• Title/Summary/Keyword: Insulation Strength

Search Result 638, Processing Time 0.027 seconds

Design of Aluminium Extruded Panel for Sound Insulation (알미늄 압출재의 차음 구조 설계)

  • Seo, Tae-Gun;Kim, Seock-Hyun;Kim, Jeong-Tae;Song, Dal-Ho
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.996-999
    • /
    • 2010
  • Aluminium extruded panel is the most important element for sound insulation in a express train. However, comparing with the flat plate with the same weight, the extruded panel shows remarkably low sound transmission loss above the 1st local resonance frequency, which is determined by the dimension of the core structure. Preceding study showed the possibility of the improvement of sound insulation performance by properly designing the core dimension. By the proper core design, local resonance frequency shifts to higher frequency region without any reduction of bending or torsional strength and without any weight increase. Based upon this result, this study investigates in detail the design modification of the core structure of the aluminium extruded panel used in a express train under development, in aspect of sound insulation. Design result is compared with those of other developed models.

  • PDF

A study of the Insulation Characteristic in $SF_6-N_2$ Mixture Gases ($SF_6-N_2$ 혼합기체의 절연특성에 관한 연구)

  • Ha, Sung-Chul;Song, Byoung-Doo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.613-616
    • /
    • 2001
  • This SF6 gas is widely used in industrial of insulation field. In this paper, N2 is mixed to improve pure SF6 gas characteristics. Electron transport coefficients in SF6-N2 mixture gases are simulated in range of E/N values from 70 to 400 [Td] at 300K and 1 Torr by using Boltzmann equation method. The results of this method, which are like electron drift velocity, ionization coefficient, attachment coefficient, effective ionization coefficient, and critical EIN, can be important data to present characteristic of gas for insulation. Specially critical E/N is a data to evaluate insulation strength of a gas and is presented in this paper for various mixture ratios of SF6-N2 mixture gases.?⨀␍?܀㘱〮㜳㬓M敤楣楮攠慮搠桥污瑨

  • PDF

A Study on the heating conditions affect on the insulation characteristics of polyamid papers (가열조건이 폴리아미드지의 절연특성에 미치는 영향)

  • Sun, J.H.;Kim, W.S.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2047-2049
    • /
    • 2000
  • In this study, we describe comparison of insulation characteristics of polyamid papers with heating conditions. The partial discharge behavior until breakdown and breakdown strength for thermal degradation films are observed in $SF_6$ gas chamber. The four layered NOMEX films of thickness of 50${\mu}m$ were used as solid insulation films and the sphere of which diameter is 40mm to sphere electrode system was used and each insulation films were inserted between sphere electrodes. The used gas pressure was 1.0bar and used temperature was each of 250$^{\circ}C$, 270$^{\circ}C$, 300$^{\circ}C$, 320$^{\circ}C$, 350$^{\circ}C$ and the voltage were applied until breakdown films.

  • PDF

A study of the Insulation Characteristic in $SF_{6}$-$N_2$ Mixture Gases ($SF_{6}$-$N_2$ 혼합기체의 절연특성에 관한 연구)

  • 하성철;송병두
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.613-616
    • /
    • 2001
  • This $SF_{6}$ gas is widely used in industrial of insulation field. In this paper, $N_2$ is mixed to improve pure $SF_{6}$ gas characteristics. Electron transport coefficients in $SF_{6}$-$N_2$ mixture gases are simulated in range of E/N values from 70 to 400 [Td] at 300K and 1 Torr by using Boltzmann equation method. The results of this method, which are like electron drift velocity, ionization coefficient, attachment coefficient, effective ionization coefficient, and critical E/N, can be important data to present characteristic of gas for insulation. Specially critical E/N is a data to evaluate insulation strength of a gas and is presented in this paper for various mixture ratios of $SF_{6}$-$N_2$ mixture gases.

