• 제목/요약/키워드: Insulation Material

검색결과 1,332건 처리시간 0.033초

에폭시 몰드형 PT의 절연특성 개선 (Improvement on Property of Insulation in PT of Epoxy Mold Type)

  • 송재주;김성홍;최명호;이재;임성훈;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 기술교육위원회 창립총회 및 학술대회 의료기기전시회
    • /
    • pp.67-71
    • /
    • 2001
  • PT of epoxy mold type have tendency to occur dielectric breakdown in high voltage system. These are using for measurement of voltage or protection of system and application voltage is 25.8kV. Therefore, for improving a lots of problems like as partial discharge, we had analyze on the destroyed Epoxy molded type PT and processing of production. As a results, we concluded that the reason of dielectric breakdown was defect of processing and degradation of insulation by electrical stress. In this work, We presented a method of solution in processing of production. which is reduction of the PO which was occurred at the insulation material. so we must many try to remove faults, these problems are mainly to winding methods of 1st coil. the other side, Reformation of 1st coil improved property of PD and we could prove it with experiments.

  • PDF

고속철도구간 방음벽 제진재 시험제작 및 성능평가에 관한 연구 (A Study on Sample manufacturing and Performance Evaluation for Vibration Insulation Material of Noise Barrier for High-Speed Railway)

  • 김순철;강정옥;한광섭;전병찬;한종문
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.522-529
    • /
    • 2005
  • The commercial service of KTX from April 1st 2004 has realized that whole country has shrunk into half-day life zone and it opened the times of speed. However, some technical problems unexpected before service have been raised and, among them, the noise generation at train passing was claimed by the residents living nearby the track and it is often publicized by the broadcastings and newspapers. In case where the residential area is close to the track, the installation of noise barrier at trackside is the general measures for noise reduction on bridge section and earthwork section. In case of KTX project, such measures were actually taken without any exception; however, the noise level is still high. In this study, analysis for the reason of higher noise level in spite of which the noise barriers are being installed was carried out, the sample of insulation material effective for noise barrier was manufactured and the performance of the insulation material was evaluated to verify its effectiveness

  • PDF

고온초전도 직류 케이블용 절연재료인 PPLP의 직류 및 임펄스 절연 특성 (DC and Impulse Insulation Characteristics of PPLP for HTS DC Cable)

  • 김우진;방만식;김해종;조전욱;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제26권7호
    • /
    • pp.545-549
    • /
    • 2013
  • To realize the high-Tc superconducting (HTS) DC cable system, it is important to study not only high current capacity and low loss of conductor but also optimum electrical insulation at cryogenic temperature. A model HTS DC cable system consists of a HTS conductor, semi-conductor, cooling system and insulating materials. Polypropylene laminated paper (PPLP) has been widely adopted as insulating material for HTS machines. However, the fundamental insulation characteristics of PPLP for the development of HTS DC cable have not been revealed satisfactorily until now. In this paper, we will discuss mainly on the breakdown characteristics of 3 sheets PPLP in liquid nitrogen ($LN_2$). The characteristics of the diameter, location of butt-gap, distance between butt-gap length, pressure effect, polarity effect under DC and impulse voltage were studied. Also, the DC polarity reversal breakdown voltage of mini-model cable was measured in $LN_2$ under 0.4 MPa.

다겹보온자재의 보온성 비교 및 커튼개폐장치 개발 (Comparison of Heat Insulation Characteristics of Multi-layer Thermal Screen and Development of Curtain System)

