Influence of Tank Inner Side Dielectric Coating on the Particle Behaviour and Flashover Voltage in SF\ulcorner Gas Insulated System

  • Lee, Bang-Wook;Koo, Ja-Yoon
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.3
    • /
    • pp.77-81
    • /
    • 1997
  • In his work, the influence of wire type conducting particles on the insulation reliability of GIS has been systematically investigated when the epoxy resin based dielectric coating was made on he inner side of outer electrode. For this purpose, coaxial cylinder-type electrode was adopted in 362 kV chamber and various sizes of Cu conducting particle were used under different gas pressures. In order to elucidate the coating effect on the gas insulation, different thickness of dielectric coating has been considered and then the lift-off voltage and flashover voltages have been measured. The results shown that the dielectric coating has a remarkable influence by restraining the movement of particle in GIS system, and thus GIS insulation reliability is noticeably improved.

  • PDF

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

Surface Discharge Characteristics Study on the Laminated Solid Insulator in Quasi-Uniform Electric Field with Dry Air

  • Min, Gyeong-Jun;Bae, Sungwoo;Kang, Byoung-Chil;Park, Won-Zoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.603-609
    • /
    • 2015
  • Dry air is an excellent alternative to $SF_6$ gas and is used as an insulation gas in Eco-friendly Gas Insulated Switchgears (EGISs), which has gained popularity in industry. Solid insulators in EGIS play an important role in electrical insulation. On the other hand, surface discharge can occur easily when solid insulators are used. This paper explored the surface discharge characteristics on the structure of three-layered laminated solid insulators to elevate the flashover voltage. A laminated solid insulator was inserted after the quasi-uniform electric field was formed in the test chamber. Dry air was then injected to set the internal pressure to 1 ~ 6 atm, and the AC voltage was applied. When identical solid insulators were stacked, the surface discharge characteristics were similar to those of a single solid insulator. On the other hand, the flashover voltage rose when the middle part was thicker and had lower permittivity than the top and bottom parts in the laminated solid insulator. Based on experimental results, when stacking a solid insulator in three layers, the middle part of the solid insulator should be at least four times as thick as the top and bottom parts and have lower permittivity than the others. In addition, the flashover voltage increased with increasing gas pressure on the surface of the laminated solid insulator due to the gas effect. This study may allow insulation design engineers to have useful information when using dry air for the insulation gas where the surface discharge can occur.

The Characteristics of Insulation with Temperature Variations of $SF_{6}$ ($SF_{6}$ 가스의 온도변화에 따른 절연특성)

  • 이광식;박광서;박경태;김이국;박창기
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.8
    • /
    • pp.354-358
    • /
    • 2003
  • In this paper, insulations characteristics by temperature changes(+50~-50[$^{\circ}C$]) of $SF_{6}$ gas in the experimental chamber were studied. From this result, at the low temperature, the breakdown voltage was increased with a drop of temperature and an increase of inner pressure in GIS. In addition the ability of insulation of liquid $SF_{6}$ was higher than that of the highly pressurized $SF_{6}$ gas. That is, with progress of low temperature, the main reason of breakdown was not liquefaction of $SF_{6}$ but rapid decrease of inner pressure. This study will come in greatly handy for the insulation design of GIS in a hard cold region

A Study on the heating conditions affect on the insulation characteristics of polyamid papers (가열조건이 폴리아미드지의 절연특성에 미치는 영향)

  • Sun, J.H.;Kim, W.S.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2047-2049
    • /
    • 2000
  • In this study, we describe comparison of insulation characteristics of polyamid papers with heating conditions. The partial discharge behavior until breakdown and breakdown strength for thermal degradation films are observed in $SF_6$ gas chamber. The four layered NOMEX films of thickness of 50${\mu}m$ were used as solid insulation films and the sphere of which diameter is 40mm to sphere electrode system was used and each insulation films were inserted between sphere electrodes. The used gas pressure was 1.0bar and used temperature was each of 250$^{\circ}C$, 270$^{\circ}C$, 300$^{\circ}C$, 320$^{\circ}C$, 350$^{\circ}C$ and the voltage were applied until breakdown films.

