• Title/Summary/Keyword: Integration power system

Search Result 536, Processing Time 0.027 seconds

A Methodology for Reliability and Economic Analysis of Wind Energy Embedded Electric Power System (풍력을 포함하는 전력 시스템의 신뢰성과 경제성 해석 방법)

  • Jain, Amit;Min, Joon-Ki;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1316-1318
    • /
    • 2002
  • A methodology for reliability and economic analysis of wind embedded electric power system is presented in this paper. This is done by evaluating the reliability index, loss of load expectation (LOLE), for the power system with and without integration of wind system in the overall electric power system. Economic analysis of the wind energy embedded electric system is done in terms of conventional fuel saving assessment due to the use of wind power generation units.

  • PDF

Development of IEC 61850 based Integration Engineering Tool for Intelligent Electronic Device (IEC 61850 기반의 IED 통합 엔지니어링 툴 개발)

  • Han, Jeong-Yeol;Ahn, Yong-Ho;Jang, Byung-Tae;Song, In-Jun;Kim, Yong-Hak
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.101-108
    • /
    • 2010
  • In order to construct the IEC 61850 based substation automation system, the IED integration engineering tool is necessary to cope with the substation automation by full digital devices in the real power system. Compared the configuration tools provided IED vendors which are able to support the operation and communication analysis among IEDs, the XML based IED integration engineering tool can build, edit and save the ICD, SCL and CID files. Particularly, the IED integration engineering tool is possible to apply the IEC 61850 based IEDs to engineering the systems and also provides the reliability and efficiency of the system to the utilities and manufacturers.

Frequency Stabilization Method for Grid Integration of Large-scale Centralized Wind Farms via VSC-HVDC Technology

  • Peng, Yanjian;Li, Yong;Liu, Fang;Xu, Zhiwei;Cao, Yijia
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.547-557
    • /
    • 2018
  • This work proposes a control method of frequency stabilization for grid integration of large-scale wind farms via the voltage source converter-based high-voltage direct current (VSC-HVDC) technology. First, the topology of grid integration of a large-scale wind farm via the VSC-HVDC link is provided, and simple control strategies for wind turbines, wind farm side VSC (WFVSC), and grid side VSC are presented. Second, a mathematical model between the phase angle of WFVSC and the frequency of the wind farm is established. The control principle of the large-scale wind power integrated system is analyzed in theory in accordance with the mathematical model. Third, frequency and AC voltage controllers of WFVSC are designed based on the mathematical model of the relationships between the phase angle of WFVSC and the frequency of the wind farm, and between the modulation index of WFVSC and the voltage of the wind farm. Corresponding controller structures are established by deriving a transfer function, and an optimization method for selecting the parameters of the frequency controller is presented. Finally, a case study is performed under different operating conditions by using the DIgSILENT/PowerFactory software. Results show that the proposed control method has good performance in the frequency stabilization of the large-scale wind power integrated system via the VSC-HVDC technology.

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Kim, Eung-Sik;Kim, Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2433-2440
    • /
    • 2009
  • Whole system and network for supply of electric power and electricity safety are essential element. Electricity safety technology need rating for product and research about certification as product development that is done electric power u-IT cotton flannel mixed with development of u-IT, u-City base technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power u-IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication module about function of product for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in electric leakage, high voltage, Arc, fire detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

Research of an On-Line Measurement Method for High-power IGBT Collector Current

  • Hu, Liangdeng;Sun, Chi;Zhao, Zhihua
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.362-373
    • /
    • 2016
  • The on-line measurement of high-power IGBT collector current is important for the hierarchical control and short-circuit and overcurrent protection of its driver and the sensorless control of the converter. The conventional on-line measurement methods for IGBT collector current are not suitable for engineering measurement due to their large-size, high-cost, low-efficiency sensors, current transformers or dividers, etc. Based on the gate driver, this paper has proposed a current measuring circuit for IGBT collector current. The circuit is used to conduct non-intervention on-line measurement of IGBT collector current by detecting the voltage drop of the IGBT power emitter and the auxiliary emitter terminals. A theoretical analysis verifies the feasibility of this circuit. The circuit adopts an operational amplifier for impedance isolation to prevent the measuring circuit from affecting the dynamic performance of the IGBT. Due to using the scheme for integration first and amplification afterwards, the difficult problem of achieving high accuracy in the transient-state and on-state measurement of the voltage between the terminals of IGBT power emitter and the auxiliary emitter (uEe) has been solved. This is impossible for a conventional detector. On this basis, the adoption of a two-stage operational amplifier can better meet the requirements of high bandwidth measurement under the conditions of a small signal with a large gain. Finally, various experiments have been carried out under the conditions of several typical loads (resistance-inductance load, resistance load and inductance load), different IGBT junction temperatures, soft short-circuits and hard short-circuits for the on-line measurement of IGBT collector current. This is aided by the capacitor voltage which is the integration result of the voltage uEe. The results show that the proposed method of measuring IGBT collector current is feasible and effective.

