• 제목/요약/키워드: Insulation Degradation

검색결과 230건 처리시간 0.023초

방사선이 LDPE박막의 결정구조에 미치는 영향 (The Effects on the Crystal Structure of LDPE thin film exposed Radiation)

  • 강전홍;김한준;유광민;박강식;김종석;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.181-184
    • /
    • 2000
  • LDPE pelet is distilled to make 0.5 Wt% solutions and fabricated as LDPE thin film by dropping the solution onto glass substrate, and then annealed the film to be crystalline. The structure is observed as crystalline regions and non-crystalline regions. The crystalline region is exposed at radiation and as the result, there appeared degradation at the total region of the crystal structure. It is considered therefore that radiation exposure at the crystal structure is badly effected on insulation property and lifetime of materials.

  • PDF

ATH를 첨가한 실리콘고무의 반복열화에 따른 전기적 특성변화(I) (The Change of Electrical Properties on Silicone Rubber Contained ATH under Cyclic Aging(I))

  • 오태승;이청;김기엽;박수길;류부형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.258-261
    • /
    • 2001
  • In this paper, aging characteristics of silicone rubber used for outdoor insulation have been investigated with regards to salt fog condition and heat aging effect. We look over the change of properties of silicone rubber in salt fog chamber with average leakage current monitoring for observing the transformation of surface degradation properties of silicone rubber with different ATH(alumina trihydrate, Al$_2$O$_3$$.$3H$_2$O) filler contents. Surface resistivity, SEM(Scanning Electro Microscope) were measured.

  • PDF

신경회로망을 이용한 절연 결함의 판별 (Discrimination of insulation defects using a neural network)

  • 최재관;김재환;김성홍;윤헌주;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.381-384
    • /
    • 1997
  • This paper describes the method of diagnosing the degradation by void defects of insulator inside in operation. Needle-shape void specimens, made from LDPE, were used to generate an electrical tree under ac voltage. The method uses a neural network system with input signal of AE patterns. AE pattern consists of the pulse count and average amplitude according to the phase angle. After the learning process was over, unknown emission patterns were put into the network. It was shown that the network discriminates the void deflects well. The effectiveness of the neural network system for partial discharge recognition was shown.

  • PDF

트래킹 휠 시험에 의해 열화된 폴리머애자의 섬락특성 평가 (The Evaluation of Flashover Characteristics of Polymer Insulators with Tracking Wheel Test)

  • 이병성;한재홍;윤태상;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.82-85
    • /
    • 2000
  • Polymeric composite insulators are used for outdoor insulation. However, our knowledge about their long-term performance in an outdoor environment is still very limited. The electrical stress caused the surface of these insulators to become degradation. In order to evaluate the tracking resistance of polymer insulators, we performed the tracking wheel test which is recommended by CEA LWIWG-01. And the flashover voltage tests were conducted for understanding electrical characteristics after tacking wheel test. Also, these insulators are studied by characterization methods such as contact angle measurement, SEM, etc.

  • PDF

플라즈마 표면개질에 따른 FRP의 자외선 열화 특성에 관한 연구 (A Study on the UV Degradation characteristics of FRP by Plasma Surface Modification)

  • 임경범;이상희;유도현;황명환;임응춘;조기선;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1544-1546
    • /
    • 2003
  • In this study, composite materials were put to dry interfacial treatment by use of plasma technology. It has been presented that the optimum parameters for the best wettability of the samples at the time of generation of plasma were oxygen atmosphere, 0.1 torr of system Pressure, 100 W of discharge power, and 3 minutes of discharge time. The decrease in surface potential of charged samples by corona discharge indicates that the amount of accumulated electrical charges reduces and the charges that have been injected lessen rapidly when the duration of UV irradiation increases. The surface resistivity and the tensile strength of plasma treated samples, a longer UV irradiation time resulted in decreased insulation.

  • PDF

HTS pancake 코일을 모의한 전극계에서의 전기절연 특성 (Electrical insulation characteristics with simulated electrode system of HTS)

  • 정종만;백승명;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.58-63
    • /
    • 2002
  • For the experiment the four types of spacer were distinguished by arrangement. The flashover characteristic on each types of spacer was investigated and the flashover phenomena were observed to understand breakdown mechanism in liquid nitrogen($LN_{2}$). The spacer should be placed interior coil as an insulator, a cooling channel and s supporter of structures. The simulated electrode used in the experiment was made from five turns of HTS tape. Experimental results revealed that multi-layer and barrier effects did work well in Air but did not in $LN_{2}$. These result suggested that the flashover in LN2 caused by the bubbles due to partial discharge at micro gap, g. The flashover characteristics decreased to 70% when g is 0.2 mm. The degradation was improved by even treatment on surface of coil electrode.