  • PDF

High Temperature Properties in Finishing Mortars of Exterior Insulation Finishing System Using Fly Ash and Waste Glass Powder (플라이애시와 폐유리분말을 사용한 외단열용 마감모르타르의 고온 특성)

  • Song, Hun;Shin, Hyeon Uk
    • Resources Recycling
    • /
    • v.28 no.6
    • /
    • pp.64-72
    • /
    • 2019
  • Fly ash has different chemical composition depending on the type and quality of flaming coal. Fly ash is classified according to carbon content and particle size. Waste glass powder is manufactured by crushing glass. Exterior Insulation Finish System (EIFS) is generally applied by using poly-styrene foam which is economical and has excellent thermal insulation performance. However, poly-styrene foam has excellent insulation performance, but it is vulnerable to fire, which is becoming a serious problem. In this study, using a fly ash and waste glass powder to produce a finishing mortar at high temperatures. Also, High temperature strength and flame retardant properties were tested according to the cover thickness. From the test result, finishing mortar prepared using fly ash and waste glass powder is due to the improved heat resistance by alkali-activated bonding. However, since the strength decreases at high temperatures, it is necessary to select an appropriate mixing proportion.

Impulse Breakdown Behaviors of Dry Air as an Alternative Insulation Gas for SF6

  • Li, Feng;Yoo, Yang-Woo;Kim, Dong-Kyu;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.24-32
    • /
    • 2011
  • [ $SF_6$ ]gas, which has an excellent dielectric strength and interruption performance, is used in various applications such as gas insulated switchgear (GIS) in substations. However, since $SF_6$ has a high global warming potential (GWP), it is necessary to find an eco-friendly alternative insulation gas. In order to examine the possibility of using alternative insulation gases for $SF_6$ in power distribution system equipment, the dielectric strength and physical phenomena of dry air in a quasi-uniform electric field are investigated experimentally in this paper. As a result, the breakdown voltages for positive polarity are higher than those for negative polarity under impulse voltage applications. The negative 50[%] flashover voltage, $V_{50}$ of dry air under conditions above 0.4[MPa] gas pressure, is higher than 150[kV], that is the basic impulse insulation level of distribution equipment. The $V_{50}$ increases linearly with increasing the gas pressure, regardless of the waveform and polarity of the applied impulse voltages. The voltage-time curves are dependent on the rise time of the impulse voltage and gas pressure. Furthermore, streamer discharge was observed through light emission images by an ICCD camera under impulse voltage applications.

Insulation Aging Characteristic Assessment on the Power cables with the Comparative Analysis Between Destructive and Nondestructive Diagnosis (파괴 및 비파괴진단 비교분석을 통한 케이블 열화특성평가)

  • Yi, Dong-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.104-108
    • /
    • 2009
  • The insulation aging characteristics and structural analysis test were performed to analyze the correlations among the insulation deterioration, diagnostic results and the breakdown strength for the underground power cables. From the results of the degree of crosslinking test, hot-oil test etc., it could be confirmed that there were no manufacturing defects in the power cables under test. From the results of the water tree test and chemical structural analysis, it could be confirmed that the aging status of cable under test were very poor, especially for B-Phase and the degree of aging was increased in the orders of A, C and B-phase. From the above results, it could be concluded that the insulation aging characteristic analysis results were well consistent with the diagnostic and breakdown test results, and also confirmed that the diagnostic system under consideration was successful to discriminate the bad cables which is likely to cause cable system failure.

A Study on the Insulation Characteristics of Epoxy Composites Using Electric Field Simulation

  • Lee, Deok-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.2
    • /
    • pp.53-60
    • /
    • 2021
  • In this paper, we aimed to identify the insulation characteristics and reliability of Epoxy composites, which are widely used as insulation material for electrical & electronic components and electric appliance. To this end, it was necessary to predict variations of electric field due to the distribution of fillers that must be added by economic and mechanical factors. So, we verified the result using an electric field analysis Simulator. Furthermore, under the condtion of DC voltage application, an dielectirc breakdown test was performed according to ambient temperature changes and the distribution of fillers, and the changes were observed. Three types of specimens were manufactured by adding 0, 50 and 100[phr] filling to Epoxy resin. In all specimens, as temperature was increased, the strength of the dielectric strength was decreased. When comparing the simulation results with the actual dielectric breakdown test results, we was able to confirm the technical applicability required for Insulation design of electric appliance.

