• Title/Summary/Keyword: Integrated Storage Operation

Search Result 87, Processing Time 0.035 seconds

On Improving the Productivity of Busan Container Terminal (부산 컨테이너 부두의 효율적인 운영방안에 관하여)

  • 이병국;이철영
    • Journal of the Korean Institute of Navigation
    • /
    • v.11 no.1
    • /
    • pp.39-65
    • /
    • 1987
  • Since the middle of 1950's, containerization has been rapidly spread over the world in virtue of great merits providing to interensts, and the fundamental changes in port management and prot operations are resulted. As the container terminal is a complex system which is consisted of various subsystems, the treatment for improving the productivity is required in a comprehensive fashion, both in each of its parts and as an integrated system. This paper aims to make an intensive analysis of the Busan Container Terminal system, especially focusing on its subsystems such as ship operation system, storage system and transfer system. First of all, the intrinsic capacity of various subsystems is calculated and it is checked whether the current operation is being performed effectively through the formal analysis. Secondly, the suggestion is presented to improve the operation by considering the throughput that the port of Busan will have to accept in the near future. The results are as follows; 1) As the inefficiency is due to the imbalance between various subsystems at Busan terminal, transfer equipment level must be up to 31% for straddle carrier and 67% transfer crane above all. 2) The yard capacity must be increased by reducing the free dwell time of containers in order to accept the traffic volume smoothly in the near future. 3) The better way to reduce the port congestion is to change berthing rule from the FIFP to the Pre-allocated system by considering the ship arrival pattern.

  • PDF

A Study on the Proper Inspection Cycle Plan Through Reliability Analysis of One-Shot System (One-Shot System의 신뢰도 분석을 통한 적정 점검주기 방안 연구)

  • June-Young Lim;Hyeonju Seol
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.1
    • /
    • pp.48-54
    • /
    • 2023
  • Guided missiles are a one-shot system that finishes their purpose after being used once, and due to the long-term storage until launch, the storage reliability is calculated during development, and performance is maintained through periodic inspections until the life cycle arrives. However, the reliability standards applied in the development of guided missiles were established by analyzing data accumulated by the United States during long-term operation in the country, and since they are different from our environment, the 00 guided missiles that have been deployed in the armed forces for more than 10 years under the premise that there is a difference from actual reliability. As a result of verifying the appropriateness of the current inspection cycle by analyzing the actual reliability of the missile, the necessity of changing the inspection period was derived because it was higher than the predicted reliability. It is proposed to build and utilize a lifespan management system that can systematically collect all data such as shooting and maintenance results by classification, and to establish a reliable reliability standard based on the accumulated data.

Design and Implementation of PC-based hospital-integrated PACS in Seoul National University Hospital

  • Kim, Jong-Hyo;Yeon, Kyoung-Mo;Han, Man-Chung;Lee, Dong-Hyuk;Jo, Han-Ik
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.478-483
    • /
    • 1997
  • The SNUH has started a PACS project with three main goals : to develop a fully hospital-integrated PACS, to develop a cost effective PACS using open systems architecture, and to extend PACS' role to the advanced application such as image guided surgery, multi-media assisted education and research. In order to achieve these goals, we have designed a PACS architecture which takes advantages of client-server computing, high speed communication network, computing power of up-to-date high-end PC, and advanced image compression method. We have installed ATM based communication network in radiology department and in-patient wards, and implemented DICOM compliant acquisition modules, image storage and management servers, and high resolution display workstations based on high-end PC and Microsoft Windows 95 and Windows NT operating systems. The SNUH PACS is in partial scale operation now, and will be expanded to full scale by the end of 1998.

