• 제목/요약/키워드: Insulation Oil

Search Result 258, Processing Time 0.027 seconds

PCBs concentration and congener distribution in transformer insulation oil samples using GC/ECD and HRGC/HRMS analysis (GC/ECD와 HRGC/HRMS 분석을 이용한 변압기 절연유 중 PCBs 농도 및 이성체 분포)

  • Kim, Kyoung-Soo;Kim, Hyoung-Seop;Song, Byung-Joo;Jeong, Mi-Jeong;Kim, Jong-Guk;Park, Seok-Un;Shin, Sun-Kyoung
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.232-240
    • /
    • 2005
  • The total PCBs level in the transformer insulation oil samples using GC/ECD and HRGC/HRMS were ranged from 0.087 to $223.6{\mu}g/g$ and ranged from N.D. to $154.04{\mu}g/g$, respectively. The calculated TEQ values were ranged from 0.00067 to 6.8 ng WHO-TEQ/g. Among the samples, 6 samples showed higher than 2 ppm concentration (specific waste criterion of Korea). A variety in the concentration of total PCBs were observed between ECD and HRMS analysis. This is maybe due to quantification mehtod. The Aroclor 1248 wasn't present in the samples. The distribution pattern of Co-PCB congeners showed that the ratio of monoortho substituted congeners were higher than non-ortho substituted congeners. Among that, PCB-167 congener was predominant. In addition, the distribution of Co-PCBs congeners was different with that of flue gas and ambient air samples as well as commercial PCB formulations (Aroclor, Kanechlor).

A Study on the Heat Transfer Characteristic of Insulated Multi Core Tube (단열 다심관의 열전달 특성에 관한 연구)

  • Park, Sang-Kyun;Lee, Tae-Ho;Kim, Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.604-608
    • /
    • 2015
  • In this paper, we study the characteristics of heat transfer for an insulated multi-core tube using glass wool as an insulator for the multi-core tube. By performing experiments and modeling, we examine the variations in the temperature characteristics of hydraulic oil inside the multi-core tube with atmosphere temperature, inlet temperature, and the flow rate of hydraulic oil for the insulated multi-core tube that we developed. When the minimum inlet flow rate of hydraulic oil employed within the scope of the research is 0.29 l/min, the temperature difference obtained in the experiments and numerical analysis was a maximum of $3^{\circ}C$. For a constant atmospheric temperature, as the inlet temperature of the hydraulic oil increases, the outlet temperature of the hydraulic oil will also increase, regardless of its inlet flow rate. Further, when the inlet flow rate of the hydraulic oil is more than 1.01 l/min, the effect of the atmospheric temperature on the temperature drop of the hydraulic oil is low.

Study on the Damage Pattern Analysis of a 3 Phase 22.9/3.3kV Oil Immersed Transformer and Judgment of the Cause of Its Ignition (3상 22.9/3.3kV 유입변압기의 소손패턴 해석 및 발화원인 판정에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1274-1279
    • /
    • 2011
  • The purpose of this paper is to present the manufacturing defect and damage pattern of a 3 phase 22.9/3.3kV oil immersed transformer, as well as to present an objective basis for the prevention of a similar accident and to secure data for the settlement of PL related disputes. It was found that in order to prevent the occurrence of accidents to transformers, insulating oil analysis, thermal image measurement, and corona discharge diagnosis, etc., were performed by establishing relevant regulation. The result of analysis performed on the external appearance of a transformer to which an accident occurred, the internal insulation resistance and protection system, etc., showed that most of the analysis items were judged to be acceptable. However, it was found that the insulation characteristics between the primary winding and the enclosure, those between the ground and the secondary winding, and those between the primary and secondary windings were inappropriate due to an insulating oil leak caused by damage to the pressure relief valve. From the analysis of the acidity values measured over the past 5 years, it is thought that an increase in carbon dioxide (CO2) caused an increase in the temperature inside the transformer and the increase in the ethylene gas increased the possibility of ignition. Even though 17 years have passed since the transformer was installed, it was found that the system's design, manufacture, maintenance and management have been performed well and the insulating paper was in good condition, and that there was no trace of public access or vandalism. However, in the case of transformers to which accidents have occurred, a melted area between the upper and the intermediate bobbins of the W-phase secondary winding as well as between its intermediate and lower bobbins. It can be seen that a V-pattern was formed at the carbonized area of the transformer and that the depth of the carbonization is deeper at the upper side than the lower side. In addition, it was found that physical bending and deformation occurred inside the secondary winding due to non-uniform pressure while performing transformer winding work. Therefore, since it is obvious that the accident occurred due to a manufacturing defect (winding work defect), it is thought that the manufacturer of the transformer is responsible for the accident and that it is lawful for the manufacture to investigate and prove the concrete cause of the accident according to the Product Liability Law (PLL).

