• Title/Summary/Keyword: Insulation method

Search Result 1,174, Processing Time 0.028 seconds

A Study on Methodology for Verifying Energy Saving and Activity in School (학교 건물에서의 에너지절감 성과 활동 검증을 위한 방법론 연구)

  • Lee, Hangju;Kim, Insoo
    • Journal of Energy Engineering
    • /
    • v.29 no.1
    • /
    • pp.25-33
    • /
    • 2020
  • Recently, as the mandatory policy of zero energy building is promoted, policies / systems for transition to Zero Energy School are being promoted, but there is no method to systematically analyze and verify the results of energy saving activities for school buildings. For the study of energy performance verification methodology, the current status of related standards was referred to, and the case study of other methodologies was conducted to examine the tools that can analyze the performance in the field. In addition, this study analyzed the current status and characteristics of energy management through domestic school visits. In this paper, we presented various energy saving projects such as air conditioning and heating facilities, lighting, insulation, change operation behavior, and improve operation methods in new and existing school buildings, and M & V methods for verifying energy savings before and after implementation of energy conservation projects.

Strength Assessment of LNG CCS using Strength Analysis Method for Composite Materials (직교이방성 복합재료의 극저온 재료 물성치를 고려한 LNG CCS의 강도 평가에 관한 연구)

  • Jeong, Han Koo;Yang, Young Soon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.2
    • /
    • pp.114-121
    • /
    • 2014
  • Liquefied natural gas(LNG) cargo containment system(CCS) has the primary function of ensuring both adequate structural safety with respect to sloshing load which is defined as a violent behaviour of the liquid contents in CCS due to external forced motions and thermal insulation keeping natural gas below its boiling point. Among different LNG CCS types such as independent B-type and membrane ones, Mark III CCS is considered in this paper to perform its strength assessment. Mark III CCS plate is designed and constructed by stacking various non-metallic engineering materials such as plywood, triplex, reinforced PU foam that are supported by series of mastic upon inner steel hull structure. From the viewpoint of structural analysis, this plated structure is treated as a laminated composite structure showing complex structural behaviour under external load. Advanced finite element models of Mark III CCS plate is generated and used in conjunction with ultimate strength based failure criteria from laminated composite mechanics for the strength assessment. The strength assessment is performed within the initial failure state of Mark III CCS plate. Results provide failure details such as failure locations and loads. Finally obtained results are reviewed using the loads from acceptance criteria suggested by classification.

Development of Nano Ceramic Structures for HEPA Type Breathing Wall (HEPA Filter형 숨쉬는 벽체용 나노세라믹 여재개발)

  • Kim, Jong-Won;Ahn, Young-Chull;Kim, Gil-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.274-279
    • /
    • 2008
  • In the perspective of saving energy in buildings, high performance of insulation and air tightness for improving the heating and the cooling efficiency has brought the positive effect in an economical view. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and it is also very harmful to residents because they spend over 90% of their time in the indoor area. Therefore, the ventilation is important to keep indoor environment clean and it can also save energy consumption. In this study, a HEPA type breathing wall is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. To make fine porous structures, polymer nano fibers which were made by electro spinning method are used as a precursor. The nano fibers are coated with SiO2 nano particles and finally the HEPA type breathing wall is made by sintering in the electric furnace at $300\sim500^{\circ}C$. The pressure drops of nano ceramic structure are 8.2, 25.5 and 44.9 mmAq at the face velocity of 2.0, 5.9 and 8.8 cm/s, respectively. Also the water vapor permeability is $3.6g/m^2{\cdot}h{\cdot}mmHg$. In this research, the porous nano ceramic structures are obtained and the possibility for the usage of a material for HEPA type breathing wall can be obtained.