Thermal Characteristics of Cement Concrete Mixed with Wasted Vinyl Aggregates (폐비닐 골재가 혼합된 시멘트 콘크리트의 열 특성)

  • Yeom, Woo Seong;An, Gi Hong;Liu, Ju Ho;Jeong, Jin Hoon
    • International Journal of Highway Engineering
    • /
    • v.16 no.6
    • /
    • pp.79-86
    • /
    • 2014
  • PURPOSES : In this study, wasted vinyl aggregate, which possesses better thermal properties than natural aggregate, was used in cement concrete mixture to develop more economical concrete with thermal insulation and freeze prevention effects. METHODS : Slump and air content of the fresh concrete, which substituted its 0%, 5%, and 10% of coarse aggregate with wasted vinyl aggregate, were measured. Compressive strength, Poisson's ratio, elastic modulus, and splitting tensile strength of hardened concrete were measured by laboratory tests. Thermal properties of concrete such as coefficient of thermal expansion, thermal conductivity, and specific heat were also measured according to replacement ratio of wasted vinyl aggregate. Finally, the thermal insulation and freeze prevention effectiveness of the concrete mixed with wasted vinyl aggregate was confirmed through finite element analysis of road pavement crossing above concrete box culvert made from wasted vinyl aggregate. RESULTS : Even though the physical properties of wasted-vinyl-aggregate concrete such as compressive strength, Poisson°Øs ratio, elastic modulus, and splitting tensile strength were inferior to those of ordinary concrete, they met requirements for structural concrete. The thermal properties of concrete were improved by wasted vinyl aggregate because it decreased thermal conductivity and increased specific heat of the concrete. According to the result of finite element analysis, temperature variation in pavement subgrade was mitigated by box culvert made from wasted-vinyl-aggregate concrete. CONCLUSIONS : Through the laboratory test and finite element analysis of this study, it was concluded that the concrete structures made from wasted vinyl aggregate showed thermal insulation and freeze prevention effects.

The Effects of Kevlar Pulp on Polyurethane Foam for Cryogenic Temperature (극저온용 폴리우레탄 폼에 미치는 케블라 펄프의 영향)

  • Oh, Jong-Ho;Bae, Jin-Ho;Lee, Jae-Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.6
    • /
    • pp.514-520
    • /
    • 2018
  • Polyurethane foam has excellent mechanical strength and insulation performance, and has been adopted as an insulation material for $-163^{\circ}C$ liquefied natural gas carrier. In this study, Kevlar Polyurethane Foams(K-PUF) were synthesized by adding Kevlar pulp with excellent mechanical strength for the purpose of improving the performance of existing polyurethane foam. Since polyurethane foam has mechanical performance depending on the proportions of Kevlar pulp added, the mechanical strength of the K-PUF with ratios of fiber0.2wt.%, 0.4wt.%, 0.6wt.%, 0.8wt.% and 1.0wt.%) was evaluated. The compression tests were performed on the 4 different temperatures($20^{\circ}C$, $-50^{\circ}C$, $-110^{\circ}C$ and $-163^{\circ}C$) in consideration of the environmental characteristics as a cryogenic insulation used in LNG carrier. Besides, the effects of the fiber addition on polyurethane foam with closed cell structure were evaluated in a phenomenological approach through SEM analysis. All the results were compared to Neat-polyurethane foam. As a results, 0.8wt.% K-PUF showed the improved mechanical strength, and the addition of Kevlar pulp in a certain ratio improves the mechanical performance by enhancing the compression resistance.