• Title/Summary/Keyword: Inter-Rater reliability

Search Result 197, Processing Time 0.033 seconds

Intra-Rater Test-Retest Reliability of Ely's Test Using Smartphone in Patients With Lumbar Extension-Rotation Syndrome

  • Park, Kyue-Nam;Ha, Sung-Min;Chung, Sung-Dae;Kim, Si-Hyun;Jang, Jun-Hyeok
    • Physical Therapy Korea
    • /
    • v.19 no.4
    • /
    • pp.46-54
    • /
    • 2012
  • Ely's test is commonly used to assess rectus femoris muscle flexibility. however, a reliability limit of this test was demonstrated by a previous study. In this study, we present an alternative method using an application for a digital horizontal level in a smartphone (DHLS) to complement the reliability limit of Ely's test. The aim of this study was to examine the reliability of Ely's test using DHLS on the pelvis, compared to using visual observation (VO) of pelvic and hip motions. Nineteen patients with lumbar extension-rotation syndrome were recruited for this study. An examiner examined the rectus femoris flexibility (both pass/fail and goniometer scoring) through Ely's test using both DHLS and VO. A retest session was completed two hours later for within-day reliability and seven days later for between-day intra-rater test-retest reliability. Results showed higher Kappa values for pass/fail scoring and higher intraclass correlation coefficient values for goniometer scoring in Ely's test using DHLS, compared to using VO. Measurement error and Bland and Altman plots further demonstrated the degree of intra-rater variance during Ely's test using DHLS in a clinical setting, compared to using VO. These results demonstrated that Ely's test using DHLS showed acceptable reliability compared to using VO. Ely's test using DHLS could be widely used for measuring the rectus femoris muscle flexibility in patients with lumbar extension-rotation syndrome, although the inter-rater reliability needs to be established first.

Reliability of Modified Ashworth Scale Using a Haptic Robot Finger Simulating Finger Spasticity (손가락 경직을 모사하는 로봇 시뮬레이터를 이용한 경직도 검진의 신뢰도 평가)

  • Ha, Dokyeong;Park, Hyung-Soon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.2
    • /
    • pp.125-133
    • /
    • 2017
  • This paper presents the inter-rater reliability of finger spasticity assessment tested realized by using finger simulator that mimics finger spasticity of patients after a stroke. For controlling the simulator torque, finger spasticity was modeled, and the model parameters were obtained by measuring quantitative data while grading based on Modified Ashworth Scale (MAS). A robotic finger simulator was designed for mimicking finger spasticity. Evaluation of this simulator with the help of seven rehabilitation doctors showed that the simulator had a Cohen's kappa value of 0.619 for Metacarpophalangeal Joint and 0.514 for Proximal Interphalangeal Joint. Fleiss' kappa between raters is 0.513 for Metacarpophalangeal Joint and 0.486 for Proximal Interphalangeal Joint. Therefore, the spasticity assessment made by MAS grade system is not reliable owing to the subjectivity of the assessment. The proposed robotic simulator can be used as a training tool for improving the reliability of the spasticity assessment.

An Evaluation of the Reliability and Validity of the Automatic Pennation Angle Measuring Program (깃각 자동측정 프로그램의 신뢰도와 타당도 평가)

  • Kim, Jong-Soon
    • PNF and Movement
    • /
    • v.17 no.2
    • /
    • pp.329-337
    • /
    • 2019
  • Purpose: Ultrasound imaging is commonly used to measure the pennation angle of human skeletal muscles in vivo. However, manual assessment of the pennation angle using ultrasound images is subjective and time-consuming and requires a high level of examiner skill. The architectural analysis of human skeletal muscles is thus challenging. Automated approaches using image processing techniques are therefore required to estimate the pennation angle in ultrasound images. The purpose of this study was thus to assess the intra-tester and inter-tester reliability and validity of the pennation angle using an automatic measurement program. Methods: Twenty-two healthy young adults (mean age = 22.55 years) with no medical history of neurological or musculoskeletal disorders voluntarily participated in this study. Ultrasound imaging was used to measure the pennation angle of the gastrocnemius muscle at rest. One examiner acquired images from all the participants. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC) to estimate reliability. Validity was measured using Pearson's correlation coefficient. Results: The intra-rater reliability was excellent for the automatic pennation angle measuring program and the manual pennation angle assessment method (ICC>0.95). The inter-rater reliability was also excellent for both methods (ICC>0.93). All the correlation coefficients for the automatic pennation angle measuring program and the manual pennation angle assessment method were 0.79, which indicated a significantly positive correlation (p<0.05). Conclusion: Pennation angle measurement using the automatic pennation angle measuring program showed acceptable reliability and validity. This study therefore demonstrated that the automatic measuring program was able to automatically measure the pennation angle of skeletal muscles using ultrasound images, and thus made it easy to investigate skeletal muscle architecture.

