• Title/Summary/Keyword: Integrated power control unit

Search Result 74, Processing Time 0.024 seconds

Establishment and Application of a Femtosecond-laser Two-photon-polymerization Additive-manufacturing System

  • Li, Shanggeng;Zhang, Shuai;Xie, Mengmeng;Li, Jing;Li, Ning;Yin, Qiang;He, Zhibing;Zhang, Lin
    • Current Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.381-391
    • /
    • 2022
  • Two-photon-polymerization additive-manufacturing systems feature high resolution and precision. However, there are few reports on specific methods and possible problems concerning the use of small lasers to independently build such platforms. In this paper, a femtosecond-laser two-photon-polymerization additive-manufacturing system containing an optical unit, control unit, monitoring unit, and testing unit is built using a miniature femtosecond laser, with a detailed building process and corresponding control software that is developed independently. This system has integrated functions of light-spot detection, interface searching, micro-/nanomanufacturing, and performance testing. In addition, possible problems in the processes of platform establishment, resin preparation, and actual polymerization for two-photon-polymerization additive manufacturing are explained specifically, and the causes of these problems analyzed. Moreover, the impacts of different power levels and scanning speeds on the degree of polymerization are compared, and the influence of the magnification of the object lens on the linewidth is analyzed in detail. A qualitative analysis model is established, and the concepts of the threshold broadening and focus narrowing effects are proposed, with their influences and cooperative relation discussed. Besides, a linear structure with micrometer accuracy is manufactured at the millimeter scale.

Fault Management Design Verification Test for Electrical Power Subsystem and Attitude and Orbit Control Subsystem of Low Earth Orbit Satellite (저궤도위성의 전력계 및 자세제어계 고장 관리 설계 검증시험)

  • Lee, Sang-Rok;Jeon, Hyeon-Jin;Jeon, Moon-Jin;Lim, Seong-Bin
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.14-23
    • /
    • 2013
  • Fault management design of the satellite describes preparations for failures which can occur during operational phase. Fault management design contains detection and isolation function of anomaly, and also it contains function to maintain the satellite in safe condition until the ground station finds out a cause of failure and takes a countermeasure. Unlike normal operation, safing operation is automatically performed by Power Control and Distribution Unit and Integrated Bus Management Unit which loads Flight Software without intervention of ground station. Since fault management operation is automatical, fault management logic and functionality of relevant hardware should be thoroughly checked during ground test phase, and error which is similar to actual should be carefully applied without damage. Verification test for fault management design is conducted for various subsystems of satellite. In this paper, we show the design process of fault management design verification test for Electrical Power Subsystem and Attitude and Orbit Control Subsystem of Low Earth Orbit satellite flight model and the test results.

Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels (채광시스템과 인공조명설비의 통합기술 및 성능평가연구)

  • Kim, G.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

Development of the Oil Consumption Rate Test Method and Measurement Data Analysis for an Automatic Transmission System (자동변속기 오일 소요유량 시험법개발 및 측정데이터 분석)

  • Jeong, H.S.;Oh, S.H.;Yi, J.S.;Lim, J.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.1
    • /
    • pp.10-16
    • /
    • 2009
  • Automatic power transmission systems consisted of a torque converter and several planetary gear sets, clutches and brakes are controlled by a hydraulic shift control circuit and an electronic transmission control unit. The hydraulic circuit serves for the operation of the torque converter and lubrication oil supply of the transmission system as well as for the actuation of clutches for the automatic gear shift. The complicated hydraulic control circuit constructed by many spools, solenoids, orifices and flow passages are integrated into one small valve block and it is powered by one hydraulic pump. In this paper, a test equipment was developed to measure the oil consumption of each component at various wide operating conditions. Test data about 730 sets acquired from five test items are analyzed and discussed on the oil capacity of the circuit.

  • PDF

A Study on the Design of the Bay Controller for Generator Protection and Control (발전기 보호제어를 위한 Bay Controller 설계에 관한 연구)

  • Jang, Nak-Won;Woo, Chun-Hee;Lee, Sung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.46-55
    • /
    • 2008
  • In this paper, we designed the bay control unit that is based on the microprocessors and integrates with the new technology of electrical, electronic, and mechanical fields. Nowadays the customers have required much more integrated multi-protection relay, monitoring, control devices and power management for better and easier maintenance, performance, electrical system analysis and communication according to new trend of switchboard This bay controller supplies those requirements of customers with easy handling and operation. This bay controller provides a graphic display with rear-lit liquid crystal LCD and push buttons as kinds of HMI(Human Machine Interface). This bay controller provides the parameter setting program, control setting program, various editors and fault recording and analysis program on Windows/95/98/NT/2000/XP for HMI. In addition, this bay controller can be set manually and this manual setting function helps user to interface easily.

