• 제목/요약/키워드: Insulation failure

검색결과 189건 처리시간 0.022초

Mechanical behavior test and analysis of HEH sandwich external wall panel

  • Wu, Xiangguo;Zhang, Xuesen;Tao, Xiaokun;Yang, Ming;Yu, Qun;Qiu, Faqiang
    • Advances in concrete construction
    • /
    • 제13권 2호
    • /
    • pp.153-162
    • /
    • 2022
  • Prefabricated exterior wall panel is the main non-load-bearing component of assembly building, which affects the comprehensive performance of thermal insulation and durability of the building. It is of great significance to develop new prefabricated exterior wall panel with durable and lightweight characteristics for the development of energy-saving and assembly building. In the prefabricated sandwich insulation hanging wall panel, the selection of material for the outer layer and the arrangement of the connector of the inner and outer wall layers affect the mechanical performance and durability of the wall panels. In this paper, high performance cement-based composites (HPFRC) are used in the outer layer of the new type wall panel. FRP bars are used as the interface connector. Through experiments and analysis, the influence of the arrangement of connectors on the mechanical behaviors of thin-walled composite wall panel and the panel with window openings under two working conditions are investigated. The failure modes and the role of connectors of thin-walled composite wallboard are analyzed. The influence of the thickness of the wall layer and their combination on the strain growth of the control section, the initial crack resistance, the ultimate bearing capacity and the deformation of the wall panels are analyzed. The research work provides a technical reference for the engineering design of the light-weight thin-walled and durable composite sandwich wall panel.

외부전극 헝광램프의 핀홀 현상 (Pinhole Phenomena in the External Electrode Fluorescent Lamps)

  • 길도현;김상범;송혁수;유동근;이상훈;박민순;강준길;조광섭;조미령;황명근;김영욱
    • 한국진공학회지
    • /
    • 제15권3호
    • /
    • pp.266-272
    • /
    • 2006
  • 외부전극 형광램프의 구동에서 과도한 전력을 인가하면, 외부전극 부분의 유리관 표면에 작은 원형의 구멍(핀홀)이 발생하여 램프가 파손된다. 핀홀은 외부전극과 유리관을 유전층으로 하는 캐패시터의 절연파괴이며, 이러한 절연파괴력은 인가되는 전력에 비례한다. 유전상수가 K인 램프에 흐르는 전류가 작을 때, 핀홀이 발생하는 유리관의 절연파괴 전기장의 세기는 약 3K kV/mm,이다. 이러한 절연파괴 전기장의 세기는 램프에 흐르는 전류가 커질수록 작아진다.

열저항 효과를 고려한 멤브레인식 LNG 저장탱크의 누설 안전성에 관한 연구 (On the Leakage Safety Analysis of Membrane LNG Storage Tank With Thermal Resistance Effects)

  • 김청균;조승현;서흥석;홍성호;이승림;김영규;권부길
    • 한국가스학회지
    • /
    • 제8권4호
    • /
    • pp.1-7
    • /
    • 2004
  • 본 연구에서는 멤브레인식 LNG 저장탱크의 누설 안전성을 목재와 PUF로 구성된 단열재 및 예응력 콘크리트(PC) 재질이 균일하다는 가정하에 열저항 평형온도 효과를 고려하여 유한요소법(FEM)으로 해석하였다. FEM 계산결과에 따르면, 목재와 PUF로 구성된 단열재 구조물은 누설 LNG에 의해 구조물 자체가 먼저 파손되므로 누설 안전성을 보장할 수 없다. 그러나, 내부탱크와 단열재가 동시에 파손되어도 외부탱크 PC 구조물은 강도 안전성을 확보하고 있으므로 누설 LNG를 최소 10일 정도는 안전하게 지연시킬 수 있어 멤브레인식 LNG 저장탱크 시스템의 누설 안전성은 확보될 수 있다.

