Predicting residual moment capacity of thermally insulated RC beams exposed to fire using artificial neural networks

  • Erdem, Hakan
    • Computers and Concrete
    • /
    • 제19권6호
    • /
    • pp.711-716
    • /
    • 2017
  • This paper presents a method using artificial neural networks (ANNs) to predict the residual moment capacity of thermally insulated reinforced concrete (RC) beams exposed to fire. The use of heat resistant insulation material protects concrete beams against the harmful effects of fire. If it is desired to calculate the residual moment capacity of the beams in this state, the determination of the moment capacity of thermally insulated beams exposed to fire involves several consecutive calculations, which is significantly easier when ANNs are used. Beam width, beam effective depth, fire duration, concrete compressive and steel tensile strength, steel area, thermal conductivity of insulation material can influence behavior of RC beams exposed to high temperatures. In this study, a finite difference method was used to calculate the temperature distribution in a cross section of the beam, and temperature distribution, reduction mechanical properties of concrete and reinforcing steel and moment capacity were calculated using existing relations in literature. Data was generated for 336 beams with different beam width ($b_w$), beam account height (h), fire duration (t), mechanical properties of concrete ($f_{cd}$) and reinforcing steel ($f_{yd}$), steel area ($A_s$), insulation material thermal conductivity (kinsulation). Five input parameters ($b_w$, h, $f_{cd}$, $f_{yd}$, $A_s$ and $k_{insulation}$) were used in the ANN to estimate the moment capacity ($M_r$). The trained model allowed the investigation of the effects on the moment capacity of the insulation material and the results indicated that the use of insulation materials with the smallest value of the thermal conductivities used in calculations is effective in protecting the RC beam against fire.

표면 절연층이 나노결정립 합금 리본의 자기적 특성에 미치는 영향 (The Effects of Surface Insulation Layer on the Magnetic Properties of Nanocrystalline Alloy Ribbons)

  • 오영우
    • 한국자기학회지
    • /
    • 제17권6호
    • /
    • pp.226-231
    • /
    • 2007
  • 나노결정질 비정질 리본 표면에 졸-겔법에 의해 제조된 $TiO_2$$SiO_2$ 졸을 딥 코팅법을 이용하여 절연막을 형성시킴으로써 전기 비저항의 증가를 통한 고주파 손실을 제어하고자 하였다. 졸-겔법에 의한 슬러리 제조에서, 금속 알콕사이드의 혼합조건 및 절연층 형성용 슬러리의 제조조건을 확립하였고, 비정질 합금 리본 표면에 균일하고 우수한 점착력을 가지는 절연층을 형성시킬 수 있었다. 그리고 표면 절연층이 형성된 나노 결정질 합금 재료를 이용하여 제조한 자심재료는 전기 비저항의 증가로 인해 코어 손실을 약 40% 이상 감소시킬 수 있었다. 또한 표면 절연층을 형성시킨 자심재료를 이용하여 제조한 비접촉식 커플러는 코어 손실의 감소로 인해 삽입손실의 감소 효과가 나타났으며, 삽입손실의 감소효과는 주파수 증가에 따라 증가하였다.

새만금 간척지 첨단온실 에너지 설계를 위한 풍환경 및 온실 피복재의 영향 분석 (Analysis on Insulation of Wind Environment and Greenhouse Cover Materials Insulation for Advanced Greenhouse Energy Design in Saemangeum Reclaimed Land)

  • 서효재;서일환;노득하;이학성
    • 생물환경조절학회지
    • /
    • 제32권1호
    • /
    • pp.57-63
    • /
    • 2023
  • 본 연구에서는 새만금과 같은 간척지를 활용하여 대규모 첨단온실단지를 조성하는 경우 간척지의 환경적 특수성 중 높은 풍속에 따른 유리 단열재의 에너지 효율을 평가하였다. 현장에서 주로 사용되는 온실 단열재 중 4가지에 대한 평가 결과, 최대 37.4%의 에너지 차이를 보여, 온실 피복재의 선정이 중요함을 제시하였다. 이를 바탕으로 일반적인 내륙에서의 온실을 설계하는 것과 달리, 간척지에서는 내재해성 온실규격을 따라 시설을 설계하여야 하며, 에너지 소비량은 높아진 풍속과 재질을 고려하여 산정되어야 한다. 본 연구의 결과는 에너지 효율성을 온실 피복재의 종류와 풍속에 따라서 제시하고 있으며, 이는 대규모 첨단온실 조성 시 에너지 소비량을 예측하고, 이를 바탕으로 신재생에너지원을 포함하는 에너지 설계에 활용될 수 있다

프레스 보드의 제작과 특성 평가(I) (Characteristics and Fabrication of Pressboard( I ))

  • 김귀열;엄승욱;강동필;윤문수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1993년도 추계학술대회 논문집
    • /
    • pp.67-70
    • /
    • 1993
  • A pressboard providing both good insulation and mechanical properties is required as for insulating material in oi1-immersed transformers insulation. This study has examined fabricating methods and specimen characteristics of pressboard.