  • 이시영;김학주;전희;염성현;이현주
    • 생물환경조절학회지
    • /
    • 제16권2호
    • /
    • pp.89-95
    • /
    • 2007
  • 겨울철 난방연료가 많이 소모되는 대규모 연동형 온실의 보온성을 향상시키기 위해 터널용 보온자재로 많이 사용되는 다겹보온커튼을 이용하여 기존의 부직포, 알루미늄스크린 등과 보온성을 상대적으로 비교하였다. 또한 다겹보온자재는 보온성이 높으나 두께가 두꺼워 전동모터를 이용한 자동개폐장치를 구성하기 어려운 단점이 있으므로 연동형 온실에 적용할 수 있는 고장이 적고 작동이 원활한 커튼 개폐장치를 개발하여 작물재배 및 난방연료 절감효과를 검토하였다. 다겹보온자재와 부직포, 알루미늄스크린 등의 보온커튼용 자재의 열 관류량을 측정하여 상대적인 보온효과를 비교한 결과 부직포에 비해 알루미늄스크린의 열관류량이 적었고, 알루미늄 및 화학솜의 3겹보온자재와 다겹보온자재는 알루미늄스크린에 비해 열관류량이 각각 23.3%, 43.0% 적게 나타나 다겹보온자재의 보온성이 우수한 것으로 판단되었다. 다겹보온자재는 여러 겹으로 누빈 조합형 보온자재이므로 두께가 두껍고 화학솜, 폴리폼 등 연신되기 쉬운 자재를 이용하므로 장기간 사용시 커튼 개폐장치의 예인선이나 보온자재가 처지게 될 우려가 있으므로 예인식과 권취식 개폐방법을 동시에 적용하여 보온커튼 개페장치를 구성하였다. 시험용 온실 에 다겹보온커튼과 부직포커튼을 설치하고 풋고추를 재배한 결과 다겹보온커튼 설치 온실에서 풋고추의 생육이 유리하였고 초기수량도 27% 정도 증수되었으며, 경유온풍기의 난방연료 소모량은 46%정도 절감되었다.

염수 및 분진에 의한 고분자 절연물의 표면누설전류 특성과 사고 위험성 (The Accident Hazards and Properties of the Surface Leakage Current on the Polymer Insulation caused by Salt-water and Dust)

  • 김영석;송길목;정진수;정종욱;김선구
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.129-135
    • /
    • 2007
  • 환경오염이 심한 분진 발생지역에서는 전기 사고가 자주 발생하기 때문에 전기설비에 대한 유지관리와 예방에 대한 연구가 필요하다. 특히 외부에 전기절연물이 장기간 노출되면, 쉽게 분진이 축적되고 수분, 습기 등에 의한 누설전류의 발생으로 전기사고에 이르게 된다. 따라서 본 연구에서는 분진, 염수 등에 의한 전기설비 절연재료 표면변화와 표면 누설전류를 측정하였다. 측정결과로부터 베이클라이트의 표면이 다른 재료보다 염수에 대한 영향이 심하였다. 또한 베이클라이트 표면 누설전류는 반복되는 염수 오염에 의해 증가하고 재료표면은 미소아크가 발생하고 탄화되었다. 따라서 절연물에서의 누설전류를 억제하기 위해서는 재료의 형태 및 표면 코팅 등이 변화가 필요하다.

재생페트를 이용한 고단열 패키징 개발과 기존의 스티로폼 및 종이 박스와의 단열성능 비교 (Development of High-insulation Packaging using Recycled PET and Comparison of Insulation Performance with Existing Styrofoam and Paper Boxes)

  • 류재룡;육세원;갈승훈;신양재
    • 한국포장학회지
    • /
    • 제25권3호
    • /
    • pp.111-116
    • /
    • 2019
  • Thermal insulation performance of new insulation packaging made of recycled PET nonwoven (thickness : 10 mm) was verified by conducting comparative experiment with an EPS box (thickness : 25 mm) and a double wall corrugated box (thickness : 7 mm). Three ice packs (300 g) were positioned 200 mm above the bottom inside each box, all of which are placed side by side and temperature change of 2 points (5mm under middle icepack and 130 mm under middle icepack) was recorded by data logger (GL-840, Graphtec) for 16 hours under the environment of 29℃. The new packaging box showed 75% higher insulation performance than the EPS box and 180% higher than the corrugated box. In order to figure out the reason for insulation performance difference among boxes, thermal conductivities of each box material were measured using heat flow meter (HFM436 lamda, Netzsch). U-value (thermal conductivity divided by thickness) of EPS was lower than recycled pet nonwoven by 57%, which seemed to be opposite to the result of insulation test of boxes. This was explained by high water vapor transmission rate of EPS (6 times higher than PET insulation) and air pocket effect of PET insulation.

