• Title/Summary/Keyword: Interface Pressure

Search Result 1,042, Processing Time 0.041 seconds

Relationships Between the Transfemoral Socket Interface Pressure and Myoelectric Signal of Residual Limb During Gait

  • Hong, J.H.;Lee, J.Y.;Chu, J.U.;Lee, J.Y.;Mun, M.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1070-1073
    • /
    • 2002
  • The biomechanical interaction between the stump and the prosthetic socket is critically important to achieve close-to-normal ambulation. Many investigators suggested that the pressure changes during gait of transfemoral amputees are closely related to the prosthetic alignment, the socket shape, the stump size, and the residual muscle activity. The effects of the prosthetic alignment, the socket shape, and the stump size on the interface pressure were investigated previously. However, there is no report how the residual muscle activities in the transfemoral stump affect the socket interface pressure characteristics during gait. Since designs of socket fur lower limb amputees need to consider the socket interface pressure characteristics, the interface pressure patterns by the residual muscle activities during gait should be investigated. In this study, myoelectric signals (MES) and socket interface pressure in residual limb of transfemoral amputees were measured during the stance and swing phases of gait. For the purpose, specially designed quadrilateral sockets that MES electrodes could be instrumented were fabricated. A total of two transfemoral amputees were participated in the experiments. The measured temporal MES amplitude and interface pressure in knee flexor (biceps femoris) and extensor (rectus femoris) had significant correlations (P < 0.05). Based on the test results, It was suggested that the residual muscle activity of transfemoral amputees stump is an important factor affecting socket pressure changes during walk.

  • PDF

Factors Predicting the Interface Pressure Related to Pressure Injury in Intensive Care Unit Patients (중환자실 환자의 욕창 관련 경계압력 예측요인)

  • Shine, Ji Seon;Kim, Soo Jin;Lee, Ji Hyun;Yu, Mi
    • Journal of Korean Academy of Nursing
    • /
    • v.47 no.6
    • /
    • pp.794-805
    • /
    • 2017
  • Purpose: Interface pressure is a factor that contributes to the occurrence of pressure injuries. This study aimed to investigate interface pressure at common sites of pressure injury (occipital, gluteal and peritrochanteric areas), to explore the relationships among risk factors, skin condition and interface pressure, and to identify risk factors influencing interface pressure. Methods: A total of 100 patients admitted to the intensive care unit were enrolled at a tertiary teaching hospital in Korea. Interface pressure was recorded by a scanning aid device (PalmQ). Patient data regarding age, pulmonary disease, Braden Scale score, body mass index, serum albumin, hemoglobin, mean blood pressure, body temperature, and oxygen saturation were included as risk factors. Data collected from July to September 2016 were analyzed using binary logistic regression. Results: The mean interface pressure of the occipital, gluteal, and right and left peritrochanteric areas were 37.96 (${\pm}14.90$), 41.15 (${\pm}16.04$), 53.44(${\pm}24.67$), and 54.33 (${\pm}22.80$) mmHg, respectively. Predictive factors for pressure injuries in the occipital area were age ${\geq}70$ years (OR 3.45, 95% confidence interval [CI]: 1.19~9.98), serum albumin deficit (OR 2.88, 95% CI: 1.00~8.26) and body temperature ${\geq}36.5^{\circ}C$ (OR 3.12, 95% CI: 1.17~8.17); age ${\geq}70$ years (OR 2.81, 95% CI: 1.10~7.15) in the right peritrochanteric area; and body temperature ${\geq}36.5^{\circ}C$ (OR 2.86, 95% CI: 1.17~6.98) in the left peritrochanteric area. Conclusion: Our findings suggest that old age, hypoalbuminemia, and high body temperature may be contributory factors to increasing interface pressure; therefore, careful assessment and nursing care of these patients are needed to prevent pressure injury. Further studies are needed to establish cutoff values of interface pressure for patients with pressure ulcers.

