• 제목/요약/키워드: Insulation standard

검색결과 309건 처리시간 0.032초

에너지 성능 기반의 기계설비배관 단열기준 개선을 위한 연구 (The Study to Improve the Insulation Standards for Mechanical Pipes based on Energy Performance)

  • 윤희원;류형규
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.28-35
    • /
    • 2021
  • The need for zero-energy building is increasing as a means of actively responding to climate change. Since pipe insulation is a factor that minimizes heat loss of cooling and heating facilities, it is necessary to check pipe insulation standards and prepare improvement plans of preparation for certification of zero energy buildings. In this study, domestic pipe insulation standards were checked to prepare new insulation standards based on energy performance. Through the development of a pipe insulation calculation program, the heat loss according to the insulation thickness of the piping for mechanical facilities was compared and reviewed. As a result, applying the insulation thickness of the KCS standard for the same conditions increased the heat loss by an average of 10% compared to the ASHRAE standard. For this reason, it is necessary to revise the pipe insulation thickness standard in consideration of heat loss due to thermal conductivity and pipe insulation thickness. Using the program in this paper, it is possible to design pipe insulation based on energy performance and help to determine the standard for pipe insulation thickness.

건물 냉난방수배관의 단열성능 향상을 위한 기준 연구 (A Standard Study for Improving Thermal Performance of the Hot and Cold Water Pipe Insulation in Buildings)

  • 최승혁;김유승;윤희원;류형규
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.21-30
    • /
    • 2017
  • Recently, It has increased the importance of building energy saving. Pipe insulation as well as building envelope insulation is to improve energy efficiency and reduce the energy loss. However, there continues to use the old standard for pipe insulation that is one of the most important elements in energy savings in buildings. The purpose of this study is to propose suitable pipe insulation thickness for reducing building energy use. The study also reviews pipe insulation thickness standard in accordance to Korea standard, ASHRAE 90.1 and BS5422 and analyzed through thermal simulation. As a result, it is necessary to apply the performance design method of the pipe insulation thickness to reduce the energy loss of the piping.

바닥충격음 차단성능 기준설정 고찰 (A Consideration on the Establishment of Standard level for Floor Impact Sound Insulation)

  • 송민정;기노갑;장길수;김흥식;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.226-229
    • /
    • 2001
  • Recently the impact sound insulation performance is regarded as one of the most import factors in determining the quality of housing environment. In order to reduce the impact sound level transmitted through the floors and structures, establishing the standard level of impact sound insulation performance is needed. In this consideration, The effecting facts for the standard insulation level is reviewed.

  • PDF

설비용 단열재 난연성 평가 현황과 개선 방안 (A Study on Incombustibility of Building Service System Insulation Material)

  • 박종일;김석현;홍진관;이민우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.999-1005
    • /
    • 2006
  • The aim of this paper is to evaluation survey and improvement method of building service system insulation material incombustibility. In Korea, various insulation materials are being used to prevent energy losses. Performance of insulation materials is gradually advanced, and new insulation materials are developed and being used. We don't have prefer test standard of insulation material incombustibility. In this paper we investigate domestic and foreign standard about incombustibility Through the authors will show how we can improve incombustibility test standard in Korea.

  • PDF

국내 건물 단열기준에 따른 냉.난방 부하 분석 및 최적 단열기준에 관한 고찰 (An Analysis of Thermal Loads Depending on Korea Building Insulation Standard and the Optimum Insulation Standard)

  • 서성모;박진철;이언구
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.146-155
    • /
    • 2011
  • Sustainable building is getting more and more important topic in 21C. Following this trend, building energy saving standard has been reinforced in Korea. Especially, insulation standards are revised continuously after1979. This study aims to evaluate the correlation between the revised insulation standards and heating and cooling loads of a residential building. This study shows that the standard of insulation is more related with heating load than cooling load, and cooling load is more related with other sources such as glass types and solar incidence through windows. In case of highly-insulated building such Passive Houses or Zero Energy Houses, the cooling load should also be considered as important as heating load when revising the building energy saving regulations in the future.