  • PDF

디젤전기기관차 전기장치 노후도 평가 (Deterioration Analysis of Electric Systems in Diesel Electric Locomotives)

  • 김정국;백승구;이창영;권성태;권석진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1213-1219
    • /
    • 2008
  • The deterioration analysis of electric systems in diesel electric locomotives, which were used for over 30 years, was performed to understand current wear and safety information. The electric systems include electric generation, traction motors, control units, high-voltage cables, and wires. In this investigation, various types of performance testing, such as insulation resistance measurement and degradation tests, were conducted to assess the degree of current deterioration. Moreover, an infrared camera was employed to verify abnormal heating in cables and wires. In this paper, the new techniques for evaluation of deterioration in electric systems have been introduced.

  • PDF

XLPE 절연체의 트리 채널내 보이드방전에 의한 AE신호로 절연열화 검출 기법 연구 (Fundamental Study of Degradation Diagnosis using AE Signals with Void Discharge in XLPE Insulation)

  • 이상우
    • 조명전기설비학회논문지
    • /
    • 제20권2호
    • /
    • pp.75-80
    • /
    • 2006
  • 본 논문은 전력 케이블의 절연체인 XLPE 시료에 상용주파수 교류전압을 인가하였을 때, 절연열화에 의한 보이드방전 펄스신호와 AE신호 및 트리진전 특성을 검출하고 관찰하였다. 또한 XLPE 절연체의 트리 채널내 인가전압에 따라 보이드방전 펄스신호와 AE신호를 각각 관측하였다. 실험 결과 전력 케이블의 절연체인 XLPE 시료의 보이드 존재 유 무에 따른 트리진전 형상은 보이드 존재시에는 수지형으로 성장하였으나, 무보이드시에는 수초형으로 성장하였다. XLPE 절연체내의 트리진전 특성은 보이드 존재시에는 열화시간이 경과함에 따라 급격히 증가하였으나, 무보이드시에는 열화 시간이 경과함에 따라 트리의 성장 형상은 감소되는 것으로 나타났다. 전력 케이블 절연체인 XLPE의 트리 채널내 보이드방전에 의한 AE신호의 주파수 스펙트럼으로 분석한 결과, AE신호의 크기에 따라 변화되었으며 그 주파수 영역은 대략 1.0[MHz] 이하의 분포인 것으로 관측되었다.

유도초음파기술을 이용한 배관 감육 평가 (Assessment of Pipe Wall Loss Using Guided Wave Testing)

  • 주경문;진석홍;문용식
    • 비파괴검사학회지
    • /
    • 제30권4호
    • /
    • pp.295-301
    • /
    • 2010
  • 원자력발전소 탄소강 배관의 유체가속부식은 주요 경년열화 현상이며 발전소의 성능 및 안전성을 저해할 수 있다. 유체가속부식 검사는 보온재 제거 및 설치로 상당한 비용이 수반되므로 최근에 보온재 제거가 필요 없고 원거리 검사가 가능한 유도초음파에 대한 관심이 점점 증가되고 있다. 유체가속부식 검출에 유도초음파 적용이 가능하다면 검사 비용 절감이 예상된다. 본 연구의 목적은 유체가속부식 손상 유무를 확인하고 결함 검출능을 결정하기 위함이다. 본 연구에서는, 실제 유체가속부식 손상 시험편의 엘보우 첫 번째 용접부와 두 번째 용접부의 진폭 감쇄비를 측정하기 위하여 3가지 검사 기법을 사용하였다. 연구 결과, 유체가속부식 손상을 검출하기 위한 최적의 검사 기법과 최소 결함 검출능을 도출하였다.

변압기 저압측 중성점 접지선의 누설전류 통합 감시에 관한 연구 (A Study on the Integrated Monitoring of a Leakage Current of the Grounding Wire of Neutral Point of the Low Voltage Side of Transformer)

  • 홍순석;박준열;이정은;최경한
    • 조명전기설비학회논문지
    • /
    • 제24권5호
    • /
    • pp.106-113
    • /
    • 2010
  • 누설전류를 그대로 방치할 경우 전기로 인한 감전, 화재 등 여러 가지 재해요인이 될 수 있으므로 상시감시가 필요하다. 그러나 변전소 관리를 무인화 또는 순회점검으로 실시하는 곳이 대부분이므로 상시 감시에 어려움이 있어 사고발생시 원인을 즉시 제거하지 못하고 누설전류에 의해 비상발전기의 OCGR이 작동되어 ACB가 차단될 경우 비상발전기의 가동이 중지되는 문제점이 있다. 이러한 문제점을 방지하기 위해 변압기 저압측 중성점 접지선으로 귀환하는 누설전류를 실시간 모니터링할 수 있는 변압기 누설전류 통합 감시 장치를 제안하였다. 따라서 본 논문에서는 저압전로와 기기의 절연이 열화 또는 파괴되어 흐르는 누설전류의 영향을 시뮬레이션을 통해 알아보고 사례연구를 통해 통합 감시 장치의 우수성을 검증하였다.