• Title/Summary/Keyword: Insulators

Search Result 652, Processing Time 0.029 seconds

Evaluation and Performance Test of Ball and Socet type Suspension Insulator for 300 kN Ultra High Voltage (300kN 초고압용 초고압용 볼소켓형 현수애자의 성능평가)

  • Kim, S.S.;Kim, K.U.;Her, J.C.;Cho, H.G.;Park, T.G.;Seo, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2026-2028
    • /
    • 2000
  • As the results of evaluation of its performance for 300 kN Ball and Socket type suspension insulators. There was electrically internal puncture of the solid insulating body of the insulating due to the steep front impulse voltage, which usually occurs puncture before external flash-over of insulators, moreover we have obtained satisfactory results in power arc test of 7.2kA cycle fatigue test with high qualify control index of 4.6, especially we have obtained more satisfactory results than that before improvement of its materials.

  • PDF

Instrumentation based Neural Networks for Real-time detecting of Energized Insulator (오손 애자자의 실시간 검출을 위한 계측기반 신경망)

  • Kim, Jong-Man;Kim, Young-Min
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05c
    • /
    • pp.25-29
    • /
    • 2004
  • For detecting of Energized Insulator, a new Lateral Information Propagation Networks(LIPN) has been proposed. Faulty insulator is reduced the rate of insulation extremely, and taken the results dirty and injured. It is necessary to be actions that detect the faulty insulator and exchange the new one. And thus, we have designed the LIPN to be detected that insulators by the real time computation method through the inter-node diffusion. 1n the network, a node corresponds to a state in the quantized input space. Each node is composed of a processing unit and fixed weights from its neighbor nodes as well as its input terminal. Information propagates among neighbor nodes laterally and inter-node interpolation is achieved. Through the results of simulation experiments, we difine the ability of real-time detecting the faulty insulators.

  • PDF

A study on the External Insulation and Waterproof Method of Rooftop (옥상부 외단열 및 외방수 공법 제안에 관한 기초연구)

  • Jang, Dae-Hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.137-138
    • /
    • 2019
  • To overcome the limitation in relation to thermal insulator's selection and installation method that is suitable for exterior insulation and waterproof construction methods, a production basis of thermal insulators of which manufacturing knowhow is held by companies was ensured and future-oriented construction methods to adopt new materials were applied. Performance verification was conducted through performance and mock-up tests of thermal transmittance on the cross sections where the flexible insulators were applied based on the improved prototype and performance data were obtained. To overcome the biggest drawbacks (walking feeling and damage etc.) in the exterior insulation and waterproof construction method, inserting a protective layer between thermal insulator and water-proof layer was proposed, and polypropylene corrugated cardboards.

  • PDF

Development of a Ubiquitous Sensor for Monitoring Insulators and Arresters (애자/피뢰기 모니터링을 위한 유비쿼터스 센서 개발)

  • Kil, G.S.;Shin, G.C.;Park, J.K.;Sim, J.W.;Song, J.Y.
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.736-741
    • /
    • 2006
  • In this study, a ubiquitous sensor for condition monitoring of insulators and lightning arresters installed in power distribution lines and electric traction vehicles is presented. The sensor consists of two parts; a leakage current measurement and a lightning surge detection. Measured data are transmitted to a supervisory computer through ZigBee protocol based on IEEE 802.15.4. To detect leakage current, a window type Mn-ZCT is used and a low-noise amplifier with a gain of 60dB is designed, and this can measure leakage current in ranges of $100{\mu}A{\sim}5mA$. A sample-hold(S/H) and a Rogowski coil are injected to analyze the magnitude of surge current in ranges from 500A to 10kA with $8/20{\mu}s$-waveform.

  • PDF

The Evaluation of Surface Characteristics by Using Surface Discharge Method for Porcelain Suspension in Insulators (표면방전을 이용한 자기제 현수애자의 표면특성 평가)

  • 송일근;김찬영;한용희;윤영숭;안규선;임장섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.199-202
    • /
    • 1999
  • The paper deals with the surface discharge characteristics for porcelain suspension insulators. The micro-crystals were crystallized on the surface of glace coated on the porcelain These micro-crystals may affect the electrical Properties such as flashover voltage. However. not much research have been conducted. In this study. we correlated the surface discharge characteristics to the microstructures. It was confirmed that the micro-crystals on the glaze initiated the flashover when the surface was wetted and/or contaminated.

