Abstract
This paper describes blower performance characteristics of a automated vacuum waste collection system. Blowers serially connected to six or seven centrifugal blowers are evaluated by experimental measurements to understand blower performances according to blower numbers operated. Two different blowers and duct diameters connected to the main blowers are considered. Data acquisition system is introduced to measure pressure and pressure difference at the main duct simultaneously, which is connected to several blowers serially. A auxiliary blower, which is installed between a filter room and an air deodorizing apparatus, is also added to simulate its performance effect on the main blower. Throughout the experimental measurements of the blower system, it is found that pressure and inlet velocity at the upstream of a blower increase 3.7 and 2.4 times separately by increasing the operating blower numbers from one to seven. It is noted that blower efficiency and pressure measured at the system vary according to the distance between a air intake and a blower system. Auxiliary blower is effective to increase blower inlet suction pressure, while total energy consumption is increased relatively.
Keywords
Centrifugal blower; Operating characteristics; Automated vacuum waste collection system; Efficiency; Pressure; Auxiliary Blower;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Jang, C.-M., Lee, S.-Y. and Suh, S.-H., 2007, "Pressure Drop in a Circular Pipe of Waste Collection Piping System," Journal of Fluid Machinery, Vol. 10, No. 4, pp. 55-60.   과학기술학회마을   DOI
2 Jang, C.-M., 2009, "Flow Characteristics of Piping System Having Various Shapes in Refuse Collection System," Journal of Fluid Machinery, Vol. 12, No. 3, pp. 13-18.
3 Jang, C.-M., 2010, "Optimal Design and Operation of a Turbo Blower Used for Refuse Collection System," Journal of Fluid Machinery, Vol. 13, No. 5, pp. 58-63.   과학기술학회마을   DOI
4 Bayomi, N. N., Abdel Hafiz, A., and Osman, A. M, 2006, "Effect of Inlet Straighteners on Centrifugal Fan Performance," Energy Conversion & Management, Vol. 47, pp. 3307-3318.   DOI   ScienceOn
5 Lee, J.-S., and Jang, C.-M., 2012, "Evaluation of Numerical Models for Analysing an Industrial Centrifugal Blower,", Journal of Trans. of Korean Hydrogen and New Energy Society, Vol. 23, No. 6, pp. 688-695.   과학기술학회마을   DOI   ScienceOn
6 Ong, H. L., Goh, T. N., Poh, K. L. and Lim, C. C., 1990, "A Computerized Vehicle Routing System for Refuse Collection," Adv. Eng. Software, Vol. 12, No. 2, pp. 54-58.   DOI
7 Basic Design Report of Automated Vacuum Waste Collection System at Incheon Cheongra. 2007.
8 Cesar, F., Felip, M., Carles, M. and Francina, S.-M. 2013, "Modeling Energy Consumption in Automated Vacuum Waste Collection Systems," Environmental Modelling & Software, http://dx.doi.org/10.1016/j.envsoft.2013.11.013.   DOI