A Bonding Surface Behavior of Bi-metal Bar through Hydrostatic Extrusion (이중복합봉 정수압 압출시 접합면 거동에 관한 연구)

  • Park, Hun-Jae;Na, Gyeong-Hwan;Jo, Nam-Seon;Lee, Yong-Sin
    • Transactions of Materials Processing
    • /
    • v.7 no.1
    • /
    • pp.66-71
    • /
    • 1998
  • The present study is concerned with the hydrostatic extrusion process of copper-clad aluminium bar to investigate the bonding conditions as well as the basic flow characteristics. Considering the bonding mechanism of bi-metal contact surface as cold pressure welding the normal pressure and the contact surface expansion are selected as process parameters governing the bonding conditions, in this study the critical normal pressure required for the local extrusion-the protrusion of virgin surfaces by the surface expansion at the interface-is obtained using a slip line method and is then used as a criteron for the bonding. A rigid plastic finite element method is used to analyze the steady state extrusion process. The interface profile of bi-metal rod is predicted by tracking the paths of two particles adja-process. The interface profile of bi-metal rod is predicted by tracking the paths of two particles adja-cent to interface surface. The contact surface area ration and the normal pressure along the interface are calculated and compared to the critical normal pressure to check bonding. It is found that the model predictions are generally in good agreement with the experimental observations. The compar-isons of the extrusion pressure and interface profile by the finite element with those by experi-ments are also given.

  • PDF

Study on the Relationship between Vascular Perfusion and Interface Pressure under the Ischial Tuberosity in the Sitting Posture (앉은 자세에서 좌골결절의 접촉압력과 혈류량과의 관계에 대한 연구)

  • Heo H.;Bae T.S.;Lee S.M.;Kim S.K.;Kim K.H.;Mun M.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.645-646
    • /
    • 2006
  • Pressure-induced decubitus is a serious disease among the elderly people. Interface pressure occluding vascular perfusion is known to be a cause of decubitus. Therefore, it is essential to quantify the relationship between vascular perfusion and interface pressure among the elderly people. Nine elderly normal people ($57.8{\pm}5.6\;years,\;63.3{\pm}7.0kg,\;1.68{\pm}0.05m$) were participated. Pressure was applied on the ischial tuberosity in the sitting posture from 0mmHg to 135mmHg as capillary vascular perfusion was recorded. The average interface pressure to occlude vascular perfusion under the ischial tuberosity is 120mmHg. Vascular perfusion values at the capillary occlusion is often lower than 60% of the vascular perfusion at 15mmHg. Higher sampling number is required to have more accurate results.

  • PDF

Study on the V-t Characteristics of the Interface between Epoxy and Rubber According to the Condition of Surfaces (표면조건에 따른 에폭시/고무 계면의 V-t 특성에 관한 연구)

  • Bae, Duck-Kweon;Kim, Chung-Hyeok;Oh, Yong-Cheul;Kim, Jin-Sa;Shin, Cheol-Gee;Lee, Sung-Ill
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.174-175
    • /
    • 2006
  • In this paper, AC dielectric strength of the interface between Epoxy and EPDM (ethylene propylene diene terpolymer) was investigated. Air compress system was used to give pressure to the interface. Specimens were prepared in various ways to generate different surface conditions for each type of interface. Increasing interfacial pressure, decreasing surface roughness and spreading oil over surfaces improve the AC interfacial dielectric strength. Especially, the dielectric strength was saturated at certain interfacial pressure.

  • PDF

Dielectric Strength of Macro Interface between Epoxy and Rubber According to the Interface Condition (계면조건에 따른 에폭시와 고무 거시계면의 절연내력)

  • Oh, Yong-Cheul;Bae, Duck-Kweon;Kim, Jin-Sa;Kim, Chung-Hyeok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.12
    • /
    • pp.581-585
    • /
    • 2006
  • Macro interfaces between two different bulk materials which affect the stability of insulation system exist inevitably in the complex insulation system using in extra high voltage (EHV) electric devices. In this paper, Interface between epoxy and ethylene propylene diene terpolymer (EPDM) was selected as an interface in electrical insulation system and the AC dielectric strength of the interface was investigated. Air compress system was used to give pressure to the interface. Specimens were prepared in various ways to generate different surface conditions for each type of interface. Increasing interfacial pressure, decreasing surface roughness and spreading oil over surfaces improve the AC interfacial dielectric strength. Especially, the dielectric strength was saturated at certain interfacial pressure.

Characteristics of the Buttock Interface Pressure According to Wheelchair Propulsion Speed and Various Back Reclined Seating Position (휠체어 추진속도 및 등받이 경사각도에 따른 둔부 압력 변화 특성)

