• 제목/요약/키워드: Intensity-modulated

검색결과 420건 처리시간 0.023초

Trends in intensity-modulated radiation therapy use for rectal cancer in the neoadjuvant setting: a National Cancer Database analysis

  • Wegner, Rodney E.;Abel, Stephen;White, Richard J.;Horne, Zachary D.;Hasan, Shaakir;Kirichenko, Alexander V.
    • Radiation Oncology Journal
    • /
    • 제36권4호
    • /
    • pp.276-284
    • /
    • 2018
  • Purpose: Traditionally, three-dimensional conformal radiation therapy (3D-CRT) is used for neoadjuvant chemoradiation in locally advanced rectal cancer. Intensity-modulated radiation therapy (IMRT) was later developed for more conformal dose distribution, with the potential for reduced toxicity across many disease sites. We sought to use the National Cancer Database (NCDB) to examine trends and predictors for IMRT use in rectal cancer. Materials and Methods: We queried the NCDB from 2004 to 2015 for patients with rectal adenocarcinoma treated with neoadjuvant concurrent chemoradiation to standard doses followed by surgical resection. Odds ratios were used to determine predictors of IMRT use. Univariable and multivariable Cox regressions were used to determine potential predictors of overall survival (OS). Propensity matching was used to account for any indication bias. Results: Among 21,490 eligible patients, 3,131 were treated with IMRT. IMRT use increased from 1% in 2004 to 22% in 2014. Predictors for IMRT use included increased N stage, higher comorbidity score, more recent year, treatment at an academic facility, increased income, and higher educational level. On propensity-adjusted, multivariable analysis, male gender, increased distance to facility, higher comorbidity score, IMRT technique, government insurance, African-American race, and non-metro location were predictive of worse OS. Of note, the complete response rate at time of surgery was 28% with non-IMRT and 21% with IMRT. Conclusion: IMRT use has steadily increased in the treatment of rectal cancer, but still remains only a fraction of overall treatment technique, more often reserved for higher disease burden.

Evaluation of the Lens-absorbed Dose of the Scattered Radiation Generated During Tomotherapy IMRT to the H&N Cancer Patient

  • Choi, Jae-Won;Lee, Hae-Kag;Cho, Jae-Hwan;Choi, Cheon Woong;Ju, Myung Sik;Chang, Bok Soon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.141-145
    • /
    • 2017
  • This paper uses a glass dosimeter to evaluate the lens-absorbed dose of scattered radiation generated in tomotherapy intensity modulated radiation therapy (IMRT). The head and neck portion of the rando phantom was subjected to a CT scan. The tomotherapy plan was designed to ensure delivery of the prescribed total 70 Gy day 2.2 Gy. With the lens portion of the glass dosimeter, a 5mm bolus was subjected to the scattered radiation treatment, and the dose was measured in each of the three megavoltage CT (MVCT) modes. The result is multiplied by 30 times and was determined once as the mean value. The measurement at the MVCT Coarse mode is RT mode 10.797 mGy, that for the Normal mode is 13.360 mGy, for the Fine mode is a maximum of 22.872 mGy, and for the treatment mode is 895.830 mGy. A small amount of scattered radiation in the MVCT is measured in the lens scattered radiation, but scattered radiation during treatment was measured to be near 1 Gy on the lens. Compared to a one-time radiation treatment of 2.2 Gy, the survey showed something unexpected in that it was half the value of that research to the patient. Therefore, will be aware of how much of an influence there will be on sensitive organs, such as the lens by scattered radiation generated during intensity modulated radiation therapy.

Quantifications of Intensity-Modulated Radiation Therapy Plan Complexities in Magnetic Resonance Image Guided Radiotherapy Systems