Intra- and Inter-rater Reliabilities of Infrasternal Angle Measurement

  • Kim, Moon-Hwan;Weon, Jong-Hyuck
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.154-158
    • /
    • 2015
  • Purpose: The purpose of this study was to propose a new reference point for measurement of the infrasternal angle and to investigate the intra- and inter-rater reliabilities of infrasternal angle measurement using photographs. Methods: Twenty-four healthy male college students participated as subjects in this study. Photographs were taken of subjects in two postures, one standing with the shoulders relaxed and one standing with the shoulders at $150^{\circ}$ abduction. All photographs were analyzed using Image J software. Raters used the photographs to measure the infrasternal angle between the xiphoid process, the medial margin of rib and navel on the right and left sides. The reliability of the infrasternal angle measurement was assessed by means of intraclass correlation coefficients [ICC (3,1)]. The level of statistical significance was set at p<0.05. Results: The intra- and inter-rater reliabilities of the infrasternal angle measurement for the right side at rest were excellent (ICC=0.866 and 0.813, respectively), as were those for the left side at rest (ICC=0.919 and 0.846, respectively). At $150^{\circ}$ shoulder abduction, the intra- and inter-rater reliabilities for measurement of the infrasternal angle on the right side were excellent (ICC=0.972 and 0.778, respectively), as were those for the left side (ICC=0.914 and 0.826, respectively). Conclusion: These findings suggest that this technique can be successfully used to measure the infrasternal angle, thus suggesting a new reference point for determining the length of the internal oblique and external oblique muscles in clinical situations.

The inter-rater absolute reliability and validity of the Figure-of-8 Walk test in patients with chronic stroke (만성 뇌졸중 환자 8자 모양 경로 보행 검사의 측정자간·절대적 신뢰도와 타당도)

  • Park, Chang-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.467-474
    • /
    • 2017
  • To investigate the intra-rater absolute reliabilities and validity of the Figure of-Eight Walk test (F8WT) in patients with chronic stroke. A total of 36 subjects with chronic stroke participated in this study. The inter-rater reliability of F8WT was calculated using intra-class correlation coefficients($ICC_{2,1}$). Moreover, we used the standard error measurement (SEM) and the small real difference (SRD) to examine the absolute reliability indices. The validity was demonstrated by a spearman correlation of F8WT with Postural Assessment Scale for Storke(PASS) and Trunk Impairment Scale(TIS). The inter-rater reliability of F8WT was excellent; ICC2,1=0.95(0.91~0.97), acceptable SEM=1.02, and SRD=2.82. F8WT were also found to be significantly associated with PASS(r=-0.82) and TIS(r=-0.85). Therefore, F8WT is a reliable measurement tool and is correlated well with stroke-impairments, such as postural and trunk control. F8WT will be a useful tool in evaluating the walking performance of subjects with chronic stroke.

Analysis of Visual Sensibility Evaluation of Naturally Colored Organic Cotton: Identification of Reliability and Proper Scouring Method

  • Park, Jang-Woon;Chang, Yoon;Hong, Won-Gi;Lee, Myung-Eun;Han, Ah-Reum;Chae, Young-Joo;Cho, Gil-Soo;You, Hee-Cheon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.311-317
    • /
    • 2011
  • Objective: The present study was intended to identify (1) the intra- and inter-rater reliabilities of a visual sensibility evaluation protocol and (2) the effects of NaCOC color and scouring method on the visual sensibility of NaCOC. Thirty female participants(20s & 30s) were participated in the visual sensibility evaluation of NaCOC. Background: Interests in naturally colored organic cotton(NaCOC) increase rapidly in parallel with the social trend of eco-friendly living and wellbeing. Method: Three color sets (ivory, green, and coyote-brown) of NaCOC specimens including one untreated and four treated specimens($Na_2CO_3$; NaOH; enzyme; boiling water) were examined in the study. The visual sensibility evaluation was conducted by the test-retest method using nine pairs of bipolar visual sensibility adjectives(bright-dark; clear-murky; heavy-light; vivid-subdued; warm-cool; fresh-stale; strong-weak; showy-plain; and luxurious-cheap). Results: As a result of reliability of a visual sensibility evaluation protocol, inter-rater variability(average SD=1.06) of visual sensibility evaluation was more than 1.4 times the intra-rater variability(average SD=0.74). However, both the sensibility evaluation reliabilities did not show any systematic pattern of changes. Lastly, ANOVA and post-hoc analysis showed that preferred scouring methods for a visual sensibility adjective pair significantly vary depending on NaCOC color. Application: Both the reliability of visual sensibility evaluation protocol and the analysis of proper scoring method of NaCOC in the study would be useful information to design the affective textile.

