• 제목/요약/키워드: Integrated module

검색결과 985건 처리시간 0.031초

주택 지붕일체형 PV시스템 후면환기에 따른 발전성능 변화 실험연구 (Experimental Study on the Combined Effect of Power and Heat according to the Ventilation of Back Side in Roof Integrated PV System)

  • 윤종호;한규복;안영섭
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.169-174
    • /
    • 2007
  • Building integrated photovoltaic(BIPV) system operates as a multi-functional building construction material. They not only produce electricity, but also are building integral components such as facade, roof, window and shading device. As PV modules function like building envelope in BIPV, combined thermal and PV performance should be simultaneously evaluated. This study is to establish basic Information for designing effective BIPV by discovering relations between temperature and generation capability through experiment when the PV module is used as roof material for houses. To do so, we established 3kW full scale mock-up model with real size house and attached an PV array by cutting in half. This is to assess temperature influence depending on whether there is a ventilation on the rear side of PV module or not.

Zynq를 이용한 비전 및 모션 컨트롤러 통합모듈 구현 (Implementation of Integration Module of Vision and Motion Controller using Zynq)

  • 문용선;노상현;이영필
    • 한국전자통신학회논문지
    • /
    • 제8권1호
    • /
    • pp.159-164
    • /
    • 2013
  • 최근 자동화 시스템에 있어 중요한 요소인 비전과 모션 컨트롤러를 통합한 솔루션이 많이 개발되고 있다. 다만 이러한 솔루션은 비전 처리와 모션 컨트롤을 네트워크로 통합하거나 하나의 모듈에 투 칩 솔루션으로 구성된 경우가 많다. 본 연구에서는 최근에 개발된 확장형 프로세싱 플랫폼인 Zynq-7000을 이용한 비전 및 모션 제어기를 통합한 원 칩 솔루션을 구현하였다. 또한 모션 컨트롤은 제어의 실시간이 보장되면서 대량의 데이터를 처리할 수 있는 개방형 표준 이더넷 호환성을 가지고 있는 산업용 이더넷 프로토콜인 EtherCAT을 적용하였다.

단열 복층유리 PV의 커튼 월 적용 가능성에 관한 실험적 연구 (The Experimental Study on the Application of the Insulated Glass PV Module in the Curtain Wall)

  • 오민석;김회서
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.63-69
    • /
    • 2006
  • In order to positively cope with the international environmental regulations like UNFCCC (UN Framework Convention on Climate Change) and to overcome energy crisis Korea, who depends on import for more than 97% of required energy, needs to continuously proceed to development, spread and expansion of alternativeenergy and then, to cultivate the capacity to keep the balance of demand and supply of energy by itself. In this aspect, the technology of BIPV (Building Integrated Photovoltaic) is the field that the world is most interested in. However, at present, this technology is centered on increasing the efficiency of the module itself so it has lots of problems to be applied to buildings. Application of the integrated PV system in building external curtain wall can obtain much more generation of electric power than in roof-types whose area for installation is restricted, so it is excellent in terms of its possibility of application. Therefore, this paper intends to advance its practical use by proposing how to get integrated PV system which can be applied to building external curtain wall, and how to apply it.

A Fully-Integrated Penta-Band Tx Reconfigurable Power Amplifier with SOI CMOS Switches for Mobile Handset Applications

  • Kim, Unha;Kang, Sungyoon;Kim, Junghyun;Kwon, Youngwoo
    • ETRI Journal
    • /
    • 제36권2호
    • /
    • pp.214-223
    • /
    • 2014
  • A fully-integrated penta-band reconfigurable power amplifier (PA) is developed for handset Tx applications. The output structure of the proposed PA is composed of the fixed output matching network, power and frequency reconfigurable networks, and post-PA distribution switches. In this work, a new reconfiguration technique is proposed for a specific band requiring power and frequency reconfiguration simultaneously. The design parameters for the proposed reconfiguration are newly derived and applied to the PA. To reduce the module size, the switches of reconfigurable output networks and post-PA switches are integrated into a single IC using a $0.18{\mu}m$ silicon-on-insulator CMOS process, and a compact size of $5mm{\times}5mm$ is thus achieved. The fabricated W-CDMA PA module shows adjacent channel leakage ratios better than -39 dBc up to the rated linear power and power-added efficiencies of higher than around 38% at the maximum linear output power over all the bands. Efficiency degradation is limited to 2.5% to 3% compared to the single-band reference PA.

가스터빈 동기기 통합형 기동 및 여자시스템 개발 (Development of Integrated Start-up and Excitation System for Gas Turbine Synchronous Generator)

  • 류호선;차한주
    • 전기학회논문지P
    • /
    • 제63권3호
    • /
    • pp.183-188
    • /
    • 2014
  • Power conversion systems used in large gas turbine power plant can be divided into two main part. Because of the initial start-up characteristic of the gas turbine combustor, the gas turbine must be accelerated by starting device(LCI : Load Commutated Inverter) up to 10%~20% of rated speed to ignite it. In addition, the ECS(Excitation Control system) is used to control the rotor field current and reactive power in grid-connected synchronous generator. These two large power conversion systems are located in the same space(container) because of coordination control. Recently, many manufactures develop high speed controller based on function block available in the LCI and ECS with the newest power semiconductor. We also developed high speed controller based on function block to be using these two system and it meets the international standard IEC61131 as using real-time OS(VxWorks) and ISaGRAF. In order to install easily these systems at power plant, main controller, special module and IO module are used with high speed communication line other than electric wire line. Before initial product is installed on the site, prototype is produced and tests are conducted for it. The performance results of Integrated controller and application program(SFC, ECS) were described in this paper. The test results will be considered as the important resources for the application in future.

