• Title/Summary/Keyword: Intake air pressure

Search Result 198, Processing Time 0.023 seconds

Low-noise Design of Passage of Idle Speed Control Actuator In Automotive Engines Using Scaling Laws for Noise Prediction (소음예측 비례식을 이용한 자동차 엔진 공회전 속도 제어 장치 유로의 저소음 설계)

  • Cheong, Cheol-Ung;Kim, Jae-Hyun;Kim, Sung-Tae;Park, Yong-Hwan;Lee, Soo-Gab
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.8
    • /
    • pp.683-692
    • /
    • 2007
  • Recently, plastic products in air-intake parts of automotive engines have become very popular due to advantages that include reduced weight, constricted cost, and lower intake air temperature. However, flow-induced noise in air-intake parts becomes a more serious problem for plastic intake-manifolds than for conventional aluminum-made manifolds. This is due to the fact that plastic manifolds transmit more noise owing to their lower material density. Internal aerodynamic noise from an idle speed control actuator(ISA) is qualitatively analyzed by using a scaling law, which is expressed with some flow parameters such as pressure drop, maximum flow velocity, and turbulence kinetic energy. First, basic flow characteristics through ISA passage are identified with the flow predictions obtained by applying computational fluid dynamics techniques. Then, the effects on ISA passage noise of each design factors including the duct turning shape and vane geometries are assessed. Based on these results, the preliminary low noise design for the ISA passage are proposed. The current method for the prediction of internal aerodynamic noise consists of the steady CFD and the scaling laws for the noise prediction. This combination is most cost-effective, compared with other methods, and therefore is believed to be suited for the preliminary design tool in the industrial field.

Honeycomb and Laminated Mesh as Open Volumetric Solar Receiver : Performance of Heat Transfer and Pressure Drop (고온 태양열 공기식 흡수기의 충진재 변화에 따른 열전달 및 압력강하 성능 분석)

  • Cho, Ja-Hyun;Lee, Ju-Han;Kang, Kyung-Mun;Seo, Tae-Beom
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.11
    • /
    • pp.760-766
    • /
    • 2008
  • The characteristics of heat transfer and pressure drop of several different porous materials which can be used as inserts inside solar volumetric air receivers were experimentally investigated. Generally, porous materials were inserted into solar volumetric air receivers to increase the thermal performance. In the present work, honeycomb (diameter: 100 mm, thickness: 30 mm), laminated mesh (diameter: 100 mm, thickness: 1 mm) are considered as the inserts for the experiment. The experimental apparatus consists mainly of a cylindrical ceramic duct as a receiver and an electric heater as an energy source. This system is an intake open loop, which used as air of working fluid. The temperatures inside the ceramic tube are measured by thermocouples, which are installed at each layer of the porous materials. The pressure-drop experimental apparatus is fabricated alike the above experimental equipment. An acrylic tube is used like as the ceramic tube, which has the same specifications of the ceramic tube. The pressure drop of porous materials inserted in the acrylic tube is measured between front and rear of those by transmitter. The results show that the laminated mesh surpasses the honeycomb of heat transfer and pressure drop increase as the porous material thickness and Reynolds number.

The Study of Engine Output and Emission Characteristics according to Air Fuel Ratio far a Supercharged LPLi Engine (과급 LPLi 엔진의 공연비 변화에 따른 출력성능 및 배기특성에 관한 연구)

  • 류재덕;윤용원;이기형;이창식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.77-84
    • /
    • 2002
  • For the purpose of obtaining a fundamental data which is needed to develope the port injection type charged LPLi engine system, we manufactured intake port injection system of liquid charging LPG and modified heavy duty single cylinder LPLi engine from heavy duty diesel engine. Engine output and emission characteristics were analyzed under variable air/fuel ratio and charging pressure. Since LPG is consisted of propane and butane, we investigated combustion characteristics using this two kinds of fuel. From the result of charging engine performance test, engine torque increase about 30% ∼ 40% with 0.3bar charging pressure. In low speed condition, as charging pressure increase, combustion stability improve ill lean bum condition, but, in high speed condition, combustion stability make worse in lean bum condition. We know that engine output decreased rapidly from the condition of air excess ratio 1.3. In addition, we measured emission characteristics under the lean bum and charging condition. From this experiment, we found that CO emission is out of the question in the range from stiochiometric to lean burn and charging condition, but charging pressure has influence on HC emission.

