• Title/Summary/Keyword: Integral Ratio

Search Result 328, Processing Time 0.021 seconds

Study on Engine-CVT Consolidated Control(II)-Experimental Study (엔진-CVT 통합제어에 관한 연구(II)-실험적 연구)

  • 김달철;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.6
    • /
    • pp.111-119
    • /
    • 1997
  • In this paper, engine-CVT consolidated control performance were investigated experimentally. Engine-CVT consolidated control was composed of engine throttle control based on power difference and CVT ratio control based on CVT ratio map. Experimental results showed that engine optimal operation was obtained while satisfying the driver's desire, i. e., following the given drive mode by engine-CVT consolidated control. Also, it was found that engine performance is subjected to inertia of the powertrain where the magnitude of acceleration changes abruptyly. Comparing with the results of CVT only control, the results of engine-CVT consolidated control showed better performance. Therefore, in order to meet the driver's desire as well as keeping the engine optimal operation, the engine-CVT consolidated control could be suggested as an integral solution.

  • PDF

Stability of superconductor by integration formula

  • Seol, S.Y.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.3
    • /
    • pp.1-5
    • /
    • 2019
  • The superconductor stability theories are consistently described by the integral formula. If the defined stability function is a simple decreasing function, it becomes a cryogenic stability condition. If the stability function has a maximum value and a minimum value, and the maximum value is less than 0, then it is a cold-end recovery condition. If the maximum value is more than 0, it can be shown that the unstable equilibrium temperature, that is, the MPZ (minimum propagation zone) temperature distribution can exist. The MPZ region is divided into two regions according to the current ratio. At the low current ratio, the maximum dimensionless temperature is greater than 1, and at the relatively high current ratio, the maximum dimensionless temperature is less than 1. In order to predict the minimum quench energy, the dimensionless energy was obtained for the MPZ temperature distribution. In particular, it was shown that the dimensionless energy can be obtained even when the MPZ maximum temperature is 1 or more.

Validation of an asymptotic zone conditional expression for turbulent burning velocity against DNS database (영역조건평균에 기초한 난류연소속도의 직접수치해법검증)

  • Kim, Soo-Youb;Huh, Kang-Y.
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.62-69
    • /
    • 2004
  • Zone conditional formulations for the Reynolds average reaction progress variable are used to derive an asymptotic expression for turbulent burning velocity. New DNS runs are performed for validation in a statistically one dimensional steady state configuration. Parametric study is performed with respect to turbulent intensity, integral length scale, density ratio and laminar flame speed. Results show good agreement between DNS results and the asymptotic expression in terms of measured maximum flame surface density and estimated turbulent diffusivity in unburned gas.

  • PDF

Validation of an asymptotic zone conditional expression for turbulent burning velocity against DNS database (영역조건평균에 기초한 난류연소속도의 직접수치해법검증)

  • Kim, Soo-Youb;Huh, Kang-Y.
    • Journal of the Korean Society of Combustion
    • /
    • v.9 no.4
    • /
    • pp.1-8
    • /
    • 2004
  • Zone conditional formulation for the Reynolds average reaction progress variable is used to derive an asymptotic expression for turbulent burning velocity. New DNS runs are performed for validation in a statistically one dimensional steady state configuration. Parametric study is performed with respect to turbulent intensity, integral length scale, density ratio and laminar flame speed. Results show good agreement between DNS results and the asymptotic expression in terms of measured maximum flame surface density and estimated turbulent diffusivity in unburned gas.

  • PDF

The Limit Distribution of a Modified W-Test Statistic for Exponentiality

  • Kim, Namhyun
    • Communications for Statistical Applications and Methods
    • /
    • v.8 no.2
    • /
    • pp.473-481
    • /
    • 2001
  • Shapiro and Wilk (1972) developed a test for exponentiality with origin and scale unknown. The procedure consists of comparing the generalized least squares estimate of scale with the estimate of scale given by the sample variance. However the test statistic is inconsistent. Kim(2001) proposed a modified Shapiro-Wilk's test statistic based on the ratio of tow asymptotically efficient estimates of scale. In this paper, we study the asymptotic behavior of the statistic using the approximation of the quantile process by a sequence of Brownian bridges and represent the limit null distribution as an integral of a Brownian bridge.

