• Title/Summary/Keyword: Interface detection

Search Result 538, Processing Time 0.03 seconds

A study on User experience of Virtual Beauty Makeup Applications (가상 뷰티 메이크업 애플리케이션의 사용자 경험 연구)

  • Woo, Ji-Hye;Kim, Seung-In
    • Journal of Digital Convergence
    • /
    • v.18 no.11
    • /
    • pp.459-464
    • /
    • 2020
  • This study is a study that analyzes the user experience of a virtual makeup application in the beauty industry where color or formulation testing is important. Recently, cases of beauty smart stores and beauty applications using AR and AI are increasing. However, since virtual makeup is different from testing a real product, it is necessary to derive needs through research from the user's side. In order to compare user preferences by using AR and AI cases, six factors based on the emotional interface model were analyzed through a questionnaire to identify items with statistically significant figures. As a result, the user felt comfortable with the virtual makeup function, but showed that it needs to be supplemented in terms of reliability. Since this study focused on the customer experience as a real user and identified the main experience factors and needs of virtual makeup through two types of comparison, it is hoped that this study will be useful as a prior study.

Determination of Trace Amounts of Zirconium by Flotation - Spectrophotometric Method (부유 - 분광광도법에 의한 지르코늄의 극미량 측정)

  • Pourreza, N.;Parham, H.;Shiri, S.
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.3
    • /
    • pp.283-286
    • /
    • 2010
  • A sensitive and reproducible method for the flotation-spectrophotometric determination of zirconium is reported. The method is based on the complex formation zirconium and xylenol orange (XO) which is floated in the interface of aqueous phase and n-hexane by vigorous shaking. By discarding the aqueous solution and n-hexane, the adsorbed complex on to the wall of a separating funnel was dissolved in a small volume of methanol solvent and its absorbance was measured at 429 nm. The effect of different parameters such as pH, concentrations of HCl, and XO, and volume of n-hexane flotation dissolvent, standing and shaking time were studied. The calibration curve was linear in the range of 7-120 ng $mL^{-1}$ of zirconium with a correlation coefficient of 0.9991. The limit of detection (LOD) was 5.8 ng $mL^{-1}$. The relative standard deviation (RSD) for seven replicate measurements of 50 and 110 ng $mL^{-1}$ of zirconium were 4.4 and 3.0%, respectively. The method was successfully applied to the determination of zirconium in water samples.

Development and Performance of a Hand-Held CZT Detector for In-Situ Measurements at the Emergency Response

  • Ji, Young-Yong;Chung, Kun Ho;Kim, Chang-Jong;Yoon, Jin;Lee, Wanno;Choi, Geun-Sik;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.87-91
    • /
    • 2016
  • Background: A hand-held detector for an emergency response was developed for nuclide identification and to estimate the information of the ambient dose rate in the scene of an accident as well as the radioactivity of the contaminants. Materials and Methods: To achieve this, the most suitable sensor was first selected as a cadmium zinc telluride (CZT) semiconductor and the signal processing unit from a sensor and the signal discrimination and storage unit were successfully manufactured on a printed circuit board. Results and Discussion: The performance of the developed signal processing unit was then evaluated to have an energy resolution of about 14 keV at 662 keV. The system control unit was also designed to operate the CZT detector, monitor the detector, battery, and interface status, and check and transmit the measured results of the ambient dose rate and radioactivity. In addition, a collimator, which can control the inner radius, and the airborne dust sampler, which consists of an air filter and charcoal filter, were developed and mounted to the developed CZT detector for the quick and efficient response of a nuclear accident. Conclusion: The hand-held CZT detector was developed to make the in-situ gamma-ray spectrometry and its performance was checked to have a good energy resolution. In addition, the collimator and the airborne dust sampler were developed and mounted to the developed CZT detector for a quick and efficient response to a nuclear accident.

