• Title/Summary/Keyword: Insulation property

Search Result 272, Processing Time 0.035 seconds

The preparation and characteristics of (Ba,Sr,Mg) $TiO_3$ ceramic for BL capacitor ((Ba,Sr,Mg)$TiO_3$를 이용한 입계층 캐패시터의 제작 및 유전특성에 관한 연구)

  • 오재유;오의균;강도원;김범진;박태곤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.251-254
    • /
    • 1998
  • The ($0.8BaTiO_3-0.1SrTiO_3-0.1MgTiO_3$)+$0.006Nb_2O_5$ ceramics were fabricated by conventional ceramic process. The dielectric property of specimen was investigated that the specimen was sintering temperature at 1,300C for 3hours and then annealed at $1,100^{\circ}C$ for 3hours in a atmosphere (air) to be painted on the surface with CuO paste. The results of the temperature and frequency are varied, the dielectric constant and loss tangent are unsuitable for BL capacitor. The dielectric constants were varied to be negative temperature coefficient(2.000-3,000) in the temperature range between -10 and $140^{\circ}C$, the dissipation factors (tan $\delta$) were some high(0.1-0.3). It was not grain insulation, in cause of the some difficult to be annealed temperature with CuO paste and fired atmosphere. But, we have some different annealing temperature and fired atmosphere, it will be suitable BL(Boundary Layer)capacitor.

  • PDF

Partial Discharge Quality Measurement improvement of XLPE Cable of 154kV by new method of FSA (박 센서 배열에 따른 154kV XLPE 케이블의 부분방전 검출 특성 연구)

  • Shin, Dong-Hoon;Yang, Jong-Seok;Lwin, Kyaw-Soe;Lim, Jong-Cheon;Hwang, Doo-Hyun;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.158-159
    • /
    • 2006
  • The system measuring the Partial discharge(PD) is very essential to investigate the hazard defects in the insulation systems of the high voltage engineering. We included two parts in this discussion; The proposed method of Foil Sensor Array and the normally used method m the practice. Firstly, it will be shown the improved sensitivity of our proposed FSA sensor compare with the existing normal foil sensor. And then, the linearity of detecting sensitivities of various kinds of FSA sensors such as $2{\times}2$, $2{\times}4$, $3{\times}3$ etc. using in our experiments, was shown. From the obtained results, we can see that FSA sensor is more sensitivity than normal foil sensor and the linear increment property of FSA sensitivities.

  • PDF

Analysis on Electrical Tree Growth Characteristics in XLPE According to Crosslinked Degree (XLPE의 가교도 분포에 따른 전기트리 진전 특성 분석)

  • Kim, Sang-Ki;Kim, Dcuk-Keun;Lee, Jeong-Bin;Lee, Jin;Kim, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.901-903
    • /
    • 1998
  • Crosslinked Degree is an important factor to determine dielectric property of crosslinked polyethylene(XLPE) used for the insulation material in power cables. Recently, though it is necessary to investigate electrical properties according to crosslinked degree as a part of the whole characterization of cable. it is not examined closely. In this study, crosslinked degree of samples were measured according to temperature and holding time of crosslinking, electrical tree characteristics of these samples were analyzed by crosslinked degree and applied temperature that was changed from normal temperature to operating temperature of power cables. As a result. when the crosslinked degree was low, dielectric properties were decreased and influence of temperature was increased. but the crosslinked degrees were high. initiation voltages of treeing were increased and dielectric properties were improved. It is proved that the optimum. crosslinked degree was one of most important factor for aging time and residual lifetime of power cable.

  • PDF

An Experiment Study for Flame Spread Prevention System of Snadwich Panels (샌드위치 패널의 화재확대 방지시스템 개발을 위한 실험적 연구)

  • Shin, Hyun-Joon;In, Ki-Ho;Yoo, Yong-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.6
    • /
    • pp.307-312
    • /
    • 2015
  • The sandwich panel is commonly used domestically because it's less costly and easier to handle. But fires have frequently occurred in buildings employing sandwich panels, such as the fires in Eecheon cold storage and in Gwangju Pyungdong industrial zone. Sandwich panels with steel plates on their surface prevent fire water from penetrating to the fire source, which makes it difficult to extinguish a fire in a timely manner. Toxic gas generated from some insulation material leads to serious loss of life and property. This study is intended to develop an extinguishing system for sandwich panels, thereby reducing the fire risk. Fire water and volume were determined in the wake of the study on the structure of a sandwich panel extinguishing system, and improvement and testing of the fire characteristics of the sandwich panel. Based on such study and test, a fire model test was conducted. Consequently, the sandwich panel with extinguishing system was proven to have a reduced fire risk, compared to traditional or fire retardant panels.