  • Chun, Minsoo;Kwon, Ohyun;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • 제46권2호
    • /
    • pp.48-57
    • /
    • 2021
  • Background: In this study, the complexities of step-and-shoot intensity-modulated radiation therapy (IMRT) plans in magnetic resonance-guided radiation therapy systems were evaluated. Materials and Methods: Overall, 194 verification plans from the abdomen, prostate, and breast sites were collected using a 60Co-based ViewRay radiotherapy system (ViewRay Inc., Cleveland, OH, USA). Various plan complexity metrics (PCMs) were calculated for each verification plan, including the modulation complexity score (MCS), plan-averaged beam area (PA), plan-averaged beam irregularity, plan-averaged edge (PE), plan-averaged beam modulation, number of segments, average area among all segments (AA/Seg), and total beam-on time (TBT). The plan deliverability was quantified in terms of gamma passing rates (GPRs) with a 1 mm/2% criterion, and the Pearson correlation coefficients between GPRs and various PCMs were analyzed. Results and Discussion: For the abdomen, prostate, and breast groups, the average GPRs with the 1 mm/2% criterion were 77.8 ± 6.0%, 79.8 ± 4.9%, and 84.7 ± 7.3%; PCMs were 0.263, 0.271, and 0.386; PAs were 15.001, 18.779, and 35.683; PEs were 1.575, 1.444, and 1.028; AA/Segs were 15.37, 19.89, and 36.64; and TBTs were 18.86, 19.33, and 5.91 minutes, respectively. The various PCMs, i.e., MCS, PA, PE, AA/Seg, and TBT, showed statistically significant Pearson correlation coefficients of 0.416, 0.627, -0.541, 0.635, and -0.397, respectively, with GPRs. Conclusion: The area-related metrics exhibited strong correlations with GPRs. Moreover, the AA/Seg metric can be used to estimate the IMRT plan accuracy without beam delivery in the 60Co-based ViewRay radiotherapy system.

Deep Inspiration Breath Holding을 적용한 유방암 세기변조방사선치료 시 위치잡이오차 분석을 통한 선량 평가 (Dosimetric Comparison of Setup Errors in Intensity Modulated Radiation Therapy with Deep Inspiration Breath Holding in Breast Cancer Radiation Therapy)

  • 함일식;조평곤;정강교
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권2호
    • /
    • pp.137-143
    • /
    • 2019
  • The aim of this study was analyzed the setup error of breast cancer patients in intensity modulated radiation therapy(IMRT) with deep inspiration breath holding(DIBH) and was analyzed the dose distribution due to setup error. A total of 45 breast cancer cases were performed a retrospective clinical analysis of setup error. In addition, the re-treatment planning was carried by shifting the setup error from the isocenter at the treatment. Based on this, the dose distribution of PTV and OARs was compared and analyzed. The 3D error for small breast group and medium breast group and large breast group were 3.1 mm and 3.7 mm and 4.1 mm, respectively. The difference between the groups was statistically significant(P=0.003). DVH results showed HI, CI for the PTV difference between standard treatment plan and re-treatment plan of 14.4%, 4%. The difference in $D_5$ and $V_{20}$ of the ipsilateral lung was 5.6%, 13% respectively. The difference in $D_5$ and $V_5$ of the heart of right breast cancer patients was 6.8%, 8% respectively. The difference in $D_5$, $V_{20}$ of the heart of left breast cancer patients was 7.2%, 23.5% respectively. In this study, there was a significant association between breast size and significant setup error in breast cancer patients with DIBH. In addition, it was found that the dose distribution of the PTV and OARs varied according to the setup error.

Clinical performance of FractionLab in patient-specific quality assurance for intensity-modulated radiotherapy : a retrospective study

  • Oh, Se An;Kim, Sung Yeop;Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon
    • Journal of Yeungnam Medical Science
    • /
    • 제39권2호
    • /
    • pp.108-115
    • /
    • 2022
  • Background: This study was aimed at comparing and analyzing the results of FractionLab (Varian/Mobius Medical System) with those of portal dosimetry that uses an electronic portal imaging device. Portal dosimetry is extensively used for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Methods: The study includes 29 patients who underwent IMRT on a Novalis-Tx linear accelerator (Varian Medical System and Brain-LAB) between June 2019 and March 2021. We analyzed the multileaf collimator DynaLog files generated after portal dosimetry to evaluate the same condition using FractionLab. The results of the recently launched FractionLab at various gamma indices (0.1%/0.1 mm-1%/1 mm) are analyzed and compared with those of portal dosimetry (3%/3 mm). Results: The average gamma passing rates of portal dosimetry (3%/3 mm) and FractionLab are 98.1% (95.5%-100%) and 97.5% (92.3%-99.7%) at 0.6%/0.6 mm, respectively. The results of portal dosimetry (3%/3 mm) are statistically comparable with the QA results of FractionLab (0.6%/0.6 mm-0.9%/0.9 mm). Conclusion: This paper presents the clinical performance of FractionLab by the comparison of the QA results of FractionLab using portal dosimetry with various gamma indexes when performing patient-specific QA in IMRT treatment. Further, the appropriate gamma index when performing patient-specific QA with FractionLab is provided.