Developing Intelligent Control Modules with LonTalk Protocol for Intelligent Building System & Home Automation

  • Hong, Won-Pyo;Kim, Dong-Hwa;Lee, Sung-Hak
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.355-361
    • /
    • 2002
  • There are many economic and operational reasons to integrate fire alarm signaling system with other building automation system. Integration of this requires open network with for the standard communication protocol and careful design practices. The important point for this is also the development of intelligent control modules for replacing the conventional zone adapter in fire system. Therefore, this paper proposes an new conceptual design of the open distributed fire alarm signaling system for the integration of BAS, a new intelligent control modules with LonTalk protocol and a new control modules for power line communication. Newly proposed additions to LonWorks network make it very well suited for integrating fire systems with other building automation sub-systems and another BAS with low cost. Additionally, it is very important that best design practices, test procedures and building codes need to be modernized to accommodate integrated building systems.

  • PDF

Development of 1kW Class PEFC System for Residential Applications (1kW급 가정용 연료전지 시스템 실증 연구)

  • Choi, Dong-Min;Shin, Bum-Su;Park, Yon-Goo;Ham, Mi-Sook;Shim, Jae-Hwi
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.174-176
    • /
    • 2008
  • HYOSUNG manufactured and tested 1kw class PEFC systems to generate electrical and thermal energy for each residential usage. In particular, HYOSUNG developed Power conditioning system that performs about 91% electrical conversion ratio specified in 1kW class PEFC systems. Prior to system integration, we tested each performances of components to derive control issues from it. In addition, we have been developing the adequate simulator to describe and predict system performance. In this paper, we verified HYOSUNG's 1kW class PEFC systems are valid for residential energy sureces by testing the characteristics of systems and performances of main component.

  • PDF

A Study About Distribution Automation System Based on CIM (CIM 기반의 Distribution Automation System에 관한 연구)

  • Lee, Hee-Joo;Seo, Jeong-Il;Han, Ju-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.913-920
    • /
    • 2011
  • Distribution systems for operating the various systems should be operated organically. Distribution systems for organic operations extend the functionality of the system and system integration for the extension is doing. However, in systems integration for each unique non-standard definition of linkage and exchange systems are used. Non-standard definition of a unique linkage and exchange systems in the maintenance and expansion will result in many negative results. To solve these problems, the system and the exchange of information about the links between systems should define standards. IEC (International Electrotechnical Commission) power to solve these problems in the field of the Common Information Model (Common Information Model, CIM) standard (IEC61970, IEC61968) is defined as the transmission and distribution system integration and standardization for the exchange of information. In this paper, standardized system for building CIM-based distribution automation system should describe the process of building. In addition, the process of establishing a common information model needed (CIM) defined and associated services for a defined set of models is proposed in the standardization process.

A Dynamic-explicit Finite Element Analysis for Hydro-forming Process (Hydro-forming 공정을 위한 동적-외연적 유한요소해석)

  • Jung, D.W.;Hwang, J.S.
    • Journal of Power System Engineering
    • /
    • v.8 no.3
    • /
    • pp.23-29
    • /
    • 2004
  • In this paper, a finite element formulation using dynamic-explicit time integration scheme is used for numerical analysis of Hydro-forming processes. The lumping scheme is employed for the diagonal mass matrix and dynamic explicit formulation. Hydro-forming process for auto-body panel forming is analyzed by using dynamic-explicit finite element method. Further, the simulated results of the Hydro-forming processes are shown and discussed. Its application is being increased especially in the automotive industrial area for the cost reduction, weight saving, and improvement of strength.

  • PDF

A Study on Development of an Integration Methodology for Design Guideline of Advanced Information Display (개량형 정보표시 화면설계 지침의 일원화 방법론 개발에 관한 연구)

  • Jeong, Seong-Hae;Cha, U-Chang
    • Journal of the Ergonomics Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.13-24
    • /
    • 2004
  • Human error has brought about accidents more than 50% in system of a large size and complicated expecially in nuclear power plants(NPPs). The technology of Man Machine Interface(MMI) has been changed to the digitalized controls employing computer-based technology. According to this trend. the human factors guidelines are becoming main issue for reliable supports to digitalized information displays. However. the existing human factors guidelines is not enough for advanced information display on NPPs. The purpose of this research is to develop the reliable design and evaluation guidelines for advanced information display in main control room (MCR) of NPPs. In this study. the various general human factors guidelines concerning information display on CRT are integrated on data base management system. unified based on the integration rules. and applied in computer based procedures. The use of the integrated guidelines are expected to evaluate the existing information display on MCR in NPPs from the human factors point of view.