Comparative Study on Conductivity and Moisture Content Using Polarization and Depolarization Current (PDC) Test for HV Insulation

  • Jamail, N.A.M.;Piah, M.A.M.;Muhamad, N.A.;Kamarudin, Q.E.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.1
    • /
    • pp.7-11
    • /
    • 2014
  • The Polarization and Depolarization Current (PDC) measurement is an efficient and effective diagnostic technique based on time domain measurement, for evaluating the high voltage insulation condition. This paper presents a review and comparison results from several published papers on the application of the PDC method to finding the conductivity and moisture content of various types of insulators. For solid insulation, the study was focused on cable insulation, electric machine stator insulation, and paper insulator in transformer insulation with different conditions. For liquid insulation, the review and comparison was done on biodegradable and mineral transformer oils, with fresh oil condition, and aged condition. The results from previous researchers tests were complied, analyzed and discussed, to evaluate the application of the PDC method to monitor the conductivity and moisture of HV equipment insulation systems. From the review results, the PDC technique successfully gives an indication of the conductivity and moisture level of high voltage insulation.

A Basic Study on the Application of Partial Discharge Test on Low-voltage Electrical and Electronic Devices (저압용 전기전자기기에 부분방전시험의 적용을 위한 기초연구)

  • Kil Gyung-Suk;Song Jae-Yong;Moon Seung-Bo;Cha Myung-Soo;Hwang Don-Ha;Kang Dong-Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.586-590
    • /
    • 2006
  • This paper deals with the application of a partial discharge (PD) test on low-voltage electrical and electronic devices, which is recently being accepted as a non-destructive and a effective dielectric test method. A comparative analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards was carried out on low-voltage insulation transformers. The results showed that the WVT causes insulation degradation of the specimen during the test by applying high voltage. However, the PD test can be performed in ranges from 30 % to 50 % of the test voltage specified in the WVT. Therefore, the PD test is successfully applicable for a non-destructive test method on low-voltage electrical and electronic devices as a replacement of the WVT.

Analytic Issues for Trend Management on Insulation Diagnositic for High Voltage Motors (고압전동기 절연진단 결과 추이관리의 문제점 분석)

  • Lee, Young-Jun;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2052-2053
    • /
    • 2008
  • High voltage motors are the core equipment of electric generation facilities and need to guarantee stable operation. Therefore, keeping healthy state is of importance by means of insulation diagnosis periodically. However, if the diagnosis went through in the different circumstances such as temperature, humidity, and impedance applied to the test equipment, the trend analysis have no significance. This paper presents the experimental results supporting the importance of keeping the same conditions under insulation diagnosis.

  • PDF

A Study on the Image Processing for Effective Insulation Material Degradation Testing (효과적인 절연재료 열화검사를 위한 영상처리에 관한 연구)

  • 정기봉;오무송;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.230-233
    • /
    • 1999
  • Because Insulation material is play an important part for normal work of electricity equipment, the study is advanced, but as the voltage of electricity system is raising, we required that new lnsulation material. They have excellent specific against high stress, namely the study of insulation increase and prevention diagnosis of insulation degradation of Epoxy or XLPE and so on. In this thesis. I utilize image processing technique for effective inspection of insulation material degradation.

  • PDF

Study on insulation coordination of 154KV solidly grounded system (154KV계 직접접지시의 절연협조)

  • 신대승
    • 전기의세계
    • /
    • v.17 no.3
    • /
    • pp.57-61
    • /
    • 1968
  • Limitation to Peterson coil grounded operation of 154KV system began to develop with the growth of system as to voltage and system cost. Therefore, 154KV system is going to be grounded solidly from November this year. This study shows the insulation coordination of solidly ground system, such as the selection of a suitable lightening arrester, determination of transmission line insulation and Basic Insulation Level of station equipment.

