Design of the Receiver for AAL Type 2 Switch (AAL 유형 2 스위치용 수신부 설계)

  • 손승일
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.205-208
    • /
    • 2002
  • An existing ATM switch fabric uses VPI(Virtual Path Identifier) and VCI(Virtual Channel Identifier) information to route ATM cell. But AAL type 2 switch which efficiently processes delay-sensitive, low bit-rate data such as a voice routes the ATM cell by using CID(Channel Identification) field in addition to VPI and VCI. In this paper, we research the AAL type 2 switch that performs the process of CPS packet. The Receive unit extracts the CPS packet from the inputted ATM cell. The designed receive unit consists of input FIFO, r)( status table, CAM(Content Addressable Memory), new CID table and partial packet memory. Also the designed receive unit supports the PCI interface with host processor. The receive unit is implemented in Xilinx FPGA and operates at 72MHz.

  • PDF

Interface shear strength between Crushed Stone and Geotextile (쇄석-지오텍스타일간의 접촉면 전단강도 산정)

  • Lee, Seok-Won;Youn, Choo-Moon;An, Hyun-Ho;Seo, Byoung-Wook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.1
    • /
    • pp.33-38
    • /
    • 2006
  • Large-scale direct shear tests were conducted in order to evaluate both the shear strength of crushed stone itself and the interface shear strength between crushed stone and geotextile. Total three types of geotextile (i.e. one woven geotextile and two nonwoven geotextiles) were used in the experimental program, considering two different values for the unit weight of crushed stone. Total fifteen tests were conducted in this study. It has been found from the experimental results that the friction angles of crushed stone itself were $47^{\circ}$ and $57^{\circ}$ under the unit weights of crushed stone being $1.4t/m^3$ and $1.5t/m^3$, respectively. Interface friction angle between nonwoven geotextile and crushed stone showed $39^{\circ}$ for type A indicating an efficiency of 83% and $42^{\circ}$ for type B indicating an efficiency of 89%. Similarly, interface friction angle between woven geotextile and crushed stone showed $39^{\circ}$ indicating an efficiency of 83%.

  • PDF

Extended-FEM for the solid-fluid mixture two-scale problems with BCC and FCC microstructures

  • Sawada, Tomohiro;Nakasumi, Shogo;Tezuka, Akira;Fukushima, Manabu;Yoshizawa, Yu-Ichi
    • Interaction and multiscale mechanics
    • /
    • v.2 no.1
    • /
    • pp.45-68
    • /
    • 2009
  • An aim of the study is to develop an efficient numerical simulation technique that can handle the two-scale analysis of fluid permeation filters fabricated by the partial sintering technique of small spherical ceramics. A solid-fluid mixture homogenization method is introduced to predict the mechanical characters such as rigidity and permeability of the porous ceramic filters from the micro-scale geometry and configuration of partially-sintered particles. An extended finite element (X-FE) discretization technique based on the enriched interpolations of respective characteristic functions at fluid-solid interfaces is proposed for the non-interface-fitted mesh solution of the micro-scale analysis that needs non-slip condition at the interface between solid and fluid phases of the unit cell. The homogenization and localization performances of the proposed method are shown in a typical two-dimensional benchmark problem whose model has a hole in center. Three-dimensional applications to the body-centered cubic (BCC) and face-centered cubic (FCC) unit cell models are also shown in the paper. The 3D application is prepared toward the computer-aided optimal design of ceramic filters. The accuracy and stability of the X-FEM based method are comparable to those of the standard interface-fitted FEM, and are superior to those of the voxel type FEM that is often used in such complex micro geometry cases.

EPGA Implementation and Verification of CSIX Module (CSIX 모듈의 FPGA 구현 및 검증)

  • 김형준;손승일;강민구
    • Journal of Internet Computing and Services
    • /
    • v.3 no.5
    • /
    • pp.9-17
    • /
    • 2002
  • CSIX-L1 is the Common Switch Interface that defines a physical interface for transferring information between a traffic manager (Network Processor) and a switching fabric in ATM, IP, MPLS, Ethernet and data communication areas. In Tx, data to be transmitted is generated in Cframe which is the base information unit and in Rx, original data is extracted from the received Cframe. CSIX-L1 suppots the 32, 64, 96, and 123-bit interface and generates a variable length CFrame and Idle Cframe. Also CSIX-L1 appends Padding byte and supports 16-bit Vertical parity, CSIX-L1 is designed using Xilinx 4,1i. After functional and timing simulations are completed. CSIX-L1 module is downloaded in Xilinx FPGA XCV1000EHQ240C and verified. The synthesized CSIX module operates at 27MHz.

  • PDF

Molecular Interaction Interface Computing Based on Voxel Map (복셀맵을 기반으로 한 분자 간 상호작용 인터페이스의 계산)

  • Choi, Jihoon;Kim, Byungjoo;Kim, Ku-jin
    • Journal of the Korea Computer Graphics Society
    • /
    • v.18 no.3
    • /
    • pp.1-7
    • /
    • 2012
  • In this paper, we propose a method to compute the interface between protein molecules. When a molecules is represented as a set of spheres with van der Waals radii, the distance from a spatial point p to the molecule corresponds to the distance from p to the closet sphere. The molecular interface is composed of equi-distant points from two molecules. Our algorithm decomposes the space into a set of voxels, and then constructs a voxel map by storing the information of spheres intersecting each voxel. By using the voxel map, we compute the distance between a point and the molecule. We also use GPU for the parallel processing, and efficiently approximate the interface of a pair of molecules.