Free Control Stability Analysis of Sports Utility Vehicle-EPS (Sports Utility Vehicle-EPS의 자유제어 안정성 해석)

  • 장봉춘;권대규
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.162-167
    • /
    • 2004
  • In this research the Co-simulation technique for an electric power steering system with MATLAB/SIMULINK and a full vehicle model with ADAMS has been developed. The dynamic responses of vehicle chassis and steering system are evaluated. Then, a full vehicle model interacted with EPS control is concurrently simulated with an impulsive steering wheel torque input to analyze the stability of 'free control' or hands free motion for Sports Utility Vehicle. This integrated method allows engineers to reduce the prototype testing cost and to shorten the developing period.

A Low-Power Single Chip Li-Ion Battery Protection IC

  • Lee, Seunghyeong;Jeong, Yongjae;Song, Yungwi;Kim, Jongsun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.4
    • /
    • pp.445-453
    • /
    • 2015
  • A fully integrated cost-effective and low-power single chip Lithium-Ion (Li-Ion) battery protection IC (BPIC) for portable devices is presented. The control unit of the battery protection system and the MOSFET switches are integrated in a single package to protect the battery from over-charge, over-discharge, and over-current. The proposed BPIC enters into low-power standby mode when the battery becomes over-discharged. A new auto release function (ARF) is adopted to release the BPIC from standby mode and safely return it to normal operation mode. A new delay shorten mode (DSM) is also proposed to reduce the test time without increasing pin counts. The BPIC implemented in a $0.18-{\mu}m$ CMOS process occupies an area of $750{\mu}m{\times}610{\mu}m$. With DSM enabled, the measured test time is dramatically reduced from 56.82 s to 0.15 s. The BPIC chip consumes $3{\mu}A$ under normal operating conditions and $0.45{\mu}A$ under standby mode.

Simulation Analysis and Development of Matlab/Simulink Model for Stand-alone Operation of Emergency Diesel Synchronous Generator-based Hybrid Energy System (비상용 디젤동기발전시스템기반 독립운전 하이브리드에너지시스템 모델 설정 및 시뮬레이션 분석에 관한 연구)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.70-79
    • /
    • 2015
  • In this paper, enhanced stand-alone operation and development of Matlab/Simulink model of emergency diesel based hybrid energy system is presented. Simulations based on the remote community or islands were performed for PV-diesel-battery hybrid system. Modeling of PV-diesel-battery integrated system is done to perform under the solar radiation and load conditions on Matlab/Simulink platform. The models of diesel generator unit, battery energy storage system, PV and frequency-power control are developed and simulation studies have been carried out under various conditions using Matlab/Simulink and SimPowerSystem. It is demonstrated that the proposed system can provide reliable and good quality power to the customers in diesel synchronous generator-based hybrid energy systems.

A Study on the Heat Balance of Cooling System for Armored Vehicles (밀폐형 차량 냉각시스템에 대한 열평형 연구)

  • Kim, S.K.;Ahn, S.H.;Nam, K.W.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.70-75
    • /
    • 2007
  • Heat transfer coefficient and fin efficiency of a heat exchanger dispersed in the microelement of control volume were predicted with various flow patterns, conditions and material properties. A computational program was developed by using the method of efficiency-NTU(Number of transfer unit). The modelling was applied to heat exchangers, also was integrated in power pack cooling system in an armored vehicle. The compatibility and the generality were proved by comparing the prediction values with the test results. The developed program may be useful for the design of the cooling system in an armored vehicle.

  • PDF

Fault Tolerant Design of Universal Soft Controller for Advanced Power Reactor (신형원전(APR+)을 위한 범용소프트제어기의 내고장성 설계)

  • Ye, Song-Hae;Lyou, Joon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.279-286
    • /
    • 2012
  • Recently, design of Universal Soft Controller(USC) has been applied to the advanced control room for nuclear power plant. USC is software-based manual control means to control safety components as well as non-safety components in the highly-integrated control room. Therefore, design feature of USC is essential for the implementation of a single workstation in the advanced control room. The traditional control room is replaced by computer-driven consolidated operator interfaces. Considering our design has further reduced the probability of USC spurious signals by requiring two distinct operator control actions to generate any control signal. The reality of USC does not increase the probability of reactor trip because the probability of spurious USC signal is negligible. Universal Soft Control represents a significant evolution in nuclear I&C/HSI System. USC integrates the indicators and controls from multiple divisions into a single integrated visual display unit(VDU) based HSI(Human System Interface). In order to prevent adverse influence on safety function performance from USC failure, ESFAS signals are applied to safety components or functions. In addition, safety manual switches have priority over USC's signals. Therefore, spurious USC signals can be momentarily blocked by selecting a soft control command from the safety VDU.