• 제목/요약/키워드: Insulation voltage

검색결과 1,016건 처리시간 0.021초

IGBT 인버터 구동 저압 유도전동기의 절연특성 연구 (A Study on the Insulation Characteristics of Low-Voltage Induction Motor driven by IGBT PWM Inverter)

  • 황돈하;박도영;김용주;구자윤;박태익;김진홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.206-210
    • /
    • 1999
  • Since the introduction of IGBT PWM inverters, many low-voltage induction motors have been driven by them. Recently, the stator winding insulation failures have attracted much concern due to high dv/dt of IGBT inverter output. In this paper, presented are the detailed insulation test results of 26 low-voltage induction motors. Six different types of insulation techniques are applied to 26 motors. The tests include PD, $tan{\delta}$, and DIV tests. Also, break-down tests by high voltage pulses are performed.

  • PDF

절연진단 데이타베이스 프로그램을 이용한 고압전동기 열화 분석 (Deterioration Analysis for High Voltage Motor Using Insulation Diagnostic Database Program)

  • 공태식;김희동;이영준;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.100-102
    • /
    • 2005
  • This paper is purpose to introduce the database management program of insulation tests for high voltage rotating machines. KEPRI has carried out insulation tests for high voltage equipment since 1998, the number of tests grow larger every year. It is difficult to manage the numerous test results, so we developed the insulation diagnostic database program. The features of this program are an easy-search test result and making a graph of AC, tan${\Delta}$ test. the most useful function is the trend management. Using the trend function, we can find the aging deterioration for high voltage machines easily.

  • PDF

GIS 절연 신뢰성 향상을 위한 탱크 내면 코팅이 파티클 거동에 미치는 영향 (Effect of the Inner Side Dielectric Coating of the Tank on the Particle Movement for Improving of GIS Insulation Reliability)

  • 이방욱;구자윤;김민규;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.267-269
    • /
    • 1996
  • In this work, the influence of wire type conducting particles on the insulation reliability of GIS has been systematically investigated when outer electrode was dielectric coated by epoxy resin. For this purpose, coaxial cylinder-type electrode was adopted in 362 kV chamber and various size of Cu conducting particle was used and different gas pressure was applied. To prove the coating effect on the gas insulation, different thickness of epoxy coated outer electrode have been considered and the lift-off voltage and flashover voltage have been analyzed. The results show that the dielectric coated electrode has an remarkable influence on the reducing particle behavior in GIS system and enhancing the GIS insulation reliability.

  • PDF

고압유도전동기 절연특성시험의 신뢰도 평가 (Evaluation of Insulation Diagnostic Test Reliability for Stator Winding of High Voltage Induction Motor)

  • 이광호;김현일;곽희진;오봉근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1838-1841
    • /
    • 2004
  • This test was performed to assess the correlation between insulation diagnostic tests and breakdown voltage strength of the stator winding of 6.6kV class induction motor in insulation deterioration condition which have been in service for 5 years after being installed in 1998. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor(${\triangle}tan{\delta}$), maximum partial discharges(Qmax) and AC breakdown test. we evaluated the correlation between insulation diagnostic test and AC breakdown test for stator winding of high voltage induction motor.

  • PDF

백화현상이 나타난 고압전동기 고정자권선의 절연특성 연구 (A Study on Insulation Property of White Powder Found on High Voltage Motor Stator Winding)

  • 공태식;김희동;이상길;김경열;주영호
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1627-1631
    • /
    • 2011
  • During a routine inspection of a large pump motor at power plant, white powder was found on the surface of the stator end windings. Visual inspection and high voltage insulation diagnosis was performed to determine whether this motor is available. The purpose of this paper is to understand the insulation properties of white powder found on high voltage stator and to know prevention of insulation weakness.

견인전동기 고정자 권선의 절연진단 특성 (Characteristics of Insulation Diagnostic in Traction Motor Stator Windings)

  • 김희동;김충효;박영;박현준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.336-338
    • /
    • 2006
  • Diagnostic tests are used to evaluate the insulation condition of stator windings in traction motor. These tests included ac current, tan delta and maximum partial discharge. The insulation condition of stator windings was assessed by three test items. The stator windings of traction motor were m good condition. After completing the diagnostic tests, the stator windings of traction motors were subjected to gradually increasing ac voltage, until the insulation punctured. No.5 stator windings failed near rated voltage of 18.9 kV. The breakdown voltage of No.1 stator windings was 13.0. The failure was located m a line-end coil at the exit from the core slot.