The Analysis of the Carbonization Properties between RCD Source Terminals Deteriorated by Tracking (누전차단기 외함 전원측 단자사이의 트래킹에 의한 탄화특성 분석)

  • 최충석;송길목;김동우
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.13-19
    • /
    • 2003
  • In this paper, we studied on the characteristics of RCD(Residual Current Device) case deteriorated by tracking, and compared the tracked samples between in the site of fire($S_1$) and in the reappearance experiment($E_1$). This experiment is applied to IEC Publ. 112 method. Electrical fire by tracking occurred after scintillation and dry-band generated. The insulation resistance between source terminals of RCD case was about 25.7Ω in $E_1$ and the resistance was about 58.6Ω in $S_1$.The exothermic peaks of $E_1$ appeared at $491.0^{\circ}C$ and $603.2^{\circ}C$. The exothermic peak at $603.2^{\circ}C$ was shown by tracking. And the exothermic peak of $S_1$ appeared at $593.1^{\circ}C$. In spectrum of $S_1$ and $E_1$, absorption peak didn't appear at near 1590 cm$^{-1}$ .

Fire Resistance Performance of High Strength Concrete Columns with Fireproof Gypsum Board (방화석고보드를 부착한 고강도 콘크리트 기둥의 내화성능)

  • Youm, Kwang-Soo;Jeon, Hyun-Gyu
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.2
    • /
    • pp.229-235
    • /
    • 2010
  • In this study, fire resistance performance of high strength concrete specimen with fireproof gypsum board was investigated for possible use in upgrading fire-resistant performance of the existing building and repair of fire damaged structures. Fire test of eight identical high strength concrete columns were carried out for 180 minutes in accordance with ISO-834. The temperature distributions in longitudinal reinforcement and concrete temperature at various depths were recorded. The fireproof performance of gypsum board and explosive spalling of concrete were observed. The specimens with 15 mm thick twoply fireproof gypsum board spalled after gypsum board crumbled regardless of fastening methods. However, when the thickness of fireproof gypsum board was more than 30 mm, it was possible to prevent the explosive spalling and control the rebar temperature. Although the effect of cover thickness could not be compared because the explosive spalling occurred, there seemed to be no difference in insulation efficiency.

Diagnosis of Insulation Deterioration in Cast Resin Transformer Using Method of AE Measurement (음향 방출 측정법을 이용한 몰드변압기 열화진단)

  • Lee, Sang-Woo;Gu, Kyung-Chul;Kim, Seung-Gyu;Kim, In-Sik;Lee, Dong-In;Kim, Ki-Chai;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1936-1938
    • /
    • 2000
  • In this paper, a frequency spectra of AE (acoustic emission) signals detected from the partial discharges of an epoxy resin void and a cast resin transformer in operating were analyzed to offer the proper frequency range of AE signals from the corona discharge for the purpose of AE sensor selection, From these results, a frequency spectra of AE signals emitted from the corona discharges in the void of an epoxy resin sample were about 190[kHz] to 220[kHz] by the FFT(fast fourier transform), A frequency spectra of AE signals emitted from a cast. resin transformer with non-load were appeared to be downward of about 140[kHz] by the FFT, and then a frequency spectra of AE signals emitted from the above of cast resin transformer with load were appeared to increase from about 190[kHz] to 220[kHz] by the FFT.

  • PDF

The R-V Characteristics of $SiO_2 $ & $SiO_2/TiN$ Thin Film Fabricated by RF Sputtering (RF Sputtering으로 제작한 $SiO_2 $$SiO_2/TiN$ 박막의 R-V 특성)

  • 김창석;하충기;김병인
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.826-832
    • /
    • 1998
  • In this study the thin films with the structure of Si+SiO$_2$+TiN are made by RF supttering method. TiN, which has small diffusion coefficient and low resistivity, is evaporated between SiO$_2$ and Al layers. It investigates the V-R characteristics depending on the thickness of SiO$_2$ which is used as insulation layer and researches its effects on voltage stability of thin film and varistor. These films show very small resistance valus in negative(-) voltage and large and large value in positive voltage band, and with the increase of voltage, resistance value is rapidly reduced and the satisfactory characteristic of varistor is shown at +1[V]. It is found that resistance value of TiN thin film is small and also TiN thin film has more current than the thin film which is not evaporated by TiN thin film. When Al electrode is evaporated of SiO$_2$ thin film, spiking occurs, but the spiking can be prevented with evaporation of TiN between SiO$_2$ and Al layers and this thin films in made easily because of its good attachment. With the increase of voltage, the resistance is changed into non-linear pattern and the bidirectional varistor characteristic is shown and then its theory can be verified by this experiment. Accordingly, when TiN is evaporated of Si Wafer(n-100), it obtains better voltage-resistance than thin film which is not evaporated and also when varistor character is used electrically to automatic control element such as elimination of flame, power distribution arrestor and constant voltage compensation, satisfactory reproducibilities are expected.