  • PDF

Control of Daily Integral PPE by the Artificial Lighting and shading screen In Greenhouse (인공광 및 차광스크린을 이용한 온실의 일일적산 광합성유효광량자속 조절)

  • 이현우
    • Journal of Bio-Environment Control
    • /
    • v.12 no.1
    • /
    • pp.45-53
    • /
    • 2003
  • The object of this study was to develop the control technology of daily integral photosynthetic photon flux (PPF) by the artificial lighting and shading screen in greenhouse. The shading time needed to get the target PPF by using two types of shading screens having shading ratio of 55% and 85% was analyzed. The results showed the shading ratio of screen to be installed in greenhouse should be different depending on the amount of target PPF to be controlled. The PPF control experiment by using the 55% shading screen in July and August showed that the maximum difference between measured and calculated value was about 5 mol$.$ $m^{-2}$ $.$ $d^{-1}$ in no shading condition. This difference is satisfactory result because the daily integral PPF is quite different depending on the weather condition. The simulation result about PPF distribution pattern shortened the time needed to find the proper arrangement of artificial lightings in greenhouse. But the further study was required to find the supplemental lighting arrangement to be able to provide the exactly uniform distribution of target light intensity. The supplemental irradiation time needed to acquire the target daily integral PPF for different supplemental light intensities, weather conditions, and months was analyzed. The result showed that the supplemental light intensity should be decided depending on the amount of target PPF to be controlled. The result of PPF control experiment conducted by using 55% shading screen and 300 $\mu$mol$.$ $m^{-2}$ $.$ $s^{-1}$ supplemental light intensity from the end of May to the beginning of June showed that the maximum difference between target and measured value was about 3 mol$.$ $d^{-1}$ $.$ $m^{-2}$ . If we consider that the difference of the daily integral PPF depending on weather condition was the maximum 30 mol$.$ $m^{-2}$ $.$ $d^{-l}$, the control effect was acceptable. Although the result of this study was the PPF control technology to grow lettuce, the data and control method obtained could be employed for other crop production.n.

Turbulent Flow over 2-D Rectangular-Shaped Roughness Elements with Various Spacings(Part 2 : Turbulence, Friction Velocity and Integral Parameters) (사각단면을 갖는 환경 거칠기 요소의 거칠기 간격에 따른 유동 변화(제2보 : 난류, 마찰속도 및 적분변수))

  • Hyun B.S.;Suh E.J.;Moon J.S.;Kim G.W.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.2
    • /
    • pp.85-91
    • /
    • 2006
  • This study deals with the flow over a flat plate with repeated roughness elements of 2-dimensional rectangular shape, which can be applied into the study on the natural geographical roughness and the turbulent flow on roughened solid surface. Part 1 of the study showed that the ratio between the spacing and the height of roughness elements plays a crucial role in developing the flow pattern near wall surface. The present study complements the turbulence characteristics, the utilization of friction velocity as well as integral parameters. Results confirmed that k-type roughness(s/H=7 or 14) is certainly a more effective means than d-type roughness (s/H=3.5) in thickening the viscous region.