The Study of Fluoride Film Properties for Thin Film Transistor Gate Insulator Application (박막트랜지스터 게이트 절연막 응용을 위한 불화막 특성연구)

  • Kim, Do-Yeong;Choe, Seok-Won;An, Byeong-Jae;Lee, Jun-Sin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.12
    • /
    • pp.755-760
    • /
    • 1999
  • Various fluoride films were investigated for a gate insulator of thin film transistor application. Conventional oxide containing materials like $SiO_2\;Ta_2O_5\; and \; Al_2O_3$ exhibited high interface states which lead to an increased threshold voltage and poor stability of TFT. In this paper, we investigated gate insulators using a binary matrix system of fluoride such as $CaF_2,\; SrF_2\; MgF_2,\; and\; BaF_2$. These materials exhibited an improvement in lattice mismatch, interface state and electrical stability. MIM and MIS devices were employed for an electrical characterization and structural property examination. Among the various fluoride materials, $CaF_2$ film showed an excellent lattice mismatch of 5%, breakdown electric field higher than 1.2MV/cm and leakage current density of $10^{-7}A/cm^2$. MIS diode having $Ca_2$ film as an insulation layer exhibited the interface states as low as $1.58\times10^{11}cm^{-2}eV^{-1}$. This paper probes a possibility of new gate insulator materials for TFT applications.

  • PDF

Improvement on Surface Properties of Engineering Plastic with Adding Micro-$Al_2O_3$, Nano-$Al(OH)_3$ (Micro-$Al_2O_3$와 Nano-$Al(OH)_3$ 첨가에 따른 엔지니어링 플라스틱의 표면특성 개선)

  • Jung, Eui-Hwan;Lee, Han-Ju;Lim, Kee-Joe;Heo, Jun;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.29-29
    • /
    • 2010
  • Surface contamination and leakage current have caused operating problems. A flashover in a substation may result in destruction of an insulator or many others electrical equipment. Engineering plastics have good characteristic (light weight, good productivity and little of void) as compare with epoxy or porcelain insulators. Outdoor insulator must have resistance to contamination. However, it isn't suited to outdoor insulator because it is not hydrophobic. RTV(Room temperature vulcanizing) has a good property of hydrophobic and micro-filler. nano-filler have characteristics of obstructing exothermic reaction. In order to reduce the incidence of insulator flashover and damage, the silicon rubber contained with micro, nano-filler coating on surface of engineering plastics. In this paper, it compares tracking resistance, leakage current of the engineering plastic coated RTV with that of non-coated engineering plastic. And filled-composites performed much better than non-filled composites.

  • PDF

The effect of dynamic property of absorbing sheet on the amplification of heavy weight floor impact noise (완충재의 동특성에 따른 중량충격음 증폭에 관한 해석적 연구)

  • Hwang, J.S.;Moon, D.H.;Park, H.G.;Hong, S.G.;Hong, Geon-Ho;Lim, J.H.;Kim, Y.N.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.527-528
    • /
    • 2010
  • Previous experimental results performed by many researchers for a couple of decades in South Korea have shown that an absorbing sheet inserted in a conventional floating slab system for thermal insulation or vibration absorption may amplify the vibration of the slab system at specific frequency ranges depending on the material properties of the sheet. The amplified vibration, consequently, results in the heavy weight floor impact noise exceeding the sound level limit for an apartment house, 50dB. In this study, the amplification mechanism is examined through numerical analysis and a new slab system is proposed to reduce the amplification and control the noise. The new slab system consists of studs connecting the base slab and upper concrete finishing yielding the dramatically increased stiffness of the slab. The numerical simulation is performed to investigate the effect of the slab system with studs on the vibration and noise control. The results show that the performance of the slab is sensitive to the number and location of studs, and the heavy weight floor impact noise can be reduced up to 6-7dB compared to the conventional slab system at the optimal stud location.