The Effect of Needle Electrode in the Static Charge Elimination Methodes for Streaming-Electrification Insulating Oil (유동대전된 절연유의 제전방식중 침전극 삽입의 영향 (IV))

  • Chung, K.H.;Lim, H.C.;Kim, Y.W.;Hwang, M.W.;Paek, Y.C.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1202-1204
    • /
    • 1995
  • In this paper, We investigated a charge elimination by using a needle electrode in order to prevent the electrification phenomena of insulating oil flowing by force at the internal transformer. In our experiment, We used Acryle and Teflon as the material of charge reducer and measured each of their streaming current and needle electrode current. As a result of experiment, We can explain that the current of needle electrode increase in proportion to insulation of charge reducer.

  • PDF

Synthesis of POSS Derived Organic-Inorganic Hybrid Esters for Insulating Oil Applications

  • Choi, Kyeong-Min;Harshavardhan, S.J.;Sridhar, Ch.;Vijaykumar, B.V.D.;Kumar, Deepak;Jang, Kiwan;Lee, Man-Sig;Shin, Dong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2769-2773
    • /
    • 2014
  • In this work, a new family of polyhedral oligomeric silsesquioxanes (POSS) based esters have been synthesized that consists eight ester functional groups. These are classified into Type-I and Type-II esters based on the starting materials, octakis(3-chloropropyl)silsesquioxane (Cl-POSS) and octakis(3-hydroxypropyldimethylsiloxy) octasilsesquioxane (OHPS) respectively. These new POSS type ester moieties can be used as insulating oils and oil additives in the transformers and also considered to be alternatives to mineral and vegetable oils that are presently used in the insulation system.

Development of a Hydraulic Power Package Enclosed with an Electric Motor (모터 일체형 유압 파워 패키지의 개발)

  • Park, Y.H.;Lee, C.D.;Lee, J.K.
    • Journal of Power System Engineering
    • /
    • v.4 no.3
    • /
    • pp.55-61
    • /
    • 2000
  • In this study, a new design of an one-body type of an unbalanced-fixed- displacement type vane pump combined with an induction type electric motor was suggested. By the application of the new design scheme, it was possible to reduce the number of parts of the pump system and to cut down the volume of power package than that of already-used products. The case in this study enabled efficient heat transfer and electricity insulation of hydraulic fluid. Thus oil moves through the inside of the package for cooling and returns to the reservoir. Because of this design, it was difficult to measure the shaft-input torque. Therefore the package overall efficiency in the paper was evaluated with a ratio of hydraulic power and electric power.

  • PDF

Study on Diagnosis for Transformers by Tan $\delta$ and Moisture of Insulation Oil According to Thermal Aging (절연유의 열열화에 따른 Tan $\delta$와 수분의 변화에 의한 변압기의 예방진단 연구)

  • HwangBo, Seung;Han, Min-Koo;Kwak, Hee-Ro;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.241-245
    • /
    • 1988
  • This paper reports the experiments regarding to diagnosis techniques for power transformers by measuring dissipation factor and moisture contents of mineral oils. Thermal aging environments of mineral oils were varied by the specially designed systems. Thermal aging of elevated temperature of $90^{\circ}C$ was performed for about 240 and 460 hours, respectively. Dissipation factor, permittivity, and water content were measured. Our test samples were not exposed to air. Dissipation factor increased while permittivity did not change. The level of dissipation factor determining the insulating quality of mineral oil was compared with the previous results of resistivity and several correction factor.