A Fracture Analysis on the Ceramic Dome with Different Geometry under Impact (충격을 받는 세라믹돔의 기하형상에 따른 파괴해석)

  • Kwon, Sun-Guk;Lee, Yung-Shin;Kim, Jae-Hoon;Lee, Jung-Hee;Yoon, Su-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.706-710
    • /
    • 2008
  • The experiment of dome port cover under shock impact is performed with shock tube. The dome port cover blocked intake air duct up from the solid propellant during air breathing vehicle speed reach Mach 2.0. When the air breathing vehicle reach Mach 2.0, the inlet cover is removed and the dome port cover is broken to pieces by detonator or pressure of inlet air. Thus the dome port cover not only must stand the pressure of combustion chamber but also easy to break from the RAM pressure. In this study, a fracture evaluation on the $Al_2O_3$ ceramic spherical dome and circular plate port under impact has been presented. Ceramic were supported by the rigid body and a couple of O-ring. The Mooney-Rivlin model have been used to describe behaviors of both O-ring. And spherical dome and circular plate fracture results of the LS-DYNA code using Johnson-Holmquist(JH-2) constitutive equation was compared.

  • PDF

A Study on the combustion characteristcs for backpressure of exhaust system in SI engine (배기(排氣)시스템의 배압(背壓)과 연소특성(燃燒特性)에 관한 연구)

  • Park, Dai-Un;Park, Kyoung-Suk;Park, Se-Jong;Son, Sung-Man
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.206-212
    • /
    • 2004
  • It is necessary to consider the stability, economic environmental-friendly problems by the development of the road, supply of the automobile, environmental problem as designing the exhaust system. To reduce the noise and the vibration of the automobile, it is needed to consider the pulsation noise, air current noise, vibration of air pipe which generate the intake and exhaust noise of the automobile. Moreover, the discharge sounds, intake sound, radiation sound, transmitted sound are occurred. To reduce this influence, the variable valve is needed and to control these factors, path transformation muffler and active type muffler are needed. While engine efficiency could be reduced with this transformationand resistance by the pressure, thermal property. In this study, how to design exhaust systems yielding higher condversion efficiency, lower backpressure and optimize the performance. this study is recommended for exhaust system and designers and engineers involved in SI engine exhaust system and it will furnish information for you to design more efficient.

  • PDF

The Damage Reduction Strategy for Power Plant Using Air Bubble Barrier (에어버블 차단막을 이용한 발전플랜트 피해 저감 방안 연구)

  • Chang, Hyung Joon;Lee, Ho Jin;Lee, Hyo Sang;Hwang, Myung Gyu
    • Journal of Korean Society of Disaster and Security
    • /
    • v.11 no.1
    • /
    • pp.1-5
    • /
    • 2018
  • Power plant is the important infrastructure to generate electricity. This plant in normally located next to river and seashore in order to take cooling water through intake. However, the plant is stopped when marine organism blocks the intake, and it caused damages by social and commercial. Therefore, air bubble barrier has been used to block marine organism in order to operate the plant properly. The aim of this study was to test the rates of cut off of floating substance by air bubble barrier to develop the facility for the plant. The test was conducted by current velocity, pressure of air, specific gravity of the substance and the layer of the barrier, and the result showed the blocking rates by the condition. It will be used as basic data to develop the air bubble barrier and to operate power plant properly from the marine organism.