Cold facade형 BIPV시스템의 발전성능 분석 (Analysis of Performance of Building Integrated PV System of Cold Facade type)

  • 김현일;강기환;박경은;유권종;서승직
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.275-280
    • /
    • 2008
  • Photovoltaic(PV) permit the on-site production of electricity without concern for fuel supply or environmental adverse effects. The electrical power is produced without noise and little depletion of resources. So BIPV(Building-Integrated Photovoltaic) system have been increased around the world. Hereby the relative installation costs of the system will be relatively low compared to traditional installations of PV in high-rise buildings. This paper examined possibility of BIPV system of cold facade type and analyzed of performance of BIPV system of cold facade type. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. If this BIPV system of 1.1kW is possible the natural ventilation in the summer case, the temperature of PV module decrease and then the efficiency of PV system increase generally. By the results, the annual averaged PR of BIPV system of cold facade type is about 73.1%.

  • PDF

Ultra-Wide-Band (UWB) Band-Pass-Filter for Wireless Applications from Silicon Integrated Passive Device (IPD) Technology

  • Lee, Yong-Taek;Liu, Kai;Frye, Robert;Kim, Hyun-Tai;Kim, Gwang;Aho, Billy
    • 마이크로전자및패키징학회지
    • /
    • 제18권1호
    • /
    • pp.41-47
    • /
    • 2011
  • Currently, there is widespread adoption of silicon-based technologies for the implementation of radio frequency (RF) integrated passive devices (IPDs) because of their low-cost, small footprint and high performance. Also, the need for high speed data transmission and reception coupled with the ever increasing demand for mobility in consumer devices has generated a great interest in low cost devices with smaller form-factors. The UWB BPF makes use of lumped IPD technology on a silicon substrate CSMP (Chip Scale Module Package). In this paper, this filter shows 2.0 dB insertion loss and 15 dB return loss from 7.0 GHz to 9.0 GHz. To the best of our knowledge, the UWB band-pass-filter developed in this paper has the smallest size ($1.4\;mm{\times}1.2\;mm{\times}0.40\;mm$) while achieving equivalent electrical performance.

고장물리 기반 자동차 서스펜션 모듈 내구설계 (PoF based Fatigue Durability Analysis of Automobile Suspension Module)

  • 한승호;이재경;이태희;장광섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1320-1325
    • /
    • 2008
  • In the manufacture of automobile suspension modules at a company as parts supplier, the design process includes the detail design and the design modification via structural and fatigue durability analyses considering PoF(physics of failure) of their weldments that are repeated more than four times sequentially. The approval of the design and the release of final drawings follows. For the suspension modules, e.g. control arms and cross member, the man-hours per worker required in the process outlined above can reach as high as 1,414hours. Application of the developed integrated design system can reduce the man-hours of 1,004. In comparison with the conventional design process, this integrated design system reduces the required time by about 40%. If expense is taken into account, a savings of approximately $192,000 is estimated, assuming the design process accounts for 1.5% of total sales for the parts supplier

  • PDF

자동 연마 시스템의 사용자 지향형 통합 프로그램 및 자동 교시 시스템 개발 (Development of User Friendly Integrated Program and Teaching System for Automatic Polishing Robot System)

  • 고석조;이민철;이만형;안중환;김성한;이돈진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.123-123
    • /
    • 2000
  • Polishing a die that has free-form surfaces is a time-consuming and tedious job, and requires a considerable amount of high-precision skill. In order to reduce the polishing time and cope with the shortage of skilled workers, a user-friendly automatic polishing system was developed in this research. The polishing system with five degrees of freedom is able to keep the polishing tool normal to the die surface. The polishing system is controlled by a PC-NC controller. And, to easily onerate the developed polishing system, this stud)r developed a integrated program in the Windows environment. This program consists of 4 modules: polishing module, a graphic simulator, a polishing data generation module, and a teaching. Also, the automatic teaching system was developed to easily obtain a teaching data. The developed teaching system consists of a three dimensional joystick and a proximity sensor. In order to evaluate stability of the driving program and the leaching system, polishing experiments of the die of saddle shape were carried out.

  • PDF

Architectural Design of Terminal Operating System for a Container Terminal Based on a New Concept

  • Singgih, Ivan Kristianto;Jin, Xuefeng;Hong, Soondo;Kim, Kap Hwan
    • Industrial Engineering and Management Systems
    • /
    • 제15권3호
    • /
    • pp.278-288
    • /
    • 2016
  • Automation ensures accurate and well-organized container transportation in container terminals. This paper addresses operational issues such as equipment scheduling and the coordination between various pieces of equipment in a rail-based automated container terminal. Containers are relayed using multiple types of equipment from road trucks to a vessel and vice versa. Therefore, handshaking is required during a container transfer between different pieces of equipment. Synchronization between the schedules of all the equipment is important to reduce equipment waiting times and the time required for transporting containers, which results in a short turnaround time for a vessel. This paper proposes an integrated control system with the objective of synchronizing the operations of different types of equipment, provides a list of decisions to be made by the control module of each type of equipment, and shows all the required information transfers between control modules. A scheme for the integrated scheduling of multiple types of equipment is proposed. The decisions made by each control module in a real-time fashion are listed with detailed explanations, and the information transfer between managers in a real-time situation at the proposed terminal is described.