Impact Damage Characteristics and Assessment of Insulators Due to Hitting Tester (타격시험기에 의한 애자 파손특성과 평가)

  • Shong, Kil-Mok;Kim, Jong-Min;Kim, Young-Seok;Jeon, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.191-192
    • /
    • 2008
  • In this paper, we investigated on the characteristics and assessment of the insulators damaged by hitting tester(ST-100, Sharp-Eng, KOR). It made that an apparatus act on KS C 3801 for the damaged characteristics and assessment of insulators according to external scattering objects. There are selected 255mm glass insulators and 254mm porcelain insulators as the specimen. The hitting angles of the damaged insulator by pendulum weight are at $72^{\circ}$. At these points, velocity of pendulum weight is about 3.04m/sec and the force is 58.16N. At the hitting angle of 26 degrees, glass insulator is diffused the vibration within it but porcelain insulator is not. The inside vibrations of glass insulator and porcelain insulator are as like as two at the hitting angle of 53 degrees. The damaged glass insulator at the hitting angle of 72 degrees hardly is not diffused.

  • PDF

A study on the safety of the Environment Corrosion of Suspension Insulater of a Catenary Trolley Wire Systems (카테나리 전차선로 현수애자의 환경부식에 따른 안전성 연구)

  • Lee, Jae-Bong;So, Sun-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.864-874
    • /
    • 2007
  • Suspension insulator in Catenary Trolley Wire Systems must have two characteristics, electric insulation and mechanical endurance. Because suspension insulator is used in supporting and insulating position between power supply parts and earth conducted supporting parts. The insulator's electric characteristics can be influenced by surface pollution and damage from the environment such as humidity, dust, smoke, salt. etc. And, the insulating parts can be electrically short. These electrically damaged insulator can cause serious accidents that have far-reaching effect. So appropriate management basis of suspension insulator is needed. And we present appropriate cleaning and the changing period of suspension insulator on the basis of actual data.

  • PDF

Analysis on Damage of Porcelain Insulators Using AE Technique (AE기법을 이용한 자기애자의 손상 분석)

  • Choi, In-Hyuk;Shin, Koo-Yong;Lim, Yun-seog;Koo, Ja-Bin;Son, Ju-Am;Lim, Dae-Yeon;Oh, Tae-Keun;Yoon, Young-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.231-238
    • /
    • 2020
  • This paper investigates the soundness of porcelain insulators associated with the acoustic emission (AE) technique. The AE technique is a popular non-destructive method that measures and analyzes the burst energy that occurs mainly when a crack occurs in a high-frequency region. Typical AE methods require continuous monitoring with frequent sensor calibration. However, in this study, the AE technique excites a porcelain insulator using only an impact hammer, and it applies a high-pass filter to the signal frequency range measured only in the AE sensor by comparing the AE and the acceleration sensors. Next, the extracted time-domain signal is analyzed for the damage assessment. In normal signals, the duration is about 2ms, the area of the envelope is about 1,000, and the number of counts is about 20. In the damage signal, the duration exceeds 5ms, the area of the envelope is about 2,000, and the number of counts exceeds 40. In addition, various characteristics in the time and frequency domain for normal and damage cases are analyzed using the short-time Fourier transform (STFT). Based on the results of the STFT analysis, the maximum energy of a normal specimen is less than 0.02, while in the case of the damage specimen, it exceeds 0.02. The extracted high-frequency components can present dynamic behavior of crack regions and eigenmodes of the isolated insulator parts, but the presence, size, and distribution of cracks can be predicted indirectly. In this regard, the characteristics of the surface crack region were derived in this study.