  • PDF

Sensitivity Enhancement for Thermophysical Properties Measurements via the Vacuum Operation of Heater-integrated Fluidic Resonators (가열 전극 통합 채널 공진기의 진공 환경 구동에 의한 열물성 측정의 민감도 향상)

  • Juhee Ko;Jungchul Lee
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.39-43
    • /
    • 2023
  • Microscale thermophysical property measurements of liquids have been developed considering the increasing interest in the thermal management of cooling systems and energy storage/transportation systems. To accurately predict the heat transfer performance, information on the thermal conductivity, heat capacity, and density is required. However, a simultaneous analysis of the thermophysical properties of small-volume liquids has rarely been considered. Recently, we proposed a new methodology to simultaneously analyze the aforementioned three intrinsic properties using heater-integrated fluidic resonators (HFRs) in an atmospheric pressure environment comprising a microchannel, resistive heater/thermometer, and mechanical resonator. Typically, the thermal conductivity and volumetric heat capacity are measured based on a temperature response resulting from heating using a resistive thermometer, and the specific heat capacity can be obtained from the volumetric heat capacity by using a resonance densitometer. In this study, we analyze methods to improve the thermophysical property measurement performance using HFRs, focusing on the effect of the ambience around the sensor. The analytical method is validated using a numerical analysis, whose results agree well with preliminary experimental results. In a vacuum environment, the thermal conductivity measurement performance is enhanced, except for the thermal conductivity range of most gases, and the sensitivity of the specific heat capacity measurement is enhanced owing to an increase in the time constant.

Optimal Design of Process-Inventory Network Considering Exchange Rates and Taxes in Multinational Corporations (다국적 기업에서 환율과 세금을 고려한 공정-저장조 망구조의 최적설계)

  • Yi, Gyeong-Beom;Suh, Kuen-Hack
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.9
    • /
    • pp.932-940
    • /
    • 2011
  • This paper presents an integrated analysis of supply chain and financing decisions of multi-national corporation. We construct a model in which multiple currency storage units are installed to manage the currency flows associated with multi-national supply chain activities such as raw material procurement, process operation, inventory control, transportation and finished product sales. Core contribution of this study is to quantitatively investigate the influence of macroscopic economic factors such as exchange rates and taxes on operational decisions. The supply chain is modeled by the Process-Storage Network with recycle streams. The objective function of the optimization is minimizing the opportunity costs of annualized capital investments and currency/material inventories minus the benefit to stockholders interpreted by home currency. The major constraints of the optimization are that the material and currency storage units must not be depleted. A production and inventory analysis formulation, the periodic square wave (PSW) model, provides useful expressions for the upper/lower bounds and average levels of the currency and material inventory holdups. The expressions for the Kuhn-Tucker conditions of the optimization problem are reduced to a subproblem and analytical lot sizing equations. The procurement, production, transportation and financial transaction lot sizes can be determined by analytical expressions after the average flow rates are already known. We show that, when corporate income tax is taken into consideration, the optimal production lot and storage sizes are smaller than is the case when such factors are not considered typically by 20 %.

A Study on the Thermal Prediction Model cf the Heat Storage Tank for the Optimal Use of Renewable Energy (신재생 에너지 최적 활용을 위한 축열조 온도 예측 모델 연구)

  • HanByeol Oh;KyeongMin Jang;JeeYoung Oh;MyeongBae Lee;JangWoo Park;YongYun Cho;ChangSun Shin
    • Smart Media Journal
    • /
    • v.12 no.10
    • /
    • pp.63-70
    • /
    • 2023
  • Recently, energy consumption for heating costs, which is 35% of smart farm energy costs, has increased, requiring energy consumption efficiency, and the importance of new and renewable energy is increasing due to concerns about the realization of electricity bills. Renewable energy belongs to hydropower, wind, and solar power, of which solar energy is a power generation technology that converts it into electrical energy, and this technology has less impact on the environment and is simple to maintain. In this study, based on the greenhouse heat storage tank and heat pump data, the factors that affect the heat storage tank are selected and a heat storage tank supply temperature prediction model is developed. It is predicted using Long Short-Term Memory (LSTM), which is effective for time series data analysis and prediction, and XGBoost model, which is superior to other ensemble learning techniques. By predicting the temperature of the heat pump heat storage tank, energy consumption may be optimized and system operation may be optimized. In addition, we intend to link it to the smart farm energy integrated operation system, such as reducing heating and cooling costs and improving the energy independence of farmers due to the use of solar power. By managing the supply of waste heat energy through the platform and deriving the maximum heating load and energy values required for crop growth by season and time, an optimal energy management plan is derived based on this.