  • PDF

복합화력발전의 가스연료 공급계통에 대한 위험도 평가 기법 연구 (I) : API RBI 절차에 기반한 위험도 평가 (Risk Assessment Technique for Gas Fuel Supply System of Combined Cycle Power Plants (I) : Based on API RBI Procedures)

  • 송정수;유종민;한승연;최정우;윤기봉
    • 에너지공학
    • /
    • 제27권2호
    • /
    • pp.1-13
    • /
    • 2018
  • 미세먼지 저감 및 에너지원 변환에 대한 정책 추진에 따라 천연가스를 연료로 하는 발전의 비중이 확대되고 있다. 복합화력발전 플랜트, 열병합발전 플랜트 등에서 천연가스 연료공급계통이 가스가 가열된 상태에서 고압으로 운용되고 있으므로, 누출사고를 예방하여 화재 및 폭발에 의해 사고를 방지하여야 한다. 본 연구에서는 API RP 581 RBI 코드를 기반으로 복합화력발전 플랜트의 천연가스 연료공급계통을 대상으로 위험도 평가를 수행하였다. API RBI 코드의 적용을 위해 평가 대상 계통의 라인 및 세그먼트를 구분하였다. 파손확률과 파손피해 산출을 위해 운전 데이터 및 입력 정보를 분석하였다. 설치 초기 시점 및 운전시간 경과에 따른 위험도 평가 결과 추이를 분석하였다. 코드 기반 평가 시 가스연료 공급계통은 두께 감육, 외부 손상, 기계적 피로 손상기구의 영향이 주로 반영되었다. 운전 시간이 경과함에 따라 단열재 하부 부식(CUI, Corrosion Under Insulation) 등에 의한 외부손상이 위험도를 상승시키는 원인으로 예상되었다.

전력용 변압기 경년열화와 관련된 DGA 대표가스에 관한 연구 (Representative Dissolved Gases indicating Aging of Power Transformers)

  • 권동진;김용현;주병수
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권1호
    • /
    • pp.23-28
    • /
    • 2017
  • The life management technology becomes important as the failure risk of the aged power transformers increases. Asset management technology, therefore, has been developed to evaluate the remaining life and build replacement strategies of power transformers, which enables an optimal investment decisions based on reliability and economic feasibility. The remaining life assessment technology uses data related to such as installation, operation, maintenance, refurbishment, and disposed history of power transformers. The optimal investment decision additionally uses data related to failure and social costs. To develop the asset management technology in power transformers, it is important to find deterioration parameters directly indicating degradation of power transformers. In this study, 110,000 DGA data during the past 35 years have been analyzed in order to find the deterioration parameters related to the degradation of power transformers. The alarm rates of combustible gases ($H_2$, $C_2H_2$, $C_2H_4$, $CH_4$, $C_2H_6$), TCG CO, and $CO_2$ were analyzed as deterioration parameters. The origin of the gas was discussed in connection with discharge, overheating and insulation aging.

XLPE 절연케이블의 열화진단 정확도 향상을 위한 VLF tanδ 판정기준 개선 (An Amendment of the VLF tanδ Criteria to Improve the Diagnostic Accuracy of the XLPE-insulated Power Cables)

  • 이재봉;정연하
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1644-1651
    • /
    • 2010
  • VLF $tan{\delta}$ diagnosis technology is introduced in IEEE Std 400 and proposed as evaluation criterion in an effective way of detecting water tree which mainly causes the failure of XLPE insulated cables. In order to inspect the accuracy of the VLF $tan{\delta}$ method for XLPE insulated power cables in Korean distribution system, diagnosis for 41 cables which were being serviced in the fields has been carried out and they were removed for AC breakdown voltage test after. Regarding the 41 cables, it was hard to confirm any relation between the VLF $tan{\delta}$ values and AC breakdown voltages and also water tree in the insulation was not detected. However, the other cables were failed several days after the diagnosis of the 41 cables. Water trees were found and their VLF $tan{\delta}$ values were also much higher than the criterion of IEEE standard. It has been ascertained that we need to change the IEEE criteria in order to improve the accuracy of detecting water trees by additional analyzing of field examples of failure and case studies from overseas countries and therefore amended VLF $tan{\delta}$ test voltage and evaluation criteria have been proposed.

지중송전케이블 종단접속함 종류에 따른 외기 및 운전온도에 의한 열특성 분석 (Thermal Characteristics Analysis by Ambient and Operating Temperature according to the Kinds of Terminations in Underground Power Cable Systems)

  • 정채균;강지원;이방욱
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1154-1160
    • /
    • 2015
  • This paper describes the thermal characteristics of underground power cable system terminations according to the change of ambient temperature as well as operating temperature. Recently, the failure has been gradually increasing in outdoor termination during winter season because the power demand was increased by electricity heating system. The power demand and outdoor temperature is difference between day time and night time. The temperature difference has an influence on conductor extension and shrinkage due to conductor force as well as thermal mechanical characteristics. These phenomena have daily repeated during heating and cooling period of conductors. In these cases, the insulation of outdoor terminations might be degraded by the reduced interface pressure surrounding stress relief cone. Therefore, in this paper, the thermal characteristics are variously analysed by simulation considering power demand and ambient temperature condition during winter season at epoxy type termination as well as slip-on type termination