Study on the application of antenna method for the criterion test of insulator arc resistance (절연체의 내아크성 평가를 위한 안테나 기법의 적용에 관한 연구)

  • Lee, K.W.;Kim, M.Y.;Kang, S.H.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.57-60
    • /
    • 2004
  • Electrical arc is the final stage of insulation breakdown and has high current density which cause heat and light in insulator. Insulator under electrical arc lost its insulating strength and eternal damages. Conventional criterion of electrical arc resistance in Standards have depended on the change of sound pressure and light color after damages on insulator by electrical arc. The recognition of these changes is done by human himself which was very subjective and resulted in some error to judge whether insulator has damages or not. This paper has shown that antenna method is the appropriate measure to judge electrical arc resistance for insulator. Antenna measures the electromagnetic waves radiated from tungsten electrodes with 6mm gap regulated by KSC2130. Applied voltage cross two tungsten electrodes have two different methods such as 1/8 10 and continuous 10mA. Signal amplitudes obtained by antenna has diminished after the damage of insulator, which will provide objective and good way to judge the electrical arc resistance.

  • PDF

A study of the Influence of Forest Fire on Polymer Insulator for UHV (초고압용 폴리머 애자의 산불영향 연구)

  • Choi, In-Hyuk;Choi, Jang-Hyun;Jung, Yoon-Hwan;Lee, Dong-Il
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.254-259
    • /
    • 2005
  • Big fire such as mountain fire my cause the prevention of the functions of the overhead cables and insulators, which may affect the operation of the transmission lines. Therefore, in order to understand the effect of the mountain fire on the polymeric insulator for transmission lines, the author observed the deformation of the sheds of the polymeric insulators and the change of the discs of the porcelain insulators under fire, and investigated the electrical and mechanical characteristics of the insulators after the ignition test. As the result the following conclusions were obtained. First, the porcelain insulator was degraded in electrical characteristics when the insulator was subjected to the fire for approximately 5 minutes; whereas, the polymeric insulator was not degraded though there were some damage on its sheds. Second, after 20 minute exposure to the fire, the polymeric insulator lost a lot of parts of sheds, but the electrical characteristics was lowered by around 20%, but the porcelain insulators were electrically degraded by more than 80%.

  • PDF

Effects of Process Induced Damages on Organic Gate Dielectrics of Organic Thin-Film Transistors

  • Kim, Doo-Hyun;Kim, D.W.;Kim, K.S.;Moon, J.S.;KIM, H.J.;Kim, D.C.;Oh, K.S.;Lee, B.J.;You, S.J.;Choi, S.W.;Park, Y.C.;Kim, B.S.;Shin, J.H.;Kim, Y.M.;Shin, S.S.;Hong, Mun-Pyo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1220-1224
    • /
    • 2007
  • The effects of plasma damages to the organic thin film transistor (OTFT) during the fabrication process are investigated; metal deposition process on the organic gate insulator by plasma sputtering mainly generates the process induced damages of bottom contact structured OTFTs. For this study, various deposition methods (thermal evaporation, plasma sputtering, and neutral beam based sputtering) and metals (gold and Indium-Tin Oxide) have been tested for their damage effects onto the Poly 4-vinylphenol(PVP) layer surface as an organic gate insulator. The surface damages are estimated by measuring surface energies and grain shapes of organic semiconductor on the gate insulator. Unlike thermal evaporation and neutral beam based sputtering, conventional plasma sputtering process induces serious damages onto the organic surface as increasing surface energy, decreasing grain sizes, and degrading TFT performance.

  • PDF

Damage Evaluation of Porcelain Insulators Using the Frequency Response Function (주파수응답함수(FRF)를 이용한 자기 애자의 손상평가)

  • Choi, In-Hyuk;Son, Ju-Am;Oh, Tae-Keun;Yoon, Young-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.2
    • /
    • pp.122-128
    • /
    • 2019
  • Porcelain insulators have been used mainly for power line fixing and electrical insulation in transmission towers. Porcelain insulators have generally a 30 years desired life, but over 50% exceed their life expectancy. Since the damage to porcelain insulators is usually accompanied by enormous loss of human resource material, their efficient maintenance has emerged as an important issue. In this regard, this study applied a frequency response function (FRF) for integrity assessment of the insulator. The characteristics of the FRF according to damage types were identified and analyzed by the change in natural frequencies, curve shape, attenuation, and Nyquist diagram stability. The results showed significant differences in the FRF according to damage types, which can be used as basic data for the effective integrity assessment of porcelain insulators.