  • Kwon, Hyuk-Cheol;Kong, Jin-Yong
    • Physical Therapy Korea
    • /
    • v.12 no.2
    • /
    • pp.1-10
    • /
    • 2005
  • Pressure ulcers are serious complications of tissue damage that can develop in patients with diminished pain sensation and diminished mobility. Pressure ulcers can result in irreversible tissue damage caused by ischemia resulting from external loading. There are many intrinsic and extrinsic contributors to the problem, including interface tissue pressure, shear, temperature, moisture, hygiene, nutrition, tissue tolerance, sensory and motor dysfunction, disease and infection, posture, and body support systems. The purposes of this study were to investigate the relationship between buttock interface pressure and seating position, wheelchair propulsion speed. Seated-interface pressure was measured using the Force Sensing Array pressure mapping system. Twenty subjects propelled wheelchair handrim on a motor-driven treadmill at different velocities (40, 60, 80 m/min) and seating position used recline ($100^{\circ}$, $110^{\circ}$, $120^{\circ}$) with a wheelchair simulator. Interface pressure consists of average (mean of the pressure sensor values) and maximum pressure (highest individual sensor value). The results of this study were as follows; No significant correlation in maximum/average pressure was found between a static position and a 40 m/min wheelchair propulsion (p>.05). However, a significant increase in maximum/average pressure were identified between conditions of a static position and 60 m/min, and 80 m/min wheelchair propulsion (p<.05). No significant correlation in maximum pressure were found between a $90^{\circ}$ recline (neutral position) and a $100^{\circ}$, $110^{\circ}$, or $120^{\circ}$ recline of the wheelchair back (p>.05). No significant difference in average pressure was found between conditions of a $90^{\circ}$ recline and both a $100^{\circ}$ and $110^{\circ}$ recline of wheelchair back. However, a significant reduction in average pressure was identified between conditions of a $90^{\circ}$ and $120^{\circ}$ recline of wheelchair back (p<.05). This study has shown some interesting results that reclining the seat by $120^{\circ}$ reduced average interface pressure, including the reduction or prevention in edema. And interface pressure was greater during dynamic wheelchair propulsion compared with static seating. Therefore, the optimal seating position and seating system ought to provide postural control and pressure relief. We need an education on optimal seating position and a suitable propulsion speeds for wheelchair users.

  • PDF

Analysis for the influence of geometric characteristics on air-liquid interface with pressure (기하학적 구조에 따른 압력이 기체-액체 경계면에 미치는 특성 해석)

  • Heo, Pil-Woo;Park, In-Sub
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.213-213
    • /
    • 2011
  • Hydrophobic hairs of some insects make bubbles underwater. These bubbles makes possible for insects to breathe underwater. In this thesis, influence of geometric characteristics on air-liquid interface with pressure is investigated. Air-liquid interface shape with hair diameter over distance between hairs is analyzed This results expects to be used in the developments of artificial gill technology.

  • PDF

Digitized Pressure Sensor (디지탈 출력 압력 센서)

  • Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.419-421
    • /
    • 1996
  • We propose the digitized pressure sensor and the interface circuit to read directly the pressure signal in the digital form. The interface circuit has the control clock, comparator, and bit value decision circuit. The digitized sensor and interface circuit are integrated on the one chip using the post processing after IC fabrication. The dimension of the fabricated digitized pressure sensor is $3{\times}6{\times}1mm^3$.

  • PDF

A Study on the Relationship between Vascular Perfusion and Interface Pressure on the Ischial Tuberosity in the Sitting Posture (않은 자세에서 둔부 좌골결절의 접촉압력과 혈류량과의 관계에 대한 연구)

  • Heo, Hyun;Bae, Tae-Soo;Mun, Mu-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.7 s.196
    • /
    • pp.126-132
    • /
    • 2007
  • Pressure-induced decubitus is a serious disease among the elderly people. Interface pressure occluding vascular perfusion is known to be a cause of decubitus. Therefore, it is essential to quantify the relationship between vascular perfusion and interface pressure among the elderly people to understand more about decubitus. Nine healthy elderly people (57.8$\pm$ 5.6 years, 63.3$\pm$ 7.0kg, 1.68$\pm$ 0.05m) were participated. Three healthy young people (31.7$\pm$ 3.2 years, 74.7$\pm$ 8.4kg, 1.75$\pm$ 0.04m) were also examined to be compared with the elderly group. Capillary vascular perfusion on the ischial tuberosity was recorded in the sitting posture as pressures were applied from 15mmHg to 135mmHg. The average interface pressure to occlude vascular perfusion (the average occlusion pressure) under the ischial tuberosity was 115.7mmHg in the elderly group. This value was not significantly different from the average occlusion pressure of the young group. Obesity effect on the occlusion pressure was investigated among the elderly group. The result was not significantly different between the obesity and the normal group in this study. This is a preliminary study to unveil the complicated cause of pressure-induced decubitus associated with occlusion of vascular perfusion. More subjects are required for the future study.