  • PDF

전략케이블에 쓰이는 절연재료의 변천과 발달과정

  • 구자윤
    • 전기의세계
    • /
    • v.34 no.8
    • /
    • pp.476-488
    • /
    • 1985
  • 전기공학분야의 여러다른 부분과 같이 전력케이블 분야에서도 수많은 연구와 아울러 특히 19세기후반에 전력케이블의 제작에 성공한 것은 20세기에 들어와서 케이블과 이에 관련된 모든 기술이 빠른 속도로 발달하게된 주원동력이 되었다고 보아도 과언은 아니다. 비록 19세기 후반에 고무(rubber)를 사용하여 케이블 절연 하였지만, 그이후 약 70여년이상을 Impergnated paper(오일복합수지(oil compound resin)나 오일(oil)을 종이에 스며들게한 후 그 종이를 절연재료로 이용함)를 전력케이블 절연재료로 많이 사용하여 왔다. 아울러 OF cable의 제조기술도 향상되어 현재 매우 높은 전압과 상당한 전력용량를 충족시키는 전력케이블로서 발달을 계속하고 있다. 1960년대에 들어서서 extruded polymer material 이 전력케이블의 절연재료로 쓰이게 되었는데 현저하게 주로 쓰이는 재료로 폴리에틸렌인대, 그대로 순수한 상태로 또는 어떤 처리를 하여 쓰기도 한다. 그러나 EPR(ethylene propylene rubber)도 역시 개발중에 있다. Extruded synthetic insulation을 사용한 케이블은 현재 모든 필요한 전류와 전압을 망라하여 널리 쓰이고 있으며 다른재료를 사용한 케이블 보다 설치하기에 쉽고 사용법이 비교적 간단하고, 또한 전력망(network)에서의 신뢰서이도 높은 것으로 나타나 매우 만족스런 재료로 인정받고 있다.

  • PDF

Effective Control of Indoor Air Pollutant using VAV/BPFS (VAV/BPFS를 이용한 실내공기 오염물질의 효율적 제어)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.327-334
    • /
    • 1998
  • The oil crisis of the 1970s and the rise in oil prices motivated people to implement energy conservation strategies. Buildings were fitted with additional Insulation and reduced ventilation rates. The reduction of mechanical and natural ventilation rate led to Increases In Indoor pollutant concentrations which result- ed In Increased health risks from Indoor exposure to pollutants. The variable-air-volume /bypass fitration system/VAV/BPFS) is a variation of the conventional VAV systems, The VAV/BPFS is an electronically controlled system that provides costegectlve thermal comfort and acceptable indoor air quality Under controlled conditions In a chamber, a series experiments were performed to compare the ability of a VAV/BPFS to remove Indoor aerosol concentration and to reduce energy consumption no that ability of conventional VAV system. Results show that the VAV/BPFS Increases the effective ventilation rate and removes indoor air pollutant, and maintains acceptable indoor air Quality without sacrificing energy consumption.

  • PDF

A moisture absorption characteristics of insulation papers on the vegetable oil impregnated paper and the mineral oil impregnated paper (회복전압측정 방법을 통한 식물유와 광유에 따른 절연지의 수분 흡습 특성)

  • Jeong, Jin-Hye;Han, Sang-Ok;Lee, Sei-Hyun;Park, Kang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2034-2035
    • /
    • 2008
  • 본 논문은 RVM(Return Voltage measurement)을 이용하여 식물유와 광유에 따른 절연지의 수분 흡습성에 관한 특성을 비교하였다. 시험 절연재료로써 절연유는 각각 식물유(Bio Trans 1000,Cargill사)와 광유(제1종 2호, 동남석유(주))를 사용하였고, 절연지는 셀룰로오스계 크래프트 절연지를 사용하였다. 각 조건에서 IEEE/ANSI Standard C59.91-1981의 기대수명 곡선에서 $55^{\circ}C$ 절연을 기준으로하여 가속 열열화 시험을 수행한 후, $15^{\circ}C$씩 온도를 변화시켜 RVM 측정을 하였다.

  • PDF