  • PDF

고압유도전동기 절연특성시험의 신뢰도 평가 (Evaluation of Insulation Diagnostic Test Reliability for Stator Winding of High Voltage Induction Motor)

  • 이광호;김현일;곽희진;오봉근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.46-49
    • /
    • 2004
  • This test was performed to assess the correlation between insulation diagnostic tests and breakdown voltage strength of the stator winding of 6.6kV class induction motor in insulation deterioration condition which have been in service for 5 years after being installed in 1998. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor(${\Delta}tan{\delta}$). maximum partial discharges(Qmax) and AC breakdown test. we evaluated the correlation between insulation diagnostic test and AC breakdown test for stator winding of high voltage induction motor.

  • PDF

154 kV급 고온초전도 변압기의 중성선용 60 kV 부싱의 기초 절연설계 (The Basic Insulation Design of 60 kV Bushing for Netural Line of 154 kV Class HTS Transformer)

  • 최재형;최진욱;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권3호
    • /
    • pp.32-35
    • /
    • 2008
  • A common problem in many fields of cryogenic power engineering is applying high voltage to cold parts of superconducting apparatus. In many cases, a bushing provides electrical insulation for the conductor which makes the transition from ambient temperature to the cold environment. The 60 kV class cryogenic high voltage bushing for neutral line of the 154 kV / 100MVA high temperature superconducting (HTS) transformer was described. The bushing is energized with the line-to-ground voltage between the coaxial center and outer surrounding conductors; in the axial direction, there was a temperature difference from ambient to about 77 K. For the insulation design of cryogenic bushing, electrical insulation characteristics of the GFRP were discussed in this paper.

IGBT PWM 인버터 구동 유도전동기의 절연성능 향상기술 연구 (A Study on the Insulation Performance Improvement of Induction Motors Fed by IGBT PWM Inverter)

  • 황돈하;박도영;김용주;이영훈;김동희;이인우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.335-339
    • /
    • 2001
  • The recent advancements in power electronic switching devices have enabled high frequency switching operation and have improved the performance of pulse-width modulated (PWM) inverters for driving induction motors. But, the insulation failures of stator winding have attracted much concern due to high dv/dt of IGBT PWM inverter. In this paper, the test results for evaluation on the stator winding insulation of low-voltage induction motors for IGBT PWM inverter applications are presented. The insulation characteristics are analyzed with partial discharge and dissipation factor tests. Also, insulation breakdown tests by switching pulse voltage are performed. An effective insulation technique to enhance the insulation strength is suggested from the test results.

  • PDF

Impulse Breakdown Behaviors of Dry Air as an Alternative Insulation Gas for SF6

  • Li, Feng;Yoo, Yang-Woo;Kim, Dong-Kyu;Lee, Bok-Hee
    • 조명전기설비학회논문지
    • /
    • 제25권3호
    • /
    • pp.24-32
    • /
    • 2011
  • [ $SF_6$ ]gas, which has an excellent dielectric strength and interruption performance, is used in various applications such as gas insulated switchgear (GIS) in substations. However, since $SF_6$ has a high global warming potential (GWP), it is necessary to find an eco-friendly alternative insulation gas. In order to examine the possibility of using alternative insulation gases for $SF_6$ in power distribution system equipment, the dielectric strength and physical phenomena of dry air in a quasi-uniform electric field are investigated experimentally in this paper. As a result, the breakdown voltages for positive polarity are higher than those for negative polarity under impulse voltage applications. The negative 50[%] flashover voltage, $V_{50}$ of dry air under conditions above 0.4[MPa] gas pressure, is higher than 150[kV], that is the basic impulse insulation level of distribution equipment. The $V_{50}$ increases linearly with increasing the gas pressure, regardless of the waveform and polarity of the applied impulse voltages. The voltage-time curves are dependent on the rise time of the impulse voltage and gas pressure. Furthermore, streamer discharge was observed through light emission images by an ICCD camera under impulse voltage applications.