  • PDF

Thermal-hydraulic Design of A Printed-Circuit Steam Generator for Integral Reactor (일체형원자로 인쇄기판형 증기발생기 열수력학적 설계)

  • Kang, Han-Ok;Han, Hun Sik;Kim, Young-In
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.6
    • /
    • pp.77-83
    • /
    • 2014
  • The vessel of integral reactor contains its major primary components such as the fuel and core, pumps, steam generators, and a pressurizer, so its size is proportional to the required space for the installation of each component. The steam generators take up the largest volume of internal space of reactor vessel and their volumes is substantial for the overall size of reactor vessel. Reduction of installation space for steam generators can lead to much smaller reactor vessel with resultant decrease of overall cost for the components and related facilities. A printed circuit heat exchanger is one of the compact types of heat exchangers available as an alternative to conventional shell and tube heat exchangers. Its name is derived from the procedure used to manufacture the flat metal plates that form the core of the heat exchanger, which is done by chemical milling. These plates are then stacked and diffusion bonded, converting the plates into a solid metal block containing precisely engineered fluid flow passages. The overall heat transfer area and pressure drops are evaluated for the steam generator based on the concept of the printed circuit heat exchanger in this study. As the printed circuit heat exchanger is known to have much larger heat transfer area density per unit volume, we can expect significantly reduced steam generator compared to former shell and tube type of steam generator. For the introduction of new steam generator, two design requirements are considered: flow area ratio between primary and secondary flow paths, and secondary side parallel channel flow oscillation. The results show that the overall volume of the steam generator can be significantly reduced with printed circuit type of steam generator.

Revisit on Experimental Conditions in Determination of Stress Intensity Factor and the J-Integral Using the Methods of Caustics (응력확대계수와 J-적분 결정을 위한 코스틱스방법의 실험조건에 관한 연구)

  • 이억섭;조종두;홍성경
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.9
    • /
    • pp.2331-2338
    • /
    • 1994
  • Experimental conditions of the optical shadow methods of caustics for measurement of the stress intensity factor and the J-integral in various materials(polycarbonate, PMMA, Al 5586D) are investigated. The necessary experimental requirements toe determine accurate values of the stress intensity factors and the J-integrals are described. The ratio of $r_o$ (radius of initial curve) to $r_p$ (plastic zone size) is selected as a parameter to verify the experimental limitation of the method of caustics in determination of fracture parameters. In this study, transmission caustics method was used for compact tension specimens made of polycarbonate and PMMA. while reflection caustics method was applied to c-shaped tension specimen made of Al 5586D. The appropriate ranges of $r_o/r_p$ tp determine accurate values of stress intensity factors were found to be 1.5~1.8. Existing experimental results have been obtained mainly by changing $r_p$ with different loads in $r_o/r_p$. However, in this study we could obtain varying $K_{caus}/K_{th}$ over the wide range of $r_o/r_p$ at fixed load conditions with newly designed optical arrangement. Thus, we could find the range in which theoretical and experimental results agree well each other by changing $r_o$ values only. In Al 5586D specimen, experimental caustics were located inside of the plastic zone, and $K_{caus}/K_{th}$ were found to be not unity in this range. It is found that $J_{caus}/J_{th}=1{\;}with{\;}r_o/t{\geq}0.8$ and the experimental plastic zone includes the contours of caustics.

Dielectric Breakdown Analysis of Bone-Like Materials with Conductive Channels (전도채널을 갖는 뼈와 유사한 재료의 절연파괴 해석)

  • Lee, Bo-Hyun;Lin, Song;Beom, Hyeon-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.6
    • /
    • pp.583-589
    • /
    • 2011
  • The dielectric breakdown of bone-like materials subject to purely electric fields is investigated. In general, these materials consist of some layers with stronger dielectric strength and others with weaker dielectric strength in a parallel staggered pattern. The growth of the conductive channel is impeded during penetration of the weaker layer in the bone-like material because the electric-field concentration is relieved. The electric-field distribution around the head of the tubular channel is obtained from finite element analysis. The dielectric strength of the bone-like material is evaluated using the J integral, and some parameters affecting the dielectric strength are determined. It is shown that the J-integral values are reduced with an increase in the breakdown area in the weaker layer. It is also found that the ratio of the permittivity of the weaker layer to that of the stronger layer can strongly affect the dielectric breakdown.