Evaluating the Effects of Dose Rate on Dynamic Intensity-Modulated Radiation Therapy Quality Assurance

  • Kim, Kwon Hee;Back, Tae Seong;Chung, Eun Ji;Suh, Tae Suk;Sung, Wonmo
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.116-121
    • /
    • 2021
  • Purpose: To investigate the effects of dose rate on intensity-modulated radiation therapy (IMRT) quality assurance (QA). Methods: We performed gamma tests using portal dose image prediction and log files of a multileaf collimator. Thirty treatment plans were randomly selected for the IMRT QA plan, and three verification plans for each treatment plan were generated with different dose rates (200, 400, and 600 monitor units [MU]/min). These verification plans were delivered to an electronic portal imager attached to a Varian medical linear accelerator, which recorded and compared with the planned dose. Root-mean-square (RMS) error values of the log files were also compared. Results: With an increase in dose rate, the 2%/2-mm gamma passing rate decreased from 90.9% to 85.5%, indicating that a higher dose rate was associated with lower radiation delivery accuracy. Accordingly, the average RMS error value increased from 0.0170 to 0.0381 cm as dose rate increased. In contrast, the radiation delivery time reduced from 3.83 to 1.49 minutes as the dose rate increased from 200 to 600 MU/min. Conclusions: Our results indicated that radiation delivery accuracy was lower at higher dose rates; however, the accuracy was still clinically acceptable at dose rates of up to 600 MU/min.

Influence of jaw tracking in intensity-modulated and volumetric-modulated arc radiotherapy for head and neck cancers: a dosimetric study

  • Mani, Karthick Raj;Upadhayay, Sagar;Das, K.J. Maria
    • Radiation Oncology Journal
    • /
    • 제35권1호
    • /
    • pp.90-100
    • /
    • 2017
  • Purpose: To Study the dosimetric advantage of the Jaw tracking technique in intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for Head and Neck Cancers. Materials and Methods: We retrospectively selected 10 previously treated head and neck cancer patients stage (T1/T2, N1, M0) in this study. All the patients were planned for IMRT and VMAT with simultaneous integrated boost technique. IMRT and VMAT plans were performed with jaw tracking (JT) and with static jaw (SJ) technique by keeping the same constraints and priorities for a particular patient. Target conformity, dose to the critical structures and low dose volumes were recorded and analyzed for IMRT and VMAT plans with and without JT for all the patients. Results: The conformity index average of all patients followed by standard deviation (${\bar{x}}{\pm}{\sigma}_{\bar{x}}$) of the JT-IMRT, SJ-IMRT, JT-VMAT, and SJ-VMAT were $1.72{\pm}0.56$, $1.67{\pm}0.57$, $1.83{\pm}0.65$, and $1.85{\pm}0.64$, and homogeneity index were $0.059{\pm}0.05$, $0.064{\pm}0.05$, $0.064{\pm}0.04$, and $0.064{\pm}0.05$. JT-IMRT shows significant mean reduction in right parotid and left parotid shows of 7.64% (p < 0.001) and 7.45% (p < 0.001) compare to SJ-IMRT. JT-IMRT plans also shows considerable dose reduction to thyroid, inferior constrictors, spinal cord and brainstem compared to the SJ-IMRT plans. Conclusion: Significant dose reductions were observed for critical structure in the JT-IMRT compared to SJ-IMRT technique. In JT-VMAT plans dose reduction to the critical structure were not significant compared to the SJ-IMRT due to relatively lesser monitor units.

양측성 유방암의 세기조절방사선치료(IMRT)와 부피적조절회전방사선치료(VMAT)의 비교연구 (A Dosimetric Comparision of IMRT and VMAT in Synchronous Bilateral Breast Cancer)