  • PDF

Finite Element Analysis of Adiabatic Properties for the Wall System in Wood Frame House (유한요소법을 이용한 벽체의 단열 성능 분석)

  • Shim, Kug-Bo;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.48-57
    • /
    • 1995
  • 본 연구에서는 경골 목조 주택 (2${\times}$4 주택, 2${\times}$6 주택), 통나무 주택 및 콘크리트 주택(내단열, 중단열, 외단열) 벽체에 대하여 유한 요소 해석으로 단열 성능을 평가하였고, 표면 결로 현상을 분석하여 다음과 같은 결론을 얻었다. 1. 벽체의 단열 성능은 정량 골조 2${\times}$6를 사용한 주택이 가장 우수하였고, 경량 골조 2${\times}$4 주택, 통나무 주택, 콘크리트 주택의 순으로 감소하는 것으로 나타났다. 2. 콘크리트 벽체의 내단열, 중단열, 외단열의 벽체 구성법에 따른 단열 성능의 차이는 없었으며, 콘크리트 주택에서 단열재의 사용이 필수적이었다. 3. 내부 결로의 경우 콘크리트 벽체의 외단열이 가장 우수한 결로 예방성을 보였다. 이는 외부에 설치된 단열층이 외부의 낮은 온도를 차단해 벽체 전체의 온도를 높게 유지하기 때문이었다. 표면 결로는 모든 벽체에서 나타나지 않았지만, 실내 습도가 높아진다면 콘크리트 주택의 벽체에서 발생할 가능성이 가장 높았다. 본 연구는 벽체내의 단열 성능에 관하여만 분석을 하였고, 열전달 외에 축열성능 등에 관한 고려는 하지 않았으므로 추후에는 여러 가지 복합적인 열적 성능에 관한 연구가 수행되어야 하리라고 생각한다.

  • PDF

A Study on FSA Application and Standardization for Partial Discharge Measurement of 154 kV XLPE Cable (154 kV XLPE 전력케이블의 부분방전 측정을 위한 FSA의 적용 및 표준화 연구)

  • Shin, Dong-Hoon;Lwin, Kyawsoe;Yang, Jong-Seok;Hwang, Doo-Hyun;Lim, Jong-Chun;Park, Noh-Joon;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.5
    • /
    • pp.462-466
    • /
    • 2007
  • The measuring system of the Partial discharge(PD) is very essential to investigate the hazard defects in the insulation systems of the high voltage engineering. We will discussed this research which has included two parts. The proposed method of Foil Sensor Array(FSA) and the normally used method in the practice. Firstly, it will be shown the improved sensitivity of a FSA sensor, which is our aim, compare with the existing normal foil sensor. And then, the linearity of detecting sensitivities of various kinds of FSA sensors was shown. According to our experiments, we can see that FSA sensor is more sensitivity than normal foil sensor and the linear increment property of FSA sensitivities.

Thermal Comfort and Tactile Wearing Performance of Wool/nylon Fabrics for Tra-biz Garment (울/나일론 tra-biz 의류용 직물 소재의 열적 쾌적성과 착용특성)

  • Kim, Hyun Ah
    • Fashion & Textile Research Journal
    • /
    • v.18 no.6
    • /
    • pp.878-888
    • /
    • 2016
  • In this study, wool/nylon(50/50%) blend yarn and its fabrics for tra-biz(complex word of travel+business) garment were prepared, and its wear comfort characteristics were investigated through thermal manikin and human-body wearing experiment. In addition, tactile wearing performance from fabric mechanical properties and the dimensional stability and the pilling of the fabric specimen during wearing and dry-cleaning were measured and compared with those of wool 100% fabric specimen. Heat keepability of the wool/nylon(50/50%) blend fabric by thermal manikin experiment was superior than that of wool 100% fabric, this result was verified with human-body wearing experiment and its result coincided well with this experimental result. Tactile wearing performance of the wool/nylon(50/50%) fabric from fabric mechanical properties measured by FAST system was better than that of the wool 100% fabric. The dimensional stability of the wool/nylon(50/50%) fabric was more stable than that of the wool 100% fabric. Because relaxation shrinkage was lower and hygral expansion of wool 100% fabric was more high. However, the breathability and pilling property of the wool/nylon(50/50%) fabric were inferior than those of the wool 100% fabric. The possibility of application for tra-biz garment of wool/nylon(50/50%) blend fabric was observed because of good heat keepability, tactile wearing performance and washing fastness.