Non-Duplication Loading Method for supporting Spatio-Temporal Analysis in Spatial Data Warehouse (공간 데이터웨어하우스에서 시공간 분석 지원을 위한 비중복 적재기법)

  • Jeon, Chi-Soo;Lee, Dong-Wook;You, Byeong-Seob;Lee, Soon-Jo;Bae, Hae-Young
    • Journal of Korea Spatial Information System Society
    • /
    • v.9 no.2
    • /
    • pp.81-91
    • /
    • 2007
  • In this paper, we have proposed the non-duplication loading method for supporting spatio-temporal analysis in spatial data warehouse. SDW(Spatial Data Warehouse) extracts spatial data from SDBMS that support various service of different machine. In proposed methods, it extracts updated parts of SDBMS that is participated to source in SDW. And it removes the duplicated data by spatial operation, then loads it by integrated forms. By this manner, it can support fast analysis operation for spatial data and reduce a waste of storage space. Proposed method loads spatial data by efficient form at application of analysis and prospect by time like spatial mining.

  • PDF

THE DESIGN FEATURES OF THE ADVANCED POWER REACTOR 1400

  • Lee, Sang-Seob;Kim, Sung-Hwan;Suh, Kune-Yull
    • Nuclear Engineering and Technology
    • /
    • v.41 no.8
    • /
    • pp.995-1004
    • /
    • 2009
  • The Advanced Power Reactor 1400 (APR1400) is an evolutionary advanced light water reactor (ALWR) based on the Optimized Power Reactor 1000 (OPR1000), which is in operation in Korea. The APR1400 incorporates a variety of engineering improvements and operational experience to enhance safety, economics, and reliability. The advanced design features and improvements of the APR1400 design include a pilot operated safety relief valve (POSRV), a four-train safety injection system with direct vessel injection (DVI), a fluidic device (FD) in the safety injection tank, an in-containment refueling water storage tank (IRWST), an external reactor vessel cooling system, and an integrated head assembly (IHA). Development of the APR1400 started in 1992 and continued for ten years. The APR1400 design received design certification from the Korean nuclear regulatory body in May of2002. Currently, two construction projects for the APR1400 are in progress in Korea.

Integrated Operation of DC Distribution System for Building Application (빌딩에 적용되는 DC 배전 시스템의 통합 운전)

  • Han, Dong-Woo;Shin, Soo-Cheol;Lee, Hee-Jun;Won, Chung-Yuen;Lee, Taeck-Kie
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.57-58
    • /
    • 2013
  • 본 논문에서는 빌딩과 같은 건축물에 적용될 DC 배전 시스템의 통합 운전에 대하여 제안 및 분석을 하였다. 제안하는 DC 배전 시스템은 AC/DC 전력 변환 모듈 2개와 하나의 ESS (Energy Storage System) 모듈이 병렬로 연결 되어있으며, ESS와 부하의 상태에 따라 적합한 운전 모드로 동작 하게 된다. ESS와 부하의 상태는 시뮬레이션을 통해 모의하였으며, 제안된 시스템은 각 상황에 대응하는 제어가 원활히 이루어지는 것을 검증하였다.

  • PDF

Classification of hydropower dam in North-han River based on water storage characteristics (저류특성을 고려한 북한강수계 발전용댐의 유형 구분방안 제시)

  • Choi, Jeongwook;Jeong, Gimoon;Kang, Doosun;Ahn, Jeonghwan;Kim, Taesoon
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.8
    • /
    • pp.567-576
    • /
    • 2021
  • Climate change threatens the security of domestic water resources in South Korea. To overcome the potential water shortage, various approaches are being studied by alterning the operation of dams or by integrated operation of multiple dams and reservoirs. However, most of the related researches were developed and applied for multi-purpose dams, and few studies were conducted for the hydropower dams. The main purpose of the hydropower dam is to generate electric energy; however, the potential water shortage due to prolonged droughts brings the idea to supply water from the hydropower dam in the basin. To that end, it is required to estimate the water supply ability of the hydropower dams. In this study, we proposed a methodology to classify the hydropower dam into a "storage-type" and "run-of-river type" dam. The proposed approach was demonstrated using the hydropower dams located in North-han River basin. The results of this study are expected to contribute for further analysis of the hydropower dams, such as evaluation of water supply capacity and drought mitigation purpose operation of the hydropower dams.