Development of an Intelligent Software Programmable Logic Controller for IEC1131-3 International Standard Languages (IEC1131-3 표준언어 처리를 위한 지능적 소프트웨어 PLC 개발)

  • Cho, Young-Im
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.2
    • /
    • pp.207-215
    • /
    • 2004
  • The PLC programming by IEC1131-3 is hard to handle to ordinary users as well as professionals. Also it has not a generality, so that it couldn't be debugging some logic errors easily. In order to be adapted for such environment, In this paper, I have developed the ISPLC(Intelligent Agent System based Software Programmable Logic Controller). In ISPLC system, LD programmed by a user is converted to the C code which can be used in a commercial editor such as Visual C++. The detection of logical errors in C code is more effective than PLC programming itself. ISPLC provides the GUI-based interface in web environment and an easy programming platform to such beginners as well as professionals. The study of code conversion of LD to IL as well as IL to C is firstly tried in the world as well as KOREA. To show the effectiveness of the developed system, I applied it to a practical case, a real time traffic control system. ISPLC is minimized the error debugging and programming time owing to be supported by windows application programs.

Performance Comparison of CDMA and TDMA protocols in radio access system for Integrated Voice/Data Services (음성 및 데이터서비스를 위한 무선접속시스템에서 CDMA와 TDMA방식의 성능비교)

  • 고종하;양영님;이정규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.6A
    • /
    • pp.820-831
    • /
    • 1999
  • In this paper, we have compared the performance of a D-TDMA protocol with that of a CDMA protocol, in radio access system for integrated voice/data services.The D-TDMA protocol is based on a generic dynamic channel assignment approach to be followed a combination of “circuit mode” reservation for voice calls, along with dynamic first-come-first served assignment of remaining capacity for data messages. In the CDMA protocol, we have used the voice activity detection to reduce the interface power of other mobiles in internal and external cells, and analyzed the interference power ratio. Also we have computed BER(Bit Error Rate) by using this interference power ratio and evaluated voice blocking probability(voice packet loss probability) and data transmission delay, according to average data length and average data arrival rate.We have found the CDMA protocol achieves comparatively higher performance for short data length, regardless of data arrival rate. Otherwise, the data transmission delay of D-TDMA protocol is shorter than that of the CDMA protocol for long data message.

  • PDF

Real-Time Object Recognition Using Local Features (지역 특징을 사용한 실시간 객체인식)

  • Kim, Dae-Hoon;Hwang, Een-Jun
    • Journal of IKEEE
    • /
    • v.14 no.3
    • /
    • pp.224-231
    • /
    • 2010
  • Automatic detection of objects in images has been one of core challenges in the areas such as computer vision and pattern analysis. Especially, with the recent deployment of personal mobile devices such as smart phone, such technology is required to be transported to them. Usually, these smart phone users are equipped with devices such as camera, GPS, and gyroscope and provide various services through user-friendly interface. However, the smart phones fail to give excellent performance due to limited system resources. In this paper, we propose a new scheme to improve object recognition performance based on pre-computation and simple local features. In the pre-processing, we first find several representative parts from similar type objects and classify them. In addition, we extract features from each classified part and train them using regression functions. For a given query image, we first find candidate representative parts and compare them with trained information to recognize objects. Through experiments, we have shown that our proposed scheme can achieve resonable performance.

A Study on Degradation Characteristic of High Strength Fire Resistance Steel for Frame Structure by Acoustic Emission (음향방출법에 의한 고강도 구조용 내화강의 열화특성에 관한 연구)

