and the traditional method in the calculation of speed is conducted.

  • PDF

Interface Characteristics of Ion Beam Mixed Cu/polyimide system

  • G.S.Chang;Jung, S.M.;Lee, Y.S.;Park, I.S.;Kang, H.J.;J.J.Woo;C.N.Whang
    • 한국진공학회지
    • /
    • 제4권S2호
    • /
    • pp.1-7
    • /
    • 1995
  • Cu(400$\AA$)/Polyimide has been mixed with 80 keV Ar+ and N2+from 1.0X1015ions/$\textrm{cm}^2$ to 2.0X1016 ions/$\textrm{cm}^2$. The changes of chemical bond and internal properties of sample are investigated by X-ray photoelectron spectroscopy(XPS). The quantitative adhesion strength is measured by using scratch test. The optimized mixing condition is that Cu/PI is irradiated with 80 keV N2+ at a dose of 1.0X1015 ions/$\textrm{cm}^2$, because N2+ ions can product more pyridine-like moiety, amide group, and tertiary amine moiety which are known as adesion promoters than Ar+.

  • PDF

호흡이 불규칙한 환자의 치료를 위한 Beam on/off Interface를 이용한 종양 추적 치료 방법의 성능 평가 (Performance Evaluation of the Tumor Tracking Method Using Beam on/off Interface for the Treatment of Irregular Breathing)

  • 이민식
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.343-349
    • /
    • 2018
  • 선량률을 조절하면서 종양을 추적하는 방법은 호흡이 불규칙한 환자를 치료할 때 방사선을 적응적으로 전달하는 효율적인 방법으로 알려져 있다. 이 연구에서는 빔 켜기/끄기 스위칭을 제공하는 모션 관리 인터페이스 (MMI, Varian Medical System, CA)를 이용한 불규칙 호흡에 대해 적응성 종양 추적을 시행 할 수 있는지 확인하였다. 폐암 환자로부터 획득한 55개의 호흡 정보를 사용하였다. 첫날 환자의 RPM 흔적을 사용하여 사전 프로그래밍 된 추적 MLC 패턴을 디자인하는데, 치료 기간 중 환자의 호흡 불규칙성의 변화를 따라 잡기 위해 기간을 의도적으로 20% 줄였다. 이 기술의 적정성 기준은 진폭 및 주기의 20 % 미만의 표준편차이다. 사전 프로그래밍 된 MLC 위치와 현재 호흡 위치를 고려하여 100 ms마다 빔 켜기 / 끄기를 결정하는 알고리즘이 개발되었다. 추적 오류 및 전달 효율성은 RPM 추적에서 빔 스위칭 적응형 추적을 시뮬레이션하여 계산되었다. 38 명의 환자(70%)의 호흡 양상이 적합 기준을 충족 시켰습니다. 기준을 충족하는 모든 사례의 추적 오류는 2 mm 미만 (평균 1.4 mm)이며 평균 전달 효능은 71 % 였다. 기준을 충족하지 못한, 나머지 경우의 추적오류와 전달 효율은 1.9 mm와 48% 였다. 본 연구를 통해, 환자 선택이 적격 기준을 기반으로 하는 경우 빔 스위칭을 통한 적응형 추적 치료가 가능한 것을 확인하였다.

Paclitaxel Coating Inhibits Inflammation Surrounding Subcutaneously Implanted Expanded Polytetrafluoroethylene (ePTFE) Hemodialysis Grafts in Rabbit Model

  • Baek, In-Su;Lee, Yu-Ji;Park, Soo-Jin;Bai, Cheng Zhe;Park, Jong-Sang;Kim, Dae-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권2호
    • /
    • pp.281-285
    • /
    • 2010
  • Hemodialysis vascular access dysfunction (HVAD) due to the aggressive development of venous neointimal hyperplasia remains a major complication for patients with synthetic arteriovenous grafts. Paclitaxel-coated expanded polytetrafluoroethylene (ePTFE) grafts effectively prevent neointimal hyperplasia and stenosis. However, perigraft inflammation or edema can be another complication of ePTFE grafts, preventing early cannulation. Three different types of ePTFE grafts, including grafts without paclitaxel coating (control group, n = 12), grafts with paclitaxel coating at a dose density of $0.61ug/mm^2$ (low concentration group, n = 12), and grafts with paclitaxel coating at a dose density of $1.15ug/mm^2$ (high concentration group, n = 12) were placed in the backs of 12 rabbits, simultaneously. Six rabbits were euthanized after one week and the remaining six were euthanized two weeks after implantation. Perigraft inflammation, graft wall inflammation, stromal cell proliferation, blood vessel formation, tissue necrosis and edema were analyzed for the grafts in each animal. Inflammation surrounding the paclitaxel-coated grafts was significantly reduced compared to the control group. Stromal cell layers were detected at the interface between the graft and the surrounding tissue in the control group, infiltrated into the graft interstices, and differentiated into myofibroblasts for graft healing. Paclitaxel-coated grafts inhibited stromal cell proliferation and infiltration into the graft wall. Tissue necrosis and edema were not detected in either of the paclitaxel-coated graft groups.