Development of Outcome Indicators of Urinary Incontinence for Quality Evaluation in Long Term Care Hospitals (요양병원의 서비스 질 평가를 위한 요실금 결과 지표 개발)

  • Yoon, Ju-Young;Lee, Ji-Yun
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.1
    • /
    • pp.110-118
    • /
    • 2010
  • Purpose: To develop outcome indicators of urinary incontinence to measure quality of care in long term care hospitals in Korea. Methods: The draft indicators of urinary incontinence were developed from a literature review and clinical expert panel. A survey of medical records of 280 patients in 20 hospitals was conducted to test inter-rater reliability. Statistical analysis was done to test risk adjustment criteria, variation between hospitals, and stability of indicators, using assessment data from 77,918 patients in 623 hospitals. Results: The inter-rater reliability of items was high (Kappa range: 0.66- 0.92). Severe cognitive impairment (odds ratio [OR]: 3.15, confidence interval [CI]: 3.03-3.26) and total mobility activities of daily living (ADLs) dependency (OR: 4.85, CI: 4.72-4.98) increased the prevalence of urinary incontinence, thus they proved to be significant criteria to stratify high and low risk groups. The prevalence for low risk showed more substantial variation than the high risk group. The indicators were stable over one month. Conclusion: This study demonstrated the feasibility of outcome indicators of urinary incontinence. Improving the reliability of the patient assessment tool and refining the indicators through validation study is a must for future study.

Evaluation and Functionality Stems Extraction for App Categorization on Apple iTunes Store by Using Mixed Methods : Data Mining for Categorization Improvement

  • Zhang, Chao;Wan, Lili
    • Journal of Information Technology Services
    • /
    • v.17 no.2
    • /
    • pp.111-128
    • /
    • 2018
  • About 3.9 million apps and 24 primary categories can be approved on Apple iTunes Store. Making accurate categorization can potentially receive many benefits for developers, app stores, and users, such as improving discoverability and receiving long-term revenue. However, current categorization problems may cause usage inefficiency and confusion, especially for cross-attribution, etc. This study focused on evaluating the reliability of app categorization on Apple iTunes Store by using several rounds of inter-rater reliability statistics, locating categorization problems based on Machine Learning, and making more accurate suggestions about representative functionality stems for each primary category. A mixed methods research was performed and total 4905 popular apps were observed. The original categorization was proved to be substantial reliable but need further improvement. The representative functionality stems for each category were identified. This paper may provide some fusion research experience and methodological suggestions in categorization research field and improve app store's categorization in discoverability.

A Reliability Study on the Auditory-perceptual Evaluation of Parkinsonian Dysarthria (파킨슨증으로 인한 마비말장애의 청지각적 평가에 대한 신뢰도 연구)

  • Kim, Hyang-Hee;Lee, Mi-Sook;Kim, Sun-Woo;Lee, Won-Yong
    • Speech Sciences
    • /
    • v.11 no.4
    • /
    • pp.129-141
    • /
    • 2004
  • An auditory-perceptual evaluation has long been utilized in assessing dysarthric speech. The process involves subjective judgement and the results might vary depending on clinical experiences or training of listeners. This study aimed to investigate reliability of the auditory-perceptual evaluation of 22 multi -dimensional variables on 6 patients with Parkinsonian speech disorders. Listeners were divided into two groups: one consisted of 6 speech therapists with clinical experiences for three years or more, and the other 6 graduate students without any previous clinical background. The results showed that the former evaluated dysarthric speech with higher inter-rater and intra-rater reliabilities than the latter. Furthermore, such speech variables as 'precise consonant: 'speech intelligibility: and 'SMR regularity' were more influenced than others by clinical experiences. We, therefore, postulated that a reliable auditory-perceptual evaluation of dysarthric speech may require adequate amount of clinical training of listeners.

  • PDF

Reliability and Data Integration of Duplicated Test Results Using Two Bioelectrical Impedence Analysis Machines in the Korean Genome and Epidemiology Study

  • Park, Bo-Young;Yang, Jae-Jeong;Yang, Ji-Hyun;Kim, Ji-Min;Cho, Lisa-Y.;Kang, Dae-Hee;Shin, Chol;Hong, Young-Seoub;Choi, Bo-Youl;Kim, Sung-Soo;Park, Man-Suck;Park, Sue-K.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.6
    • /
    • pp.479-485
    • /
    • 2010
  • Objectives: The Korean Genome and Epidemiology Study (KoGES), a multicenter-based multi-cohort study, has collected information on body composition using two different bioelectrical impedence analysis (BIA) machines. The aim of the study was to evaluate the possibility of whether the test values measured from different BIA machines can be integrated through statistical adjustment algorithm under excellent inter-rater reliability. Methods: We selected two centers to measure inter-rater reliability of the two BIA machines. We set up the two machines side by side and measured subjects' body compositions between October and December 2007. Duplicated test values of 848 subjects were collected. Pearson and intra-class correlation coefficients for inter-rater reliability were estimated using results from the two machines. To detect the feasibility for data integration, we constructed statistical compensation models using linear regression models with residual analysis and R-square values. Results: All correlation coefficients indicated excellent reliability except mineral mass. However, models using only duplicated body composition values for data integration were not feasible due to relatively low $R^2$ values of 0.8 for mineral mass and target weight. To integrate body composition data, models adjusted for four empirical variables that were age, sex, weight and height were most ideal (all $R^2$ > 0.9). Conclusions: The test values measured with the two BIA machines in the KoGES have excellent reliability for the nine body composition values. Based on reliability, values can be integrated through algorithmic statistical adjustment using regression equations that includes age, sex, weight, and height.