  • PDF

고압회전기 권선용 에폭시 VPI 절연물의 개발과 평가 (Development and Evaluation of Epoxy VPI Insulation for High Voltage Rotating Stator Windings)

  • 이창용;최영찬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 학술대회 논문집 일렉트렛트 및 응용기술연구회
    • /
    • pp.38-42
    • /
    • 2003
  • The use of VPI impregnated mica tape as high voltage insulation for large rotating electric machines requires a careful balance of processes and materials to obtain the desired electrical, mechanical and thermal characteristics. The stator insulation systems such as epoxy bonded high voltage mica tape have been produced for many years. One such system employing an epoxy and anhydride impregnating resin developed by Hyundai Heavy Industries, Co. (hereafter, HHI), to satisfy customer requests for an epoxy bonded insulation system. HHI applies the following electrical and thermal evaluations such as dielectric breakdown, voltage endurance, dissipation factor vs. temperature, isothermal weight loss, and so on. A detailed laboratory evaluation can describe specific physical limitations for an insulation system and permit development of long-term operation guidelines that permit full utilization of the proposed system. HHI has found these evaluations very helpful in qualifying insulation system for the repair of both large motors and generators.

  • PDF

에폭시 몰드형 BCT의 절연열화 특성 (Characteristics of Insulation Degradation in Epoxy Mold Type BCT)

  • 송재주;이정철;임성훈;고석철;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.902-908
    • /
    • 2005
  • Various stresses (such as electrical stress, mechanical stress, environmental and electrochemical stress, and defects of structure) result in insulation degradation of epoxy mold type insulators. Since the insulation degradation of BCT(Bushing Current Transformer) and bushing proceeds during fabrication process or operation time due to these causes, various methods to reduce the degradation in their insulation ability have been suggested. In this paper, we investigated surface temperature increment of these insulators due to PD(partial discharge). After the voltage applied into the insulator to generate the artificial PD, the surface temperature of the insulator was measured with non-contact thermometer using infrared rays. It was confirmed through the analysis based on PD experiments that the procession in the insulation degradation of the insulator could be estimated through the measurement of the surface temperature in the insulator.

가속열화 방법에 의한 주상변압기 절연물의 열 열화 특성 평가 (The Evaluation of Thermal Aging Characteristics in Insulating Materials of the Pole Transformers)

  • 이병성;송일근;이재봉;한상옥
    • 한국전기전자재료학회논문지
    • /
    • 제16권12호
    • /
    • pp.1136-1141
    • /
    • 2003
  • The primary insulation materials used in an oil filled transformer are kraft paper, wood, porcelain and oil. Modern transformers use chemically treated paper to improve its tensile strength and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged by thermal stress. Over the life time of the insulation paper and oil, it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper used in the layer insulation. We made two aging cells in which insulation papers and mineral oil are conducted to test thermal properties. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

건조공기/에폭시 복합절연물의 AC 파괴전압 분석 (Analysis of AC Breakdown Voltage of Composite Insulation for Dry-Air/Epoxy)

  • 허준;이승수;임기조;정해은;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.289-290
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

철도차량 추진제어장치의 스트레스 분석 및 열화 메커니즘 (Stress Analysis and Degradation Mechanism of the Drive Control system for a Railway carriage)

  • 김기준;왕종배;최영찬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.21-24
    • /
    • 2000
  • Traction motors driven by several type inverters have been subjected to increasing demands for higher operating temperature, more demands for duty cycles, higher starting current, frequent voltage transients and finally severe environmental exposure. For applications to inverter duty, traction motors needs a special insulation system, which has characteristics of increased bond strength, lower operating temperature and higher turn-to-tum insulation. Also it needs major contributors to insulation life and reliability of motors, which more considered by temperature, voltage, frequency, rise time, pulse configuration, wire thickness and insulation materials. In this paper, to evaluate of reliability and expected life, it is analyzed the several stresses and their degradation mechanism on insulation system of AC traction motor.

  • PDF

공동주택용 외단열 동시타설 공법 적용을 위한 리스크 요인 평가 (Assessment of Risk Factors for Application of Exterior Insulation Board in Cast-in-place Concrete Form System for Apartment)

  • ;김태훈;임현수;조훈희;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.204-205
    • /
    • 2015
  • Exterior insulation board in cast-in-place concrete form system could reduce construction period and improve quality in apartment construction. However, the method is progressed with insulation and concrete frame works at the same time, then risk is increased in duration control and quality management. Therefore, this paper analyzed risk factors through FMEA method. We found that the key risk factors delaying schedule was insulation material that soaked in the rain and quality defects on the insulation material joint. Based on this research, the risk management approach should be developed for improvement of method activation.

  • PDF