비접촉식 자외선 광반응조를 이용한 하수 대장균의 살균과 Log 불활성화율 지표 (Disinfection of E. coli from Wastewater using a Non-contact type UV Photoreactor and Log Inactivation Index)

  • 김성홍;김경면;김광일;최재완
    • 상하수도학회지
    • /
    • 제30권2호
    • /
    • pp.139-145
    • /
    • 2016
  • Disinfection of microorganisms using UV light is widely used in the field of water supply and wastewater treatment plant, In spite of high germicidal effect and relatively clean by-product, UV disinfection has fundamental defeat that is accumulation of fouling materials at the interface of water and lamp sleeve. Non-contact type of UV photoreactor which can avoid this fouling generation was developed and the experimental performance evaluation of the system was carried out in this study. Log inactivation rate of E. coli was selected as a disinfection index. The concentration of E. coli of second clarifier effluent was $8.2{\times}10^1-8.2{\times}10^3$ colony per mL and was well inactivated by the non-contact type of UV photoreactor. Under the UV intensity condition of $2.1-2.5mW/cm^2$, E. coli removal rate was observed in the range of 54 - 95% when the HRT was increased from 10 to 52 seconds. Experimental results showed that log inactivation of E. coli was proportional to UV dosage and $200mJ/cm^2$ of UV dose is expected for the 2.0 log inactivation of E. coli from the second clarifier effluent. Between the two parameters of UV intensity and contact time which are consist of UV dose, UV intensity was 4 times more effective than contact time.

Co/Ti 이중막 실리사이드 접촉을 갖는 p$^{+}$-n 극저접합의 형성 (Formation of p$^{+}$-n ultra shallow junction with Co/Ti bilayer silicide contact)

  • 장지근;엄우용;신철상;장호정
    • 전자공학회논문지D
    • /
    • 제35D권5호
    • /
    • pp.87-92
    • /
    • 1998
  • Ultr shallow p$^{+}$-n junction with Co/Ti bilayer silicidde contact was formed by ion implantation of BF$_{2}$ [energy : (30, 50)keV, dose:($5{\times}10^{14}$, $5{\times}10^{15}$/$\textrm{cm}^2$] onto the n-well Si(100) region and by RTA-silicidation and post annealing of the evaporated Co(120.angs., 170.angs.)/Ti(40~50.angs.) double layer. The sheet resistance of the silicided p$^{+}$ region of the p$^{+}$-n junction formed by BF2 implantation with energy of 30keV and dose of $5{\times}10^{15}$/$\textrm{cm}^2$ and Co/Ti thickness of $120{\AA}$/(40~$50{\AA}$) was about $8{\Omega}$/${\box}$. The junction depth including silicide thickness of about $500{\AA}$ was 0.14${\mu}$. The fabricated p$^{+}$ -n ultra shallow junction depth including silicide thickness of about $500{\AA}$ was 0.14${\mu}$. The fabricated p$^{+}$-n ultra shallow junction with Co/Ti bilayer silicide contact did not show any agglomeration or variation of sheet resistance value after post annealing at $850^{\circ}C$ for 30 minutes. The boron concentration at the epitaxial CoSi$_{2}$/Si interface of the fabricated junction was about 6*10$6{\times}10^{19}$ / $\textrm{cm}^2$./TEX>.

  • PDF

Development and Performance of a Hand-Held CZT Detector for In-Situ Measurements at the Emergency Response

  • Ji, Young-Yong;Chung, Kun Ho;Kim, Chang-Jong;Yoon, Jin;Lee, Wanno;Choi, Geun-Sik;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.87-91
    • /
    • 2016
  • Background: A hand-held detector for an emergency response was developed for nuclide identification and to estimate the information of the ambient dose rate in the scene of an accident as well as the radioactivity of the contaminants. Materials and Methods: To achieve this, the most suitable sensor was first selected as a cadmium zinc telluride (CZT) semiconductor and the signal processing unit from a sensor and the signal discrimination and storage unit were successfully manufactured on a printed circuit board. Results and Discussion: The performance of the developed signal processing unit was then evaluated to have an energy resolution of about 14 keV at 662 keV. The system control unit was also designed to operate the CZT detector, monitor the detector, battery, and interface status, and check and transmit the measured results of the ambient dose rate and radioactivity. In addition, a collimator, which can control the inner radius, and the airborne dust sampler, which consists of an air filter and charcoal filter, were developed and mounted to the developed CZT detector for the quick and efficient response of a nuclear accident. Conclusion: The hand-held CZT detector was developed to make the in-situ gamma-ray spectrometry and its performance was checked to have a good energy resolution. In addition, the collimator and the airborne dust sampler were developed and mounted to the developed CZT detector for a quick and efficient response to a nuclear accident.