A Study on 2D Modelling of Gas Turbine Engine Intake for Installed Performance Analysis (가스터빈 엔진의 장착성능 해석을 위한 흡입구 2D 모델링에 관한 연구)

  • Kong, Chang-Duk;Kho, Seong-Hee;Ki, Ja-Young;Jun, Yong-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.335-338
    • /
    • 2007
  • This study carried out the 2D modeling for estimating the intake loss that is a important installed loss for the precise installed performance analysis of a gas turbine engine, and the 0D performance map that represents intake pressure loss change depending on flight Mach number and air mass flow rate was generated using the 2D modeling results. In order to evaluate the generation procedure of the intake performance map, the intake map generation was applied to a commercial aircraft intake configuration.

  • PDF

Operating Characteristics of Serially Connected Centrifugal Blowers Used for Automated Vacuum Waste Collection System (생활폐기물 자동집하시설용 다단직렬연결 원심블로어 운전특성)

  • Jang, Choon-Man;Lee, Jong-Sung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.4
    • /
    • pp.40-46
    • /
    • 2014
  • This paper describes blower performance characteristics of a automated vacuum waste collection system. Blowers serially connected to six or seven centrifugal blowers are evaluated by experimental measurements to understand blower performances according to blower numbers operated. Two different blowers and duct diameters connected to the main blowers are considered. Data acquisition system is introduced to measure pressure and pressure difference at the main duct simultaneously, which is connected to several blowers serially. A auxiliary blower, which is installed between a filter room and an air deodorizing apparatus, is also added to simulate its performance effect on the main blower. Throughout the experimental measurements of the blower system, it is found that pressure and inlet velocity at the upstream of a blower increase 3.7 and 2.4 times separately by increasing the operating blower numbers from one to seven. It is noted that blower efficiency and pressure measured at the system vary according to the distance between a air intake and a blower system. Auxiliary blower is effective to increase blower inlet suction pressure, while total energy consumption is increased relatively.

Improving the natural ventilation in multi-housing units of tower-type buildings according to their shapes and directions (탑상형 공동주택의 주동형태와 배치각에 따른 주호의 자연환기 성능)

  • Yoo, Seon-Yong;Kim, Ji-Yoeng;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.897-902
    • /
    • 2006
  • Natural ventilation is an effective method for improving IAQ(Indoor Air Quality) and removing heats in buildings. In oder to use natural ventilation, many factors such as wind pressure around the buildings and possibility of air intake on different shapes need to be known. On this paper, the natural ventilation performance in multi-housing units of tower-type buildings was investigated. Tower-type multi-housing buildings are recently more and more constructed for they may change urban landscape and get more openness in multi-housing site. However, such housing buildings have problems with natural ventilation because of the various directions of the building units. The purpose of this paper is to find the proper building direction regarding to wind direction in order to optimize air intake in every units in the building.

  • PDF

Reducing Exhaust Hydrocarbon at Gasoline Engine with Catalytic Converter using Synchronized Secondary Air Injection (촉매가 장착된 가솔린엔진에서 동기화된 2차공기분사에 의한 배기 탄화수소 저감)

  • 심현성;민경덕;정석호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.2
    • /
    • pp.67-74
    • /
    • 2001
  • A synchronized secondaty air injection method has been developed to hydrocarbon emission by injecting secondary air intermittently into exhaust port. The method has been tested in a single cylinder spark-ignition engine operating at cold-steady / cold-start conditions. Effects of air injection timing, intake pressure and engine air-fuel ratio have been investigated at cold-steady condition. Also, hydrocarbon emission and exhaust gas temperature with catalytic conberter are compared with a continuous SAI method and base condition at cold-start condition. Resules show that hydrocarbon reduction rate and exhaust gas temperature are sensitive to the timing of synchronized SAI. At cold-steady condition, HC emission is minimum at engine air-fuel ratio of 10. At cold-start condition, the accumulated hydrocarbon emission during the first 120 s decreases about 56% and 22% with the synchronized and continuous SAI, respectively, compared to that of base condition.

  • PDF