친환경자동차의 전기안전을 위한 절연저항 측정에 관한 연구 (A Study on the Insulation Resistance Measurement Technique for Electrical Safety of Green Car)

  • 이기연;김동욱;김향곤;문현욱
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.597-601
    • /
    • 2009
  • Green car such as a hybrid electrical vehicle and fuel cell vehicle is developed as a commercial target. UN/ECE/WP29 is developing GTR of HFCV and establishing the regulation and standard of electrical safety by ELSA. The regulation and standard about Electrical safety of vehicle are prescribed in ISO, UN/ECE, FMVSS, Japanese Attachment and so on, in case of insulation resistance is referred to keep more than 100/Vdc, 500/Vac. However, accurate method to measure insulation resistance agreeable to structure of vehicle does not exist now, it is actually that correctness of measurement drops according to the feature of battery and fuel cell stack. In this paper, the method to measure insulation resistance for protection against electrical shock by direct contact or indirect contact in Green Car will be indicated by making a comparison between the insulation measurement in standard of electrical safety and the experiment results for HEV and HFCV.

Insulation Saving Effect for Korean Apartment House Using Cross-Laminated Timber (CLT)

  • Pang, Sung-Jun;Lee, Bumjin;Jeong, Gi Young
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권6호
    • /
    • pp.846-856
    • /
    • 2017
  • The aim of this study was to develop the details of cross-laminated timber (CLT) envelops for satisfying the design standard for energy saving (DSEA) and passive standard in South Korea. When the same thickness of 180 mm concrete or CLT was used and the same materials for other layers were used for the roof, wall, and interlayer floor, the required insulation thickness for the different building envelopes in central, southern, and Jeju island was evaluated. As a result, compared to the concrete envelop, about 43 mm of insulation thickness was reduced for wall and roof with the CLT envelope. When the CLT envelopes were modified to protect the CLT from moisture based on FPInnovations (2011), the insulation thickness was further reduced by 12 mm. When the modified CLT building envelops satisfied with a passive standard are used for 10-story building, the required insulation was decreased by $40.89m^3$ for a floor ($105.27m^2{\times}2.3m$ in height) compared to concrete building. As the number of floors increases, about 3.58 m3 of insulation per floor was additionally saved.

공동주택 층간단열 완충재의 열에너지 특성의 관한 연구 (A Study on the Evaluation for Energy Characteristic of Absorber Floor Insulation of Apartment House)

  • 최동혁;최경석;강재식;이승언;조우진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.712-717
    • /
    • 2009
  • Ondol is a tradtional Korea heating system with a long history. The ondol heating system is a default in ordinary houses and high-rise apartment alike. But Intensified Architecture Law insulation standard can't satisfied standard insulation only light weight concrete in ondol. The between light weight concrete and slab apply EPS insulation is construct for generate a method of construction. The standard insulation for floor heating system is responsible but complicate construction thermal transmittance and absorber, deteriorate the cost and decreasing the performance insulation & impact floor sound. In study on the evaluation decrease heating-load of floor construction of the insulation & absorber that improvement floor a Apartment house.

  • PDF

한국표준원전 원자로용기의 단열 설계에 관한 연구 (A Study on the Insulation Design Parameters of the Reactor in the Korean Standard Nuclear Power Plant)

  • 김석범;백세진;임덕재;최해윤;이상섭;박종호
    • 에너지공학
    • /
    • 제8권2호
    • /
    • pp.285-292
    • /
    • 1999
  • 한국표준원전의 원자로용기 단열재 설치시 설계인자에 대한 수치해석적 연구를 전산 유체유동 코드인 FLUENT를 이용하여 해석하였다. 단열재 두께 및 원자로용기 벽과 단열재의 내부표면간의 공간간격에 대한 인자에 대해서 연구를 수행했다. 또한 단열재 설치시 단열재판넬 사이의 틈새 간격 때문에 발생하는 chimney effect으로 인한 단열재의 성능저하를 평가하였다. 수치해석 결과 최적의 공간 간격 및 단열재 두께를 얻을 수 있었다.

  • PDF

바닥충격음 차단성능 평가방법의 KS 규격화 방안 (Korean Industrial Standard of “Rating of floor impact sound insulation for impact source in building and of building elements”)

  • 송민정;장길수;김흥식;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.383-386
    • /
    • 2001
  • The KS of “Measurements of impact sound insulation of floors” was established before the years. But the KS of “Rating of floor impact sound insulation for impact source in building and of building elements” is not founded yet. To establish the rating measurement of floor impact sound insulation. The studies on the rating method of domestic floor system of impact sound insulation and response of its inhabitant’s were reviewed. And the rating method of ISO’s and JIS’s were studied in this consideration. The result of this study, KS of “Rating of floor impact sound insulation for impact source in building and of building elements” is proposed.

  • PDF