  • Kim, H.S.;Kang, C.Y.;Nam, K.W.;Kim, B.A.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.5
    • /
    • pp.309-317
    • /
    • 2000
  • Demand for new nondestructive evaluations is growing to detect tensile crack growth behavior to predict long term performance of materials and structure in aggressive environments, especially when they are in non-visible area. Acoustic emission technique is well suited to these problems and has drawn a keen interests because of its dynamic detection ability, extreme sensitivity and location of growing defects. In this study, we investigated the strength of fire resistance steel for frame structure by tensile test after degradation treatment and analysed acoustic emission signals obtained from tensile test with time frequency analysis methods. In the T and TN specimens(under $600^{\circ}C$-10min ) consisting of ferrite and pearlite structure, most of acoustic emission events were produced near yield point, mainly due to the dislocation activities during the deformation. However, B specimen under $600^{\circ}C$-10min had a two peak which was attribute to the presence of martensite phase. The first peak is before yield point and the second after yield point. The sources of second acoustic emission peak were the debonding of martensite-martensite interface and the micro-cracking of brittle martensite phase. In $600^{\circ}C$-30min to $700^{\circ}C$-60min, many signals were observed before yield point and were decreased after yield point.

  • PDF

Detection of Acoustic Signal Emitted during Degradation of Lithium Ion Battery (리튬이온전지의 열화손상에 의한 음향방출 신호 검출)

  • Choi, Chan-Yang;Byeon, Jai-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.198-204
    • /
    • 2013
  • Acoustic emission(AE) signal was detected during charge and discharge of lithium ion battery to investigate relationships among cumulative count, discharge capacity, and microdamages. AE signal was received during accelerated charge/discharge cycle test of a coin-type commercial battery. A number of AE signals were successfully detected during charge and discharge, respectively. With increasing number of cycle, discharge capacity was decreased and AE cumulative count was observed to increase. Microstructural observation of the decomposed battery after cycle test revealed mechanical damages such as interface delamination and microcracking of the electrodes. These damages were attributed to sources of the detected AE signals. Based on a linear correlation between discharge capacity and cumulative count, feasibility of AE technique for evaluation of battery degradation was suggested.

A Study On Positioning Of Mouse Cursor Using Kinect Depth Camera (Kinect Depth 카메라를이용한 마우스 커서의 위치 선정에 관한 연구)

  • Goo, Bong-Hoe;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.478-484
    • /
    • 2014
  • In this paper, we propose new algorithm for positioning of mouse cursor using fingertip direction on kinect depth camera. The proposed algorithm uses center of parm points from distance transform when fingertip point toward screen. Otherwise, algorithm use fingertip points. After image preprocessing, the center of parm points is calculated from distance transform results. If the direction of the finger towards the camera becomes close to the distance between the fingertip point and center of parm point, it is possible to improve the accuracy of positioning by using the center of parm point. After remove arm on image, the fingertip points is obtained by using a pixel on the long distance from the center of the image. To calculate accuracy of mouse positioning, we selected any 5 points. Also, we calculated error rate between reference points and mouse points by performed 500 times. The error rate results could be confirmed the accuracy of our algorithm indicated an average error rate of less than 11%.

The Evaluation of the thermal degradation and the degree of cure of glass/epoxy composite by ultrasonic technique (복합재료의 열화도 및 경화도에 따른 초음파 특성 연구)

  • 강길호;최원종;박상윤
    • Composites Research
    • /
    • v.16 no.6
    • /
    • pp.33-40
    • /
    • 2003
  • The initial thermal degradation of polymer matrix composite is not observed easily. At the beginning of thermal degradation of polymer matrix composites, phase transformation such as chain scission, oxidation occur, and then micro delamination is produced in matrix and interface between matrix and fiber before blistering. Initial heat damage deteriorate mechanical properties of composites. We presented the detection method of the initial heat damage of composites conveniently using ultrasonic technique. Absorption coefficient and material velocity was measured with thermal degradation and degree of cure. The more thermal degradation was progressed, the more absorption coefficient was increased. When the cure temperature is more high, the absorption coefficient of cured composite is increased and material velocity is decreased. We concluded that cure temperature is more high, the defects such as void is increased and molecular structure cured at high temperature has cross-linking structure which is more absorb the ultrasonic waves.