• Title/Summary/Keyword: Interface Models

Search Result 839, Processing Time 0.037 seconds

A Study of Systems Engineering Process Model For the Cognitive Interface Design Process (시스템 엔지니어링 프로세스 모델에 기반한 인지 시스템 설계 프로세스 연구)

  • Cha, Woo Chang;Ra, Doo Wan;Choi, Yong Jin;Lee, Ji Young
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.9 no.2
    • /
    • pp.15-22
    • /
    • 2013
  • The aim of this study is to propose the design process suitable for developing the cognitive interface considering system engineering process (SEP) models. Due to the cognitive workload in an operation of HMS, some cognitive interfaces have been developed. It is somehow difficult to use the developed cognitive interface in real working environment since they often showed a conflict to stereotyped interface. So it is necessary to develop the design process suitable for the more operator-specific interface. Various SEP models were reviewed for selecting the suitable design process which might resolve the problem from design-specific interface. The suitable process for designing cognitive interface was proposed considering currently usable SEP models. The findings from the study may be helpful for systematic approach to designing cognitive interface in digitalized environment. The proposed design process would be applied for easily employing the cognitive interface in digitalized working environment such as main control room in nuclear power plant.

Finite element modelling of the shear behaviour of profiled composite walls incorporating steel-concrete interaction

  • Anwar Hossain, K.M.;Wright, H.D.
    • Structural Engineering and Mechanics
    • /
    • v.21 no.6
    • /
    • pp.659-676
    • /
    • 2005
  • The novel form of composite walling system consists of two skins of profiled steel sheeting with an in-fill of concrete. The behaviour of such walling under in-plane shear is important in order to utilise this system as shear elements in a steel framed building. Steel sheet-concrete interface governs composite action, overall behaviour and failure modes of such walls. This paper describes the finite element (FE) modelling of the shear behaviour of walls with particular emphasis on the simulation of steel-concrete interface. The modelling of complex non-linear steel-concrete interaction in composite walls is conducted by using different FE models. Four FE models are developed and characterized by their approaches to simulate steel-concrete interface behaviour allowing either full or partial composite action. Non-linear interface or joint elements are introduced between steel and concrete to simulate partial composite action that allows steel-concrete in-plane slip or out of plane separation. The properties of such interface/joint elements are optimised through extensive parametric FE analysis using experimental results to achieve reliable and accurate simulation of actual steel-concrete interaction in a wall. The performance of developed FE models is validated through small-scale model tests. FE models are found to simulate strength, stiffness and strain characteristics reasonably well. The performance of a model with joint elements connecting steel and concrete layers is found better than full composite (without interface or joint elements) and other models with interface elements. The proposed FE model can be used to simulate the shear behaviour of composite walls in practical situation.

Implemetation of STEP Standard Data Interface (SDAI) on Multiple Data Models (이종 데이터 모델에서의 STEP 표준 데이터 인터페이스(SDAI) 구현)

  • 권용국;유상봉
    • The Journal of Society for e-Business Studies
    • /
    • v.3 no.1
    • /
    • pp.1-22
    • /
    • 1998
  • SDAI (Standard Data Access Interface) is an interface specification of accessing various storage systems such as file systems and database management systems for STEP data. Using SDAI, both application program developers and CAD/CAM system developers can be relieved from dealing with STEP physical file or system dependent DBMS operations. In this paper, we present implementations of SDAI on different data models, i.e., relational, extended relational, and object-oriented. In order to implement SDAI, we need to translate the EXPRESS information model into target data models. The schema translation process for three different data models are compared and other implementation issues are discussed.

  • PDF

Finite element analyses of the stability of a soil block reinforced by shear pins

  • Ouch, Rithy;Ukritchon, Boonchai;Pipatpongsa, Thirapong;Khosravi, Mohammad Hossein
    • Geomechanics and Engineering
    • /
    • v.12 no.6
    • /
    • pp.1021-1046
    • /
    • 2017
  • The assessment of slope stability is an essential task in geotechnical engineering. In this paper, a three-dimensional (3D) finite element analysis (FEA) was employed to investigate the performance of different shear pin arrangements to increase the stability of a soil block resting on an inclined plane with a low-interface friction plane. In the numerical models, the soil block was modeled by volume elements with linear elastic perfectly plastic material in a drained condition, while the shear pins were modeled by volume elements with linear elastic material. Interface elements were used along the bedding plane (bedding interface element) and around the shear pins (shear pin interface element) to simulate the soil-structure interaction. Bedding interface elements were used to capture the shear sliding of the soil on the low-interface friction plane while shear pin interface elements were used to model the shear bonding of the soil around the pins. A failure analysis was performed by means of the gravity loading method. The results of the 3D FEA with the numerical models were compared to those with the physical models for all cases. The effects of the number of shear pins, the shear pin locations, the different shear pin arrangements, the thickness and the width of the soil block and the associated failure mechanisms were discussed.

A Study on the Electrical Circuit Model of the Electrode/Electrolyte Interface for Improving Electrochemical Impedance Fitting (전기화학적 임피던스 Fitting 개선을 위한 전극/전해질 계면의 전기회로 모델 연구)

  • Chang, Jong-Hyeon;Pak, Jung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1087-1091
    • /
    • 2007
  • Exact impedance modeling of the electrode/electrolyte interface is important in bio-signal sensing electrode development. Therefore, the investigation of the equivalent circuit models for the interface has been pursued for a long time by several researchers. Previous circuit models fit the experimental results in limited conditions such as frequency range, type of electrode, or electrolyte. This paper describes a new electrical circuit model and its capability of fitting the experimental results. The proposed model consists of three resistors and two constant phase elements. Electrochemical impedance spectroscopy was used to characterize the interface for Au, Pt, and stainless steel electrode in 0.9% NaCl solution. Both the proposed model and the previous model were applied to fit the measured impedance results for comparison. The proposed model fits the experimental data more accurately than other models especially at the low frequency range, and it enables us to predict the impedance at very low frequency range, including DC, using the proposed model.