Simulation of fracture in plain concrete modeled as a composite material

  • Bui, Thanh T.;Attard, Mario M.
    • Computers and Concrete
    • /
    • v.2 no.6
    • /
    • pp.499-516
    • /
    • 2005
  • A composite model is used to represent the heterogeneity of plain concrete consisting of coarse aggregates, mortar matrix and the mortar-aggregate interface. The composite elements of plain concrete are modeled using triangular finite element units which have six interface nodes along the sides. Fracture is captured through a constitutive single branch softening-fracture law at the interface nodes, which bounds the elastic domain inside each triangular unit. The inelastic displacement at an interface node represents the crack opening or sliding displacement and is conjugate to the internodal force. The path-dependent softening behaviour is developed within a quasi-prescribed displacement control formulation. The crack profile is restricted to the interface boundaries of the defined mesh. No re-meshing is carried out. Solutions to the rate formulation are obtained using a mathematical programming procedure in the form of a linear complementary problem. An event by event solution strategy is adopted to eliminate solutions with simultaneous formation of softening zones in symmetric problems. The composite plain concrete model is compared to experimental results for the tensile crack growth in a Brazilian test and three-point bending tests on different sized specimens. The model is also used to simulate wedge-type shear-compression failure directly under the loading platen of a Brazilian test.

Design and Implementation of Low Power Touch Screen Controller for Mobile Devices (모바일용 저전력 터치 스크린 제어 회로 설계 및 구현)

  • Park, Sang-Bong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.279-283
    • /
    • 2012
  • In is paper, we design and implement the low power, high speed touch screen controller that calculates and outputs the coordinate of touch point on the touch screen of mobile devices. The system clock is 10HMz, the number of input channels is 21, standby current is $20{\mu}A$, dynamic range of input is 140pF~400pF and the response time is 0.1ms/frame. It contains the power management unit for low power, automatic impedance calibration unit in order to adapt to humidity, temperature and evaluation board, adjacent key and pattern interference suppression unit, serial interface unit of I2C and SPI. The function and performance is verified by using FPGA and $0.18{\mu}m$ CMOS standard process. The implemented touch screen is designed for using in the double layer ITO(Indium Thin Oxide) module with diamond pattern and single layer ITO module for cost-effective which are applied to mobile phone or smart remote controller.

Real-time Parallel Processing Simulator for Modeling Portable Missile System and Performance Analysis (휴대용 유도탄 체계의 모델링과 성능분석을 위한 실시간 병렬처리 시뮬레이터)

  • Kim Byeong-Moon;Jung Soon-Key
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.4 s.42
    • /
    • pp.35-45
    • /
    • 2006
  • RIn this paper. we describe real-time parallel processing simulator developed for the use of performance analysis of rolling missiles. The real-time parallel processing simulator developed here consists of seeker emulator generating infrared image signal on aircraft, real-time computer, host computer, system unit, and actual equipments such as auto-pilot processor and seeker processor. Software is developed according to the design requirements of mathematic model, 6 degree-of-freedom module, aerodynamic module which are resided in real-time computer. and graphic user interface program resided in host computer. The real-time computer consists of six TI C-40 processors connected in parallel. The seeker emulator is designed by using analog circuits coupled with mechanical equipments. The system unit provides interface function to match impedance between the components and processes very small electrical signals. Also real launch unit of missiles is interfaced to simulator through system unit. In order to use the real-time parallel processing simulator developed here as a performance analysis equipment for rolling missiles, we perform verification test through experimental results in the field.

  • PDF

A Study on the Development of Urine Analyzer System (뇨분석 시스템 개발에 관한 연구)

  • Lee, S.J.;Choi, B.C.;Kim, K.N.;Hong, S.I.;Kim, J.H.;Kim, J.H.;Jun, K.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.303-308
    • /
    • 1997
  • In this paper, we analyzed the spectroscopic properties of strip to analyzer urine qualitatively & quantitatively and make urine analyzer system stable by spectroscopy, and research the property of preamplifier unit. The analysis of spectroscopic properties of 10 pads in the strip is used for determine the wave length of light source of optic detector unit and used for basic materials which are necessary that we develop the algorithm analyzing the density grade of pad accurately. We make preamplifier unit by using the current to frequency method to measure the distribution of pad color. We implemented urine analyzer system. This system's hardware is composed of measuring unit for detect of distribution density of strip pad, main processing unit, communication unit, interface device, thermal printer, and indicator. The software consists of the program which manage the argument of test, proportion initial value of urine analyzer and calibrate analyzed result.

  • PDF

Design and Implementation for Motion Control System with Precise Driving Mechanism (정밀구동메커니즘 적용 모션제어시스템 설계 및 구현)

  • Lee, Sang-Kyung;Lee, Jun-Yeong;Choi, Yun-Seok;Park, Hong Bea
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.3
    • /
    • pp.129-136
    • /
    • 2013
  • In this paper, a motion control system based on 2-axis gimbal system is designed and implemented to drive a high speed and precision. The proposed system consists of the RS-422 interface, 2-axis gimbal platform, servo control unit integrated with a high speed DSP chip-set, servo amplifier unit, potentiometer sensor unit, and resolver sensor unit. The servo control unit using the high speed DSP firmware is designed to get a fast response without an overshoot with step input and a RMS error of low probability with ramp input. The servo amplifier unit using a voltage control is designed to resolve the zero-crossing distortion for precise motion. To verify the performance and stability of the implemented system, experiments are performed through a measurement of the time and frequency domain response in a laboratory environment by using a PXI(PCI eXtentions for Instrumentation).