  • 김성진;윤선민;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.284-289
    • /
    • 2013
  • 양측성 유방암 환자를 대상으로 부피적 조절회전방사선치료와 세기조절방사선치료의 선량학적 결과를 비교하여 효율적인 치료방법을 제시함을 목적으로 한다. 5명의 환자를 대상으로 8개 빔의 세기조절방사선치료와 12개 빔의 세기조절방사선치료, 1회전 부피적 조절회전방사선치료 계획을 수립하였다. 그 결과를 DVH 분석을 통해 선량학적으로 비교분석하였다. PTV의 평균선량과 $D_{98}$을 보면 12-IMRT가 $51.04{\pm}0.57$ Gy (오른쪽), $50.80{\pm}1.07$ Gy (왼쪽), $42.94{\pm}16.16$ Gy (오른쪽), $42.56{\pm}2.09$ Gy (왼쪽)로 우수한 경향을 보인다. HI와 $CI_{90,95}$에서도 12-IMRT가 우수한 결과를 보였다. 중요장기에서는 세치료계획 모두 우수한 결과를 보였지만 12-IMRT에서 가장 낮은 선량을 보였다. 12-IMRT가 PTV와 OAR의 선량학적측면에서 우수한 결과를 보여주었다.

A Comparison between Portal Dosimetry and Mobius3D Results for Patient-Specific Quality Assurance in Radiotherapy

  • Kim, Sung Yeop;Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon;Oh, Se An
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.107-115
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the clinical quality assurance results of portal dosimetry using an electronic portal imaging device, a method that is extensively used for patient-specific quality assurance, and the newly released Mobius3D for intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Methods: This retrospective study includes data from 122 patients who underwent IMRT and VMAT on the Novalis Tx and VitalBeam linear accelerators between April and June 2020. We used a paired t-test to compare portal dosimetry using an electronic portal imaging device and the average gamma passing rates of MobiusFX using log files regenerated after patient treatment. Results: The average gamma passing rates of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm) were 99.43%±1.02% and 99.32%±1.87% in VitalBeam and 97.53%±3.34% and 96.45%±13.94% in Novalis Tx, respectively. Comparison of the gamma passing rate results of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm as per the manufacturer's manual) does not show any statistically significant difference. Conclusions: Log file-based patient-specific quality assurance, including independent dose calculation, can be appropriately used in clinical practice as a second-check dosimetry, and it is considered comparable with primary quality assurance such as portal dosimetry.

좌측 유방 방사선치료를 위한 역치료계획의 세기변조방사선치료와 다중빔조사영역치료기법 사이의 포괄적 선량측정 분석 (A Comprehensive Dosimetric Analysis of Inverse Planned Intensity Modulated Radiation Therapy and Multistatic Fields Technique for Left Breast Radiotherapy)

  • 문성권;윤선민
    • Radiation Oncology Journal
    • /
    • 제28권1호
    • /
    • pp.39-49
    • /
    • 2010
  • 목 적: 좌측 유방의 방사선치료에 있어, 3 빔 또는 5 빔을 이용한 세기변조방사선치료(intensity modulated radiation therapy, IMRT)와 다중빔조사영역 치료기법(multistatic fields techniques, MSF) 사이의 선량학적 차이를 분석하고자 하였다. 대상 및 방법: 개선된 선량 균일성을 만들 수 있는 가능성을 지닌 두 종류의 방사선치료 기술을 서로 비교 분석하였다. 첫째, 다중빔조사영역치료로 주조사야와 소조사야를 동시에 사용하여 치료하였다. 둘째, 고정된 다엽 조준기를 사용하는 IMRT로, 3 빔 또는 5 빔을 이용하였다. 유방보존술 후 방사선치료를 받은 16명의 초기 좌측 유방암 환자들을 대상으로 방사선치료계획들을 세운 다음, 이들을 선량학적 측면에서 비교 분석하였다. 결 과: $V_{95}$와 선량균일지수의 평균값은, 이 세 치료 사이에 통계학적으로 유의한 차이가 없었다. 방사선처방선량의 110% 이상을 받는 극심한 열점은 세 치료 모두에서 관찰되지 않았다. 동측 폐와 심장의 피폭 선량측정인자들에 대한 Tukey 검정에서, 세기변조방사선치료가 다중빔조사영역치료에 비해 저선량 영역의 피폭 선량을 유의하게 증가시킨 반면, 오히려 고선량 영역에서는 다중빔조사영역치료가 방사선 피폭을 약간 증가시켰다. 결 론: 선량 균일성 개선을 위해, 통상적인 쐐기기법 대신, 세기변조방사선치료보다 쉽게 계획되고 실시 될 수 있는 다중빔조사영역치료의 적용은 초기 좌측 유방암의 방사선치료 기술로 적합하다고 생각한다.