  • PDF

Characteristics of the break down current of HTS tape with different insulator (고온초전도선의 절연체에 따른 단선전류 특성)

  • Kim Jae H.;Bae J. H.;Cho J. W.;KIM H. J.;Sim K. D.;Seong K. C.;Kim H. J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1121-1123
    • /
    • 2004
  • Characteristics of the break down current of HTS tape with different insulator are described. The various insulators are utilized for enduring the high voltage in superconducting power devices. The break down current of HTS tape largely depends on insulators wound round HTS tape. In this research, The break down currents of Bi-2223 tape, which is widely used for superconducting power devices are tested and discussed. It is expected that results from this study can be utilized as basic data in designing superconducting power devices.

  • PDF

Analysis of Dielectric Characteristics of 400kN Suspension Insulator Using FEM (FEM을 이용한 400kN 현수애자의 절연특성 해석)

  • Choe, Jae-Gu;Kim, Ik-Su;Mun, In-Uk;Seo, Hyeong-Gwon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.2
    • /
    • pp.80-84
    • /
    • 2002
  • This paper presents some of the results of current research on 400kN Suspension Insulator Design. In this paper, authors carried out 2-dimensional field calculation in order to analyse dielectric characteristics of the insulator unit and 3-dimensional field calculation in order to analyse dielectric characteristics of the insulator strings. And the results of puncture tests of insulators were compared with the required field intensity of the insulator As results, it was found that electric field on the insulator unit is severest between two triple junctions, dielectric characteristics of insulator strings are much influenced by the surrounding configuration and the manufactured insulators have good results of puncture tests.

Reformation of Dielectric Property in interface between epoxy and Cu (Epoxy-Cu간 접촉면에서의 절연특성 개선)

  • 송재주;김성홍;정남성;황종선;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.9-12
    • /
    • 2000
  • Insulators for high-voltage and large-power should be endured mechanically the weight of mold bushing itself and the force of pushed from contact with circuit breaker and conductor. But dielectric breakdown could be occurred result from the external circumstances and internal factors such as chemical reaction, partial discharge, change of temperature and the relation of temperature-time in process of casting. Therefore, to get rid of external and internal factors of dielectric breakdown. Furthermore, to prevent the internal cracks, void, cavity which resulted from the contraction originated on the interface between copper and epoxy resin, formed semi-conductive layer with partially carbon painted on copper bar. The PD properties and the insulation qualities of epoxy molded insulators were improved by roles of cushions for the direction of diameter and natural sliding effects as like separated from conductor for the direction of length.

  • PDF

The Evaluation of Reliability through the Field Test of Pormeric Long Rod Insulator for Rail Way (전철용 고분자 장간애자의 실증 시험을 통한 신뢰성 평가)

  • 홍진영;김영성;백주흠;박찬기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.229-232
    • /
    • 1997
  • In this paper, we describe about the field test of polymeric long rod insulator for rail way. For the test, insulators were mounted at the feeder line system at Kuro base station and were exposed to environmental, electric, and mechanical stress. During the test service, the leakage current was been monitoring and stored the data by the leakage current measuring system that was specially constructed. After about 6 months, diagnostic tests for evaluation of the installed insulators were conducted. The test results developed that the developed polymeric insulator is valid to use for rail way.

  • PDF

Evaluation Technology of Electrical and reliableility Characteristics for Outdoor Polymer Insulator Materials (폴리머 절연물 소재의 전기적 밀 복합열화 특성평가 기술)

  • Ahn, Myeong-Sang;Park, Hoy-Yul;Na, Moon-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1343-1344
    • /
    • 2006
  • There have been numerous accelerated aging laboratory tests for evaluating suitability of polymeric materials and devices. Aging test for materials and its full scale device has been conducted. Service experience plays a key role in the utility section of composite insulators. A meaningful and reliable accelerated aging test is needed for evaluating composite insulator. During the service these insulators are subjected to aging stress such as humidity, pollution, and electrical field, and erosion and tracking of the weathershed occurs. This paper presents the criteria of reliability evaluation and evaluation facilities for 22.9 kV suspension composite insulator. We adopt the criteria of reliability evaluation consist of two test methods. One is CEA tracking wheel test for examining the tracking and erosion performance of composite insulator. The other is multi-stress aging test for examining effects of environmental factors such as UV, temperature, humidity, etc on composite insulator.

  • PDF