• Title/Summary/Keyword: Insulation Oil

Search Result 258, Processing Time 0.021 seconds

Investigations on Partial Discharge, Dielectric and Thermal Characteristics of Nano SiO2 Modified Sunflower Oil for Power Transformer Applications

  • Nagendran, S.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1337-1345
    • /
    • 2018
  • The reliability of power transmission and distribution depends up on the consistency of insulation in the high voltage power transformer. In recent times, considering the drawbacks of conventional mineral oils such as poor biodegradability and poor fire safety level, several research works are being carried out on natural ester based nanofluids. Earlier research works show that sunflower oil has similar dielectric characteristics compared with mineral oil. BIOTEMP oil which is now commercially available in the market for transformers is based on sunflower oil. Addition of nanofillers in the base oil improves the dielectric characteristics of liquid insulation. Only few results are available in the literature about the insulation characteristics of nano modified natural esters. Hence understanding the influence of addition of nanofillers in the dielectric properties of sunflower oil and collecting the database is important. Considering these facts, present work contributes to investigate the important characteristics such as partial discharge, lightning impulse, breakdown strength, tandelta, volume resistivity, viscosity and thermal characteristics of $SiO_2$ nano modified sunflower oil with different wt% concentration of nano filler material varied from 0.01wt% to 0.1wt%. From the obtained results, nano modified sunflower oil shows better performance than virgin sunflower oil and hence it may be a suitable candidate for power transformer applications.

Electrical Characteristics Analysis According to Electrode Shape and Distance Between Electrodes (전극 형태와 전극 간 거리에 따른 전기적 특성 분석)

  • Tae-Hee Kim;Soon-Hyung Lee;Mi-Yong Hwang;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.4
    • /
    • pp.408-412
    • /
    • 2023
  • In this paper, in order to analyze high electrical insulation and cooling performance using mineral oil, the liquid insulating oil was changed in electrode shape and distance between electrodes to compare and analyze electrical characteristics according to equal electric field, quasi-equivalent electric field, and unequal electric field. As a result, the breakdown voltages were 36,875 V and 36,875 V in the form of sphere-sphere and plate-plate electrodes with equal electric fields. The breakdown voltage was 31,475 V in the sphere-plate electrode type, which is a quasi-equilibrium field, and the breakdown voltage was 28,592 V, 27,050 V, and 22,750 V in the needle-needle, sphere-needle, and needle-plate electrode types, which are unequal fields. Through this, it is possible to know the difference in breakdown voltage according to the type of electric field. The more equal the field, the higher the breakdown voltage, and the more unequal field, the lower the breakdown voltage. The difference in insulation breakdown voltage could be seen depending on the type of electric field, the insulation breakdown voltage was higher for the more equal electric field, and the insulation breakdown voltage was lower for the more unequal electric field. Also, it was confirmed that the closer the distance between the electrodes, the higher the insulation breakdown voltage, the higher the insulation breakdown current, and the insulation breakdown voltage and the insulation breakdown current were proportional.

Partial Discharge Process and Characteristics of Oil-Paper Insulation under Pulsating DC Voltage

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Jiang, Tianyan;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.436-444
    • /
    • 2016
  • Oil-paper insulation of valve-side windings in converter transformers withstand electrical stresses combining with AC, DC and strong harmonic components. This paper presents the physical mechanisms and experimental researches on partial discharge (PD) of oil-paper insulation at pulsating DC voltage. Theoretical analysis showed that the phase-resolved distributions of PDs generated from different insulated models varied as the increase of the applied voltages following a certain rule. Four artificial insulation defect models were designed to generate PD signals at pulsating DC voltages. Theoretical statements and experimental results show that the PD pulses first appear at the maximum value of the applied pulsating DC voltage, and the resolved PD phase distribution became wider as the applied voltage increased. The PD phase-resolved distributions generated from the different discharge models are also different in the phase-resolved distributions and development progress. It implies that the theoretical analysis is suitable for interpretation of PD at pulsating DC voltage.

The degradation of insulation oil in power transformers by the evolution of gases, Tan $\delta$, moisture and total acid number (가스량, Tan $\delta$, 수분량, 전산가에 의한 유침 전력 변압기의 열화현상에 관한 연구)

  • Choi, Jong-Kab;Han, Min-Koo;Kwon, Tae-Won;Yun, Yong-Bum
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.159-163
    • /
    • 1989
  • The various degradation phenomena, such as the evolution of gases, tan $\delta$, moisture content and total acid number in power transformer insulation oil, have been measured and analyzed. Mineral oil has been degraded at laboratory by the forced thermal stress of $60^{\circ}C$ and $90^{\circ}C$ respectively. Thermal aging oil has been degraded about 17, 34, 72 days. Also, we extracted insulation oil from working transformers. We measured gases dissolved in samples, tan $\delta$, moisture content, total acid number. Activation energy and resistivity is calculated from them. It is found that gases and tan $\delta$ increases as partial discharge and total acid number increases and that conductivity of the sample increases as activation energy increases.

  • PDF

Characteristics of Static Electrification on Insulation Oil Aging (변압기 절연유의 열화에 따른 대전특성)

  • Kweon, Dong-Jin;Kim, Han-Sang;Chong, Yong-Ki;Kim, Kyoung-Wha;Kim, Du-Seok;Kwak, Hee-Ro;Park, Tong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1615-1618
    • /
    • 1994
  • This paper studied the streaming electrification of the U.H.V. transformer with the spinning cylinder system, and compared and analyzed it with the conventional forced flowing system which uses a pump or gas for oil flowing. Also, accumulated surface voltage in its electrified material was measured with the electrostatic voltmeter, and the effect of insulation oil aging was measured. As results, in spinning cylinder system, characteristics of the streaming electrification to its rotational speed and oil temperature are same tendency as those of tile forced flowing system and it showed the spinning cylinder system is useful to study the streaming electrification. And, aging of insulation oil increases the electricity of streaming electrification at initial stage of aging.