  • PDF

A Study of PBD and BD Voltage Characteristics in the Simulate Electrode System of Solenoid Type High Temperature Superconducting Coils (솔레노이드형 고온초전도코일 모의전극계에서 부분 및 완전파괴전압특성 연구)

  • 석복렬
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.94-98
    • /
    • 2002
  • The Partial breakdown (PBD) and complete breakdown (BD) voltage characteristics in a composite insulation system of glass fiber reinforced plastics (GFRP) and liquid nitrogen are investigated to find the PBB and BD characteristics in solenoid type high temperature superconducting (HTS) coils at quench. The electrode system used is made from a coaxial spiral coil-to-cylindrical electrode with an insulation barrier and spacers, and is immersed in liquid nitrogen. A heater is mounted inside the coil electrode to generate boiling which occurs on quenched superconducting coils. The experimental results show that: (1) breakdown voltages are affected severely by the risetime of the applied voltage and the PBD inception voltage, (2) two kinds of BD mechanisms are found depending on the shape of the spacer, length of cooling channel and heater power.

Study about Electrical Insulation and earthing system of Bimodal Tram with Polymer Composite Body (고분자복합소재차체를 적용한 바이모달트램의 전기적 절연 및 접지시스템에 관한 연구)

  • Lee, Kang-Won;Mok, Jai-Kyun;Kil, Gyung-Suk;Park, Dae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1063-1064
    • /
    • 2008
  • Bimodal tram has a carbody made of polymer composite material which is good electrical insulator. As an series hybrid type, Alternating voltage generated from generator coupled with CNG engine are rectified and transformed to variable voltage ranges which are applied to electrical apparatus and ECUs equipped inside of the tram. The failures of electrical insulation between high voltage($400V{\sim}800V$) and low voltage(24V) or between different kind of voltages such as AC and DC may cause some electrical interferences to prevent from operating rightly and other safety problem. This paper have investigated about the degradation factors of the electrical insulation and the earthing method available to bimodal tram, which is effective for preventing the electromagnetic interference coming from the inside or outside of tram but need some detecting measurements of earth leakage through electrical systems.

  • PDF

Insulation Coordination of Forced Drainage in Electric Railway (직류방식 전기철도에서 강제배류기의 절연협조)

  • Min, B.H.;Eo, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.446-448
    • /
    • 1999
  • The forced drainage set up to decrease the cathodic protection in each kind of steel conduit laid under the ground is so proscribed to be maintained less than 60V in its output voltage that insulation coordination is easy to be left out of account, on the basis of 60V of working voltage. When railway or subway break down during the service of a subway, 1,500 voltage approximating to line voltage flows through the load terminal of the drainage (rail and underground conduit) though momentary in the worst case. And so, an accident followed by dielectric breakdown, fire and damage by a fire is expected. Therefore, I suggest that insulation coordination should be considered against such a thing on designing, producing and setting up forced drainage.

  • PDF

A Study on the Reduction Method and the Analysis of VCB Switching Surge for High Voltage Induction Motor (고압전동식용 진단차식기의 스위칭써지 해석 및 연구)

  • 이은웅;김종겸;김택수;이성철
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.5
    • /
    • pp.761-769
    • /
    • 1994
  • VCB (Vacuum Circuit Breaker), with the strong arc extinction capability in switching the source of an induction motor, occurs the severe switching surge voltage which can cause the breakdown or the deterioration of motor insulation. Therefore, a method which reduces surge voltage across motor windings is necessary. So, it is analyzed that fast-rise-time surges resulting from VCB switching operations give rise to severe voltage stress on turn insulation. Additionally, the switching surge simulation algorithms using EMTP are developed, and C, R values of surge suppressor minimizing the steep-fronted stress in winding insulation surges are calculated.

Leg-Balancing Control of the DC-link Voltage for Modular Multilevel Converters

  • Du, Sixing;Liu, Jinjun;Lin, Jiliang
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.739-747
    • /
    • 2012
  • This paper applies carrier phase shifted pulse-width modulation (CPS-PWM) to transformerless modular multilevel converters (MMC) to improve the output spectrum. Because the MMC topology is characterized by the double-star connection of six legs consisting of cascaded modular chopper cells with floating capacitors, the balance control of the DC-link capacitor voltage is essential for safe operation. This paper presents a leg-balancing control strategy to achieve DC-link voltage balance under all operating conditions. This strategy based on circulating current decoupling control focused on DC-link balancing between the upper and lower legs in each phase pair by considering the six legs as three independent phase-pairs. Experiments are implemented on a 100-V 3-kVA downscaled prototype. The experimental results show that the proposed leg-balancing control is both effective and practical.