Performance Evaluation of Polymer Insulator using Tracking Wheel and Multi-Aging Test (트래킹 휠과 복합열화시험에 의한 폴리머 애자의 성능 평가)

  • 조한구;안명상;한세원;허종철;이운용
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.119-122
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. Polymer insulators are a relatively new technology, but their expected life is still unknown. Therefore these estimating technique are very important. Their life time is related to weathering and operating condition. Multi-aging test is requested because aging factor is occurred by multi-aging than unique aging. The aging test about polymer insulators have mainly carried out by IEC 61109. This paper presents multi-stress chamber experiments and tracking wheel test to examine the tracking and erosion performance of polymer insulator for transmission. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs, including the nature of interfaces in insulation design. We have investigated IEC 61109 Annex C (5000h aging test) and CEA tracking wheel test as test methods of artificial accelerated aging. The aging degree of polymer insulator is estimated by leakage current, measurement of hydrophobicity degree, damage conditions of insulator surface, withstand voltage test etc.

  • PDF

Influence of Partial Discharge Properties due to Void in Cable Joint Parts (케이블 접속재 부분방전 특성에 미치는 보이드의 영향)

  • 신종열;홍진웅
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.69-74
    • /
    • 2003
  • To investigate the partial discharge and electric field distribution in cable joint parts, we measured the partial discharge and electric field in specimen. The specimens which cross-linked polyethylene(XLPE) and ethylene propylene diene ethylene(EPDM) are used to insulating material for underground cable md cable jointing parts. The polymers are used to insulating material in switchgear which is a kind of transformer equipment and in ultra-high voltage cable. Its using is increasing gradually, the electrical insulation properties are not only excellent but also mechanical property is excellent. And because it is possible to be made void of several type in insulator while it is produced, which the electrical field distribution is changed by void, it has a critical influence to insulator performance. The underground cable is connecting by the jointing material, insulating breakdown and the electric ageing which are caused by several mixing impurity and the damage of cable insulator layer, which reduced the life of cable while intermediate joint kit is connected. Therefore, the computer simulation is used to estimating insulator performance, XLPE is used to the insulating material of ultra-high voltage cable and EPDM is used to insulator layer in joint material kit, and which are produced as specimen. And it is analyzed the electric field concentrating distribution and partial discharge by modeling of computer simulation in void and cable joint kit.

The Influence of Forest Fire on the Characteristics of Polymer Insulator for Transmission Lines (산불영향에 따른 송전용 폴리머애자의 특성)

  • Lee Donu-Il;Chung Yong-Woon;Yu Kun-Yang;Choi In-Hyuk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.3
    • /
    • pp.127-131
    • /
    • 2005
  • Big fire such as mountain fire may cause the prevention of the functions of the overhead cables and insulators, which may affect the operation of the transmission lines. In the worst case, this kind of disaster may have a huge effect on the whole industry of a country. However, the study on the effect of the mountain fire on the transmission line is very rare. Therefore, in order to understand the effect of the mountain fire on the polymeric insulator for transmission lines, the author observed the deformation of the sheds of the polymeric insulators and the change of the discs of the porcelain insulators under fire, varying the ignition time using the artificial ignition testing equipment which simulates the mountain fire, and investigated the electrical and mechanical characteristics of the insulators after the ignition test. For the test, the miniature insulators made of polymeric material and porcelain have been utilized. As the result, the following conclusions were obtained. First, the porcelain insulator was degraded in electrical characteristics when the insulator was subjected to the fire for approximately 5 minutes; whereas, the polymeric insulator was not degraded though there were some damage on its sheds. Second, after 20 minute exposure to the fire, the polymeric insulator lost a lot of parts of sheds, but the electrical characteristics was lowered by around $20\%$, but the porcelain insulators were electrically degraded by more than $80\%$.