  • PDF

Breakdown Properties for Insulation Design of the Environment-Friendly Pole Transformer using the Vegetable Insulating Oil (식물성절연유를 사용한 친환경 주상변압기 설계를 위한 절연파괴 특성)

  • Kwag, Dong-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.7-12
    • /
    • 2011
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. The newly invented vegetable insulating oil is highly biodegradable and have negligible impact on the environment, human health and the ecosystem. For development of the environmental-friendly pole transformer using vegetable insulating oil, the dielectric constructions of the pole transformer were discussed in this paper. Depending on the dielectric constructions, the AC breakdown characteristics of the Nomex insulating papers and the vegetable insulating oil were studied by simulated electrode systems. Based on the experimental results, the maximum design stress($E_{max}$) for insulation design of the environmental-friendly pole transformer were suggested.

Space Charge Behavior of Oil-paper Insulation Thermally Aged under Different Temperatures and Moistures

  • Zhou, Yuan-Xiang;Huang, Meng;Chen, Wei-Jiang;Jin, Fu-Bao
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1124-1130
    • /
    • 2015
  • Moisture and high temperature are the most important factors that lead to the ageing of oil-paper insulation, but the research about space charge characteristics of oil-paper insulation does not take the combined effect of ambient temperature, moisture and thermal ageing into account. The pulsed electroacoustic (PEA) method was used to investigate the influence of moisture and temperature on space charge characteristics of oil paper at different ageing stages. The results showed that moisture could speed up formation of space charge in oil paper when water concentration was low, but the formation was restrained if the water concentration was high. At the beginning of thermal ageing, heterogeneous charge accumulation had predominance, but it gradually changed to homogeneous charge injection with ageing. It was believed that moisture concentration could speed up ageing and enhance charge accumulation on one hand, and accelerate or slow down the establishment speed of space charge on the other hand, therefore, charge accumulation type changed with ageing. The more seriously the oil-paper insulation was thermally aged, the deeper the trap energy level was, hence more space charge was trapped, which could be speeded up by increasing the ageing temperature, but the effect of ambient temperature did not fit the Arrhenius law.

Analysis of Produced By-products Due to Oil/Paper Degradation on Power Transformers (전력용 변압기의 열화에 의해 생성된 부산물의 분석)

  • Kim, Jae-Hoon;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1561-1565
    • /
    • 2007
  • According to thermal degradation on power transformers, it is known that electrical, mechanical and chemical characteristics for power transformer's oil-paper are changed. In the chemical property, especially, when the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. Also the paper breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furanic degradation products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. Recently, the analysis of furanic compounds by high performance liquid chromatography(HPLC) using IEC 61198 method for estimating degradation of paper insulation in power transformers has been used more conveniently for assessment of oil-paper. It is know that the main products which is produced by aging are 2-furfuryl alcohol, 2-furaldehyde(furfural), 2-furoic acid, 2-acetylfuran, 5-methyl-2-furaldehyde, and 5-hydroxymethyl-2-furaldehyde. For investigating the accelerated aging process of oil-paper samples we manufactured accelerating aging equipment and we estimated variation of insulations at $140^{\circ}C$ temp. during 500 hours. Typical transformer proportions of copper, silicon steel and iron have been added to oil-paper insulation during the aging process. The oil-paper insulation samples have been measured at intervals of 100 hours. Finally we have analyzed that 2-furoic acid and 2-acetylfuran products of furanic compounds were detected by HPLC, and their concentrations were increased with accelerated aging time.

A Study on PCB Analysis of Insulating Oil in Waste Condenser (폐콘덴서의 절록유 중에 함유된 PCB 분석에 관한 연구)

  • 김귀자;박재주
    • Environmental Analysis Health and Toxicology
    • /
    • v.4 no.1_2
    • /
    • pp.11-17
    • /
    • 1989
  • A quantitative analytical method of highly concentrated PCB is established in the research. With the quantitative analytical method PCB of insulating oil was examined. The following conclusions are derived from this research. 1. The recovery ratio was 95.7% with the quantitative analytical method, which indicates it can be used for the analysis of PCB. 2. PCB concentration of insulation oil in waste condenser was found to be 21.2% thru 13.85% , which was highly concentrated. 3. PCB insulation oil in waste condenser was same as PCB-42.

  • PDF

Effect of Decomposition Product on the Insulation Characteristics of Mineral Oil as Insulation Medium of Distribution Transformer (주상변압기의 절연매질인 광유의 절연파괴특성에서 분해생성물의 영향)

  • Lim, Dong-Young;Park, Sung-Gyn;Park, Cheol-Ho;Kim, Ki-Chai;Lee, Kwang-Sik;Choi, Eun-Hyeok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.52-59
    • /
    • 2014
  • This paper deals with the effect of decomposition products which occur in breakdown of mineral oil, on the insulation characteristics of its oil. Breakdown tests in the oil were conducted by the proposed experimental methods under a quasi-uniform field and AC HV (60Hz). The breakdown voltage in the oil shows characteristics of dispersion from successive breakdowns and, it is found that there are three patterns of the decomposition products behavior at the process of breakdown progress in the oil. Finally, the breakdown voltage dispersion in the oil can be described in detail based on the behavior patterns of the decomposition products and its diffusion time.