  • PDF

Effect of the Inner Side Dielectric Coating of the Tank on the Particle Movement for Improving of GIS Insulation Reliability (GIS 절연 신뢰성 향상을 위한 탱크 내면 코팅이 파티클 거동에 미치는 영향)

  • Lee, Bang-Wook;Koo, Ja-Yoon;Kim, Min-Kyu;Kim, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.267-269
    • /
    • 1996
  • In this work, the influence of wire type conducting particles on the insulation reliability of GIS has been systematically investigated when outer electrode was dielectric coated by epoxy resin. For this purpose, coaxial cylinder-type electrode was adopted in 362 kV chamber and various size of Cu conducting particle was used and different gas pressure was applied. To prove the coating effect on the gas insulation, different thickness of epoxy coated outer electrode have been considered and the lift-off voltage and flashover voltage have been analyzed. The results show that the dielectric coated electrode has an remarkable influence on the reducing particle behavior in GIS system and enhancing the GIS insulation reliability.

  • PDF

THE PARTICLE SIZE EFFECT ON COMBUSTION BEHAVIOR OF CELLULOSE INSULATION

  • Choi, Jeong-Hwa;Kim, Hong;Ryu, Kyong-Ok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.185-192
    • /
    • 1997
  • The combustion of cellulose insulation treated with Borax, Boric acid and Aluminum Sulfate as combustion retardants is examined by candle type combustion tester. The cellulose fibers in cellulose insulation are classified by diameter as less than 0.2mm, 0.2mm-0.5mm, 0.5mm-2mm and more than 2mm. The burning behavior of cellulose insulation are studied by LOI (Limit Oxygen Index: Beginning point of smoldering), L- point (Lower point of combustion transition from smoldering- flaming to flaming combustion), LOI, L-point and H-point rise with the increasing particle size of cellulose fibers because thermal decomposition rate of cellulose fiber decreases. The phenomena of combustion transition from smoldering to flaming combustion are determined by the generating rate of combustible gas and the formation rate of combustible gas mixture within the zone of cellulose fiber heated.

  • PDF

Experiment on the Polish Condition of Needle Electrode on the Insulation Properties of Gas Mixtures (침전극 가공상태에 따른 혼합가스의 절연특성에 관한 실험)

  • Go, Yeon-Seong;Yeo, Dong-Goo;Seo, Ho-Joon;Lee, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.339-340
    • /
    • 2006
  • AC spark discharge voltage of SF6/CO2and SF6/N2 containing various mixed rate in volume percent (1, 5 and 10%) of SF6 in non-uniform fields are investigated. The needle to plane electrode gap spacing was 5 and 10 mm, and the gas pressure was varied within the range of 0.1~0.7 MPa. We have observed a N-characteristic typical for the electronegative gases even in gas mixtures of 1% SF6 with CO2 and N2 as buffer gases. Especially, the materials of the needle electrode affect the insulation properties of the gas mixtures drastically. On the contrary to the case of needle electrodes made by mild steel or high carbon steel, the N-characteristics are hardly perceived in the case of stainless steel needle in this experiment.

  • PDF

A Study on the Manufacture of Gas Insulated Switchgear Spacer Using APG Molding Process (APG 주형방식을 이용한 가스절연개폐기용 절연 스페이서 제작에 관한 연구)

  • Lee, Chanyong;Bae, Jaesung;Cho, Han-Gu;Lee, Sangmook;Lee, Jaehyeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.4
    • /
    • pp.386-391
    • /
    • 2022
  • The gas insulation switchgear, which is a device for protecting a power system, cannot be supported by the insulation gas itself in a charge unit stored in a metal container. Therefore, molding technology is required to manufacture a gas insulation switch spacer. The APG method injection molding simulation was performed by applying the variables obtained through the physical properties of an epoxy composite used for manufacturing an insulating spacer to a moldflow software. After varying the temperature conditions of heater in the simulation, the thermal characteristics and the degree of hardening of the spacer were analyzed, based on which the optimum process conditions are presented.

Ablation Characteristic Study for Carbon Fabric/EPDM Chamber Insulation (Carbon Fabric을 삽입한 EPDM계 연소관 내열재 삭마 특성 연구)

  • Kim, Jin-Yong;Choi, Ji-Yong;Rho, Tae-Ho;Lee, Won-Bok;Cho, Won-Man;Hahm, Hee-Cheol;Yun, Nam-Gyun;Rhee, Young-Woo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.2
    • /
    • pp.73-79
    • /
    • 2012
  • We developed the carbon fabric/EPDM chamber insulation in order to protect motor case with high intensity gas flow. A six-inch simulation motor connected with extension tube was designed to test ablation characteristic of insulation. High intensity gas flow was induced by a FRP disc with hole between motor and extension tube. After ground test, ablation depth of the carbon fabric/EPDM insulation was decreased compared to another insulations after ground static test.