2점절 차단기 균압용 콘덴서 절연파괴 고장 메커니즘 및 성능검증 방법에 관한 연구 (Study on the Performance Verification Method and Failure Mechanism of Grading Capacitor of a Two-break Circuit-breaker)

  • 오승열;한기선;김태균
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권1호
    • /
    • pp.11-15
    • /
    • 2019
  • 최근 송전전압 격상으로 인해 차단기 또한 정격이 높아지고 있다. 이에 차단부의 전압 정격을 높이기 위한 방법으로 차단부 2개 이상을 직렬로 구성하는 다점절 차단기가 설치되어 운용되고 있다. 다점절 차단기에서 차단부 극간에 설치되는 균압용 콘덴서는 점절간 균등한 전압분배와 초기 과도회복전압을 저감하는 기능을 수행한다. 하지만, 세계적으로 실계통 사용에서 균압용 콘덴서는 기계적인 손상, 절연파괴에 의한 폭발 등 다수의 고장이 발생하고 있어, 이에 대한 원인 규명과 새로운 성능 검증방법에 대한 연구 필요성이 제기 되고 있다. 본 논문에서는 한전 계통에서 주로 발생한 균압용 콘덴서의 절연파괴 원인을 규명하고 이에 대한 제품 성능검증 방법을 제안하고자 한다.

XLPE 절연체의 등가 및 가변온도 가속열화실험을 통한 기계적 특성 비교 분석 (A Comparison Study on Mechanical Properties of XLPE Insulation Thermally Degraded at Equivalent and Variable Temperature Conditions)

  • 김태준;황재상;정성훈;김태영
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.73-77
    • /
    • 2022
  • Recently, as the number of years of operation has increased for more than 30 years, interest in evaluating the remaining life of major power facilities such as transformers and ultra-high voltage cables is increasing. In particular, the risk of failure is increasing because the underground transmission XLPE cable has been built since 1980 and has been operating in excess of 30 years of design life or close proximity. Therefore, it is necessary to develop an algorithm to evaluate the residual life of the XLPE cable considering the load to determine the risk of failure. Since load data is large amount of data, it is necessary to make the variable load information equivalent to the time unit first in order to calculate the remaining life of the system quickly. In overseas literature, transformers are reported to be standardized for variable load equivalent conversion formulas, but they have not been reported for ultra-high voltage cables. Therefore, in this paper, whether the equivalent conversion formula of a transformer can be applied to XLPE cables was reviewed through accelerated degradation tests under equivalent and variable temperature conditions, and considerations were studied when evaluating the remaining operating life of XLPE cables based on the experimental results.

파형 GFRP 전단연결재의 폭 및 너비에 따른 중단열 벽체의 면내전단거동 (Effects of Corrugated GFRP Shear Connector Width and Pitch on In-plane Shear Behavior of Insulated Concrete Sandwich Wall Panels (CSWP))

  • 장석준;오태식;유영찬;김호룡;윤현도
    • 콘크리트학회논문집
    • /
    • 제26권4호
    • /
    • pp.421-428
    • /
    • 2014
  • 이 연구는 파형 GFRP 전단연결재가 보강된 중단열 벽체의 면내전단거동을 알아보기 위하여 실시되었다. 기존의 중단열 벽체의 단열성능 향상과 내/외측 벽체의 합성거동을 위하여 파형 GFRP 전단연결재를 보강하였다. 실험체는 2개의 단열재로 구분된 3개의 콘크리트 벽체로 구성되어 있으며, 중앙부 벽체에 수직방향의 전단력을 가하였다. 주요변수는 단열재의 종류 (압출법 보온판 및 비드법 보온판) 및 보강된 전단연결재의 너비(300 및 400 mm)과 폭(10 및 15 mm)를 변수로 설정하였으며, 실험체의 파괴양상 및 전단흐름강도-평균상대변위 관계 대한 분석을 실시하였다. 실험 결과 콘크리트와 단열재의 부착응력은 중단열 벽체의 초기거동에 상당한 영향이 있는 것으로 판단되며, 전단연결재가 보강되지 않은 경우 XPSS를 사용한 중단열 벽체의 강성 및 강성이 EPS 단열재의 경우보다 높게 나타났다. 전단연결재의 보강효과는 단열재에 따라 상이하게 나타났으며, 전단연결재의 보강상세에 단열재의 역학적 특성을 고려해야 할 것으로 판단된다.