가속열화에 따른 페놀수지 절연재료의 트래킹 특성에 관한 연구 (A Study on the Tracking Characteristics of Phenolic Resin Insulation Material Due to Accelerated Degradation)

  • 김시국;최수길;이춘하
    • 한국화재소방학회논문지
    • /
    • 제31권1호
    • /
    • pp.42-49
    • /
    • 2017
  • 본 논문은 가속열화에 따른 페놀수지 절연재료의 트래킹 특성에 관한 연구이다. 페놀수지 절연재료의 절연열화를 위해 가속수명 시험방법 중 아레니우스 방정식을 이용한 가속열화 실험을 진행하여 등가연수 0년, 10년, 20년, 30년, 40년 된 실험시료를 제작하였다. 그 후 가속열화된 실험시료를 대상으로 KS C IEC 60112 기준에 의한 트래킹 실험을 진행하였다. 가속열화에 따른 페놀수지의 트래킹 특성 측정결과 염화암모늄 0.1% 적하 시 등가수명 0년을 기준으로 위험성이 등가수명 10년 1.38배, 20년 1.45배, 30년 1.62배, 40년 1.94배 증가하는 것으로 나타났다. 염화암모늄 0.01% 적하 시 등가수명 년을 기준으로 위험성이 등가수명 10년 1.39배, 20년 1.52배, 30년 1.99배, 40년 5.30배 증가하는 것으로 나타났다. 실험 결과 노후화에 따른 절연열화가 오래될수록 트래킹 위험성이 커지는 것으로 나타났으며, 특히 등가수명 40년의 경우 그 위험성이 크게 증가하는 것으로 관측되었다. 따라서 노후화에 따른 절연열화 등의 위험성을 고려하여 제도적으로 권장 교체주기를 마련해 주는 것이 전기화재 발생 가능성 및 위험성을 최소화할 수 있을 것으로 생각된다.

이부자리의 보온력에 관한 연구( I ) -충전물의 보온성 - (Studies on the Thermal Insulation Effect of Bedding ( I ) - Warmth Retaining Property of Filling Material -)

  • 이송자;성수광
    • 한국의류학회지
    • /
    • 제16권3호
    • /
    • pp.251-256
    • /
    • 1992
  • As a basic expriment to find out the thermal insulation effect of bedding KES-F7 was used to measure. The warmth retaining ratio of the six kinds of filling materials as cotton, wool , silk, down, cotton/polyester was measured, and the infleunce on the warmth retaining ratio of the warmth retaining ratio and humidity by the material was investigated. The results obtained are as follows: 1. The warmth retaining ratio of each filling material was shown to range from $70\%$ to $77\%$ . The warmth retaining ratio of each material preyed to be high in order down> polyester> cotton/polyester>cotton>silk>wool fiber. 2. The warmth retaining ratio of each filling material decreased with the inclose of the humidity The effective reduction rate by filling fiber's was high in order wool>cotton>cotton/polyester>silk>down>polyester material. 3. The warmth retaining ratio of each filling material was shown to be in counter-correlation with the humidity, and the correlation coefficient (r=0.94-0.98) proved to be highly signi-ficant.

  • PDF

신축성에 따른 여고생 교복의 착용감에 관한 연구(제1보) -역학적 특성과 보온성에 관하여- (A Study on Wearing Sensations of Girls'High School Uniforms Based on Elasticity(1) -Focusing on Mechanical Properties and Insulation-)

  • 민경혜;류덕환
    • 한국의류학회지
    • /
    • 제27권5호
    • /
    • pp.545-553
    • /
    • 2003
  • A good school uniform leads students to good behavior and have them enjoy desirable school life. Therefore a better fabric for girls' high school uniform suggested through two series of studies; first, examined the various aspects of current uniforms. Second, made a new fabric for uniform considering elasticity for activity and comfortableness, and compared its characteristics with those of the current uniforms. The results are as follows; 1 Most of students wanted uniforms considering elasticity for activity and wearing. 2. The measurement of the elasticities of the uniform materials showed that the material which was made using the elastic material was more elastic than the currently used material by 42.12% in summer material and 20.05% in winter one. 3. The analysis using the combination of the values of mechanical properties showed that the elastic material was better in the wearing, tactile senses, and drape properties than the current material, even though it was a little worse in shape-stability. 4. To compare the thermal insulation, clo values were measured. For winter uniform, the elastic material was better than the current one in keeping warm. However, This study did not find any big difference between summer uniform materials.