  • PDF

A Study on the Development of the Acoustic Absorption Well of the Cruise Yacht (크루즈요트의 기관실 소음 차단용 차음벽 개발에 관한 연구)

  • Yu, Young-Hun;Yi, Jong-Keun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.05a
    • /
    • pp.109-113
    • /
    • 2007
  • Yacht have an high powered main engine relatively light hull, so the noise generated from the engine have a bad influence upon the crew and passenger. Recently, cruise yacht is made an attempt by domestic production skill, however the insulation skill of the noise made by the main engine is not satisfy the real purchasing power of the buyer. Like this, yacht cabin's noise level is becoming the barometer to decide the purchase. the method to insufficient. However, if we use the skill of the monitoring equipment and the genetic algorithm system, the circumference of the main engine can be enclosed by an high quality absorbtion wall and the noise levels of the cabins are improved. In this study, the sound absorbtion barrier is experimentally researched by change the volume and the length of the neck for the Helmholtz resonator as the resonator can absorb the noise effectively.

  • PDF

Ultra-Precise Polishing of Mica Glass Ceramics Using MR Fluids and Nano Abrasives (MR fluid를 이용한 Mica Glass Ceramics의 초정밀 연마)

  • Beak, Si-Young;Song, Ki-Hyeok;Kim, Ki-Beom;Kim, Byung-Chan;Kang, Dong-Sung;Hong, Kwang-Pyo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.5
    • /
    • pp.85-90
    • /
    • 2017
  • Mica-glass ceramics has features such as micro-sized crystals, high strength, chemical resistance, semitransparent optical properties, etc. Due to its superior material properties, mica glass ceramics have increasing applications in dental and medical components, insulation boards, chemical devices, etc. In many applications, especially for dental and medical components, ultra-precise polishing is required. However, it is known to be a very difficult-to-grind material because of its high hardness and brittle properties. Thus, in this study, a newly developed ultra-precise polishing method is applied to obtain nano-level surface roughness of the mica glass ceramics using magnetorheological (MR) fluids and nano abrasives. Nano-sized ceria particles were used for the polishing of the mica glass ceramics. A series of experiments were performed under various polishing conditions, and the results were analyzed. A very fine surface roughness of Ra=6.127 nm could be obtained.

Optimum Method of Windows Remodeling of Existing Residential according to the Window Properties and Window Wall Ratio (창호의 성능 및 건물의 창면적비에 따른 기존 단독주택의 창호 리모델링 방안 연구)

  • Lee, Na-Eun;Ahn, Byung-Lip;Jeong, Hak-Geun;Kim, Jong-Hun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.71-78
    • /
    • 2013
  • A need for building energy efficiency is on the issue since energy demand in the building stock in Korea represents about 24% of the final energy consumption. As a way of improving the thermal performance of buildings for reducing maintenance costs and environmental conservation, a lot of effort is shown to improve the building energy efficiency by applying improvement of envelope insulation performance for buildings whose energy efficiency is low relatively through the remodeling. The windows of building envelopes are areas that lead to the biggest heat loss in the building. So windows are considered to be the primary target of energy efficiency in remodeling and various studies for windows have been done. Currently, however, only U-factor and airtightness of windows performance are regulated. Window wall ratio(WWR) and solar heat gain coefficient(SHGC) of windows are not considered when conducting the remodeling. In this study appropriate performance of windows(U-factor and SHGC) for existing residential is proposed according to the window wall ratio by using EnergyPlus. As the results of this study, the U-factor of windows representing the maximum energy savings is $1.0W/m^2K$ but in case of SHGC, the values that indicate the maximum energy savings are different depending on the window wall ratio. Therefore, when conducting the remodeling of windows, to determine energy efficiency by considering only the U-factor is inadequate so it is necessary that appropriate windows are applied to buildings by considering window wall ratio and windows properties(U-factor and SHGC).