A Test of Two Models for the Bacteria Flux across the Sediment/Water Interface in an Effluent-dominated Stream (하수처리 방류 소하천내 퇴적물로부터의 박테리아 유출 플럭스모델 비교)

  • Ahn, Jong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.2
    • /
    • pp.165-172
    • /
    • 2010
  • Treated sewage could enable growth by providing key nutrients or seeding the sediments with enterococci strains that can grow in the environment. This study is to test the hypothesis that the flux of bacteria into the water column is rate-limited by the transfer of bacteria across the sediment/water interface. Two conceptual models are derived for the transfer of bacteria to the water column from the sediment/water interface: convective diffusion of isolated bacteria and resuspension of particle-associated bacteria. The model predictions are directly tested together with field measurements of bacteria and sediment in an effluent-dominated stream where high concentrations of enterococci in this stream originate primarily from growth of the bacteria in stream sediments. The results reveal that high concentrations of enterococci in this stream are transported primarily by resuspension of particle-associated bacteria accumulated at the sediment/water interface, either in the form of bacterial aggregates or in the form of inorganic particles.

HIGH-ORDER POTENTIAL FLOW MODELS FOR HYDRODYNAMIC UNSTABLE INTERFACE

  • Sohn, Sung-Ik
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.16 no.4
    • /
    • pp.225-234
    • /
    • 2012
  • We present two high-order potential flow models for the evolution of the interface in the Rayleigh-Taylor instability in two dimensions. One is the source-flow model and the other is the Layzer-type model which is based on an analytic potential. The late-time asymptotic solution of the source-flow model for arbitrary density jump is obtained. The asymptotic bubble curvature is found to be independent to the density jump of the fluids. We also give the time-evolution solutions of the two models by integrating equations numerically. We show that the two high-order models give more accurate solutions for the bubble evolution than their low-order models, but the solution of the source-flow model agrees much better with the numerical solution than the Layzer model.

A Study on the Electrochemical Impedance Spectroscopy and the Electrical Circuit Model for the Electrode/Electrolyte Interface (전극/전해질 계면의 전기화학적 임피던스 측정 및 전기회로 모델 연구)

  • Chang, Jong-Hyeon;Hong, Jang-Won;Pak, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.274-275
    • /
    • 2007
  • The investigation of the equivalent circuit models for the electrode/electrolyte interface has been pursued for a long time by several researchers. Previous circuit models fit the experimental results in limited conditions such as frequency range, type of electrode, or electrolyte. This paper describes a new electrical circuit model and its capability of fitting the experimental results. Electrochemical impedance spectroscopy was used to characterize the interface for Au, Pt, and stainless steel electrode in 0.9% NaCl solution. Both the proposed model and the previous model were applied to fit the measured impedance results for comparison. The proposed model fits the experimental data more accurately than other models especially at the low frequency range, and it enables us to predict the impedance at very low frequency range, including DC, using the proposed model.

  • PDF

The Comparison of Bonded/Unbonded Stem-Cement Interface in Total Hip Replacement -Experimental Study (인공 고관절 전치환술에서 주대-시멘트 경계층의 접착 및 비접착 고정술의 비교를 위한 실험적 연구)

  • Han, J.H.;Yoon, Y.S.;Lee, J.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.951-955
    • /
    • 2001
  • The experimental comparison between bonded and unbonded types stem-cement interface was carried out on axisymmetric stem-cement-aluminum model of the femoral component of a total hip replacement. Human femur was modeled in non-tapered and tapered($7.5^{\circ}$) aluminum hollow cylinders to emulate the diaphyseal and metaphyseal segments of the femur. For unbonded type, we tested stems with three different taper angles($5^{\circ},\;7.5^{\circ},\;10^{\circ}$). In every case, the cement-aluminum interface was designed to endure 8MPa shear strength. (a measured value at cement-bone interface) We tested aluminum models under axial loading for both cases. As an experimental result, it was found that unbonded stem sustained more axial load as bonded stem in both cases, diaphyseal and metaphyseal models. The unbonded types failed in cement mantle under axial compressive load, while the bonded ones failed in shear at cement-aluminum interface. These results suggest that a polished stem will sustain much higher axial load than a roughened stem. And a polished stem will make more stable cement-bone interface that may promote better osteosythesis around the stem.

  • PDF

SMI Compatible Simulation Scheduler Design for Reuse of Model Complying with SMP Standard

  • Koo, Cheol-Hea;Lee, Hoon-Hee;Cheon, Yee-Jin
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.407-412
    • /
    • 2010
  • Software reusability is one of key factors which impacts cost and schedule on a software development project. It is very crucial also in satellite simulator development since there are many commercial simulator models related to satellite and dynamics. If these models can be used in another simulator platform, great deal of confidence and cost/schedule reduction would be achieved. Simulation model portability (SMP) is maintained by European Space Agency and many models compatible with SMP/simulation model interface (SMI) are available. Korea Aerospace Research Institute (KARI) is developing hardware abstraction layer (HAL) supported satellite simulator to verify on-board software of satellite. From above reasons, KARI wants to port these SMI compatible models to the HAL supported satellite simulator. To port these SMI compatible models to the HAL supported satellite simulator, simulation scheduler is preliminary designed according to the SMI standard.