The improvement of Cu metal film adhesion on polymer substrate by the low-power High-frequency ion thruster

  • Jung Cho;Elena Kralkina;Yoon, Ki-Hyun;Koh, Seok-Keun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.60-60
    • /
    • 2000
  • The adhesion interface formation between copper and poly(ethylene terephthalate)(PET), poly(methyl methacrylate)(PMMA) and Polyimide films was treated using Ion assisted reaction system to sequential sputter deposition by High-Frequency ion source. The ion beam modification system used a new type of low power HF ion thruster for space application as new low thruster electric propulsion system. Low power HF ion thruster with diameter 100mm gives the opportunity to obtain beams of Ar+ with currents 20~150 mA (current density 0.5~3.5 mA/cm2) and energy 200~2500eV at HF power level 10~150 W. Using Ar as a working gas it is possible to obtain thrust within 3~8 mN. Contact angles for untreated films were over 95$^{\circ}$ and 80 for Pet, 10o for PMMA and 12o for PI samples as a condition of ion assisted reaction at the ion dose of 10$\times$1016 ions/cm2, the ion beam potential of 1.2 keV and 4 ml/min for environmental gas flow rate. 900o peel tests yielded values of 15 to 35 for PET, 18 to 40 and 12 to 36 g/min. respectively. High resolution X-ray photoelectron spectrocopy is the Cls region for Cu metal on these polymer substrates showed increases in C=O-O groups for polymide, whereas PET and PMMA treated samples showed only C=O groups with increase the ion dose. Finally, unstable polymer surface can be changed from hydrophobic to hydrophilic formation such as C-O and C=O that were confirmed by the XPS analysis, conclusionally, the ion assisted reaction is very effective tools to attach reactive ion species to form functional groups on C-C bond chains of PET, PMMA and PI.

  • PDF

Adjunctive Therapy of Pimecrolimus for Treatment of Facial Discoid Lupus Erythematosus in a Dog

  • Yeonhoo Jung;Moonseok Jang;Rahye Kang;Wanghui Lee;Seongjun Park
    • 한국임상수의학회지
    • /
    • 제41권1호
    • /
    • pp.49-53
    • /
    • 2024
  • A two-year-old, spayed female, 22.5 kg Pungsan was referred with chronic crusts and erosion on the nose. A referring veterinarian prescribed an anti-inflammatory dose (0.5-1 mg/kg/day) of oral glucocorticoids for 5 months, but skin lesions showed no meaningful improvement. A dermatological evaluation revealed a crust, depigmentation, erosion, and erythematous lesion over the nasal planum with a loss of the normal cobblestone texture. Also, firm and multifocal plaques over the thigh, groin, axilla, and dorsum were detected. A cytology examination on the nose, thigh, groin, axilla, and dorsum revealed moderate neutrophilic inflammation and bacterial infection. Abdominal radiography and ultrasonography revealed subcutaneous calcified materials along the thigh, groin, axilla, and dorsum. Calcinosis cutis was suspected because of the adverse effect of previous prolonged corticosteroid therapy. A histopathology examination of the nose lesion revealed moderate to severe degenerative or apoptotic changes of the basal layer and lymphoplasmacytic interface dermatitis. Facial discoid lupus erythematosus (FDLE) was diagnosed based on the history and the clinical, cytological, and histopathological results. Minocycline (7 mg/kg PO q 12 h) and niacinamide (500 mg/dog PO q 12 h) were prescribed as initial treatment. Glucocorticoids were not administered due to the presence of calcinosis cutis induced by previous corticosteroid treatment. After 6 weeks of treatment, the clinical signs on the nose were mildly improved. At this time, topical 1% pimecrolimus cream (twice daily) was initiated, while minocycline and niacinamide were continued at the same dose. The nasal planum markedly improved after 6 weeks of additional treatment, hence minocycline and niacinamide were prescribed for an additional 2 weeks and stopped, and the patient was continued solely on topical pimecrolimus. The dog's skin lesion has been maintained in clinical remission with topical 1% pimecrolimus twice daily for more than 5 months.