• Title/Summary/Keyword: Insulation Degradation

Search Result 230, Processing Time 0.026 seconds

The Effects on the Crystal Structure of LDPE thin film exposed Radiation (방사선이 LDPE박막의 결정구조에 미치는 영향)

  • 강전홍;김한준;유광민;박강식;김종석;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.181-184
    • /
    • 2000
  • LDPE pelet is distilled to make 0.5 Wt% solutions and fabricated as LDPE thin film by dropping the solution onto glass substrate, and then annealed the film to be crystalline. The structure is observed as crystalline regions and non-crystalline regions. The crystalline region is exposed at radiation and as the result, there appeared degradation at the total region of the crystal structure. It is considered therefore that radiation exposure at the crystal structure is badly effected on insulation property and lifetime of materials.

  • PDF

The Change of Electrical Properties on Silicone Rubber Contained ATH under Cyclic Aging(I) (ATH를 첨가한 실리콘고무의 반복열화에 따른 전기적 특성변화(I))

  • Oh, Tae-Seung;Lee, Chung;Kim, Ki-Yup;Park, Soo-Gil;Ryu, Boo-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.258-261
    • /
    • 2001
  • In this paper, aging characteristics of silicone rubber used for outdoor insulation have been investigated with regards to salt fog condition and heat aging effect. We look over the change of properties of silicone rubber in salt fog chamber with average leakage current monitoring for observing the transformation of surface degradation properties of silicone rubber with different ATH(alumina trihydrate, Al$_2$O$_3$$.$3H$_2$O) filler contents. Surface resistivity, SEM(Scanning Electro Microscope) were measured.

  • PDF

Discrimination of insulation defects using a neural network (신경회로망을 이용한 절연 결함의 판별)

  • 최재관;김재환;김성홍;윤헌주;박재준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.381-384
    • /
    • 1997
  • This paper describes the method of diagnosing the degradation by void defects of insulator inside in operation. Needle-shape void specimens, made from LDPE, were used to generate an electrical tree under ac voltage. The method uses a neural network system with input signal of AE patterns. AE pattern consists of the pulse count and average amplitude according to the phase angle. After the learning process was over, unknown emission patterns were put into the network. It was shown that the network discriminates the void deflects well. The effectiveness of the neural network system for partial discharge recognition was shown.

  • PDF

The Evaluation of Flashover Characteristics of Polymer Insulators with Tracking Wheel Test (트래킹 휠 시험에 의해 열화된 폴리머애자의 섬락특성 평가)

  • Lee, Byung-Sung;Han, Jae-Hong;Yoon, Tae-Sang;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.82-85
    • /
    • 2000
  • Polymeric composite insulators are used for outdoor insulation. However, our knowledge about their long-term performance in an outdoor environment is still very limited. The electrical stress caused the surface of these insulators to become degradation. In order to evaluate the tracking resistance of polymer insulators, we performed the tracking wheel test which is recommended by CEA LWIWG-01. And the flashover voltage tests were conducted for understanding electrical characteristics after tacking wheel test. Also, these insulators are studied by characterization methods such as contact angle measurement, SEM, etc.

  • PDF

A Study on the UV Degradation characteristics of FRP by Plasma Surface Modification (플라즈마 표면개질에 따른 FRP의 자외선 열화 특성에 관한 연구)

  • Lim, K.B.;Lee, S.H.;You, D.H.;Hwang, M.W.;Lim, E.C.;Cho, G.S.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1544-1546
    • /
    • 2003
  • In this study, composite materials were put to dry interfacial treatment by use of plasma technology. It has been presented that the optimum parameters for the best wettability of the samples at the time of generation of plasma were oxygen atmosphere, 0.1 torr of system Pressure, 100 W of discharge power, and 3 minutes of discharge time. The decrease in surface potential of charged samples by corona discharge indicates that the amount of accumulated electrical charges reduces and the charges that have been injected lessen rapidly when the duration of UV irradiation increases. The surface resistivity and the tensile strength of plasma treated samples, a longer UV irradiation time resulted in decreased insulation.

  • PDF

Electrical insulation characteristics with simulated electrode system of HTS (HTS pancake 코일을 모의한 전극계에서의 전기절연 특성)

  • Joung, Jong-Man;Baek, Seung-Myeong;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.58-63
    • /
    • 2002
  • For the experiment the four types of spacer were distinguished by arrangement. The flashover characteristic on each types of spacer was investigated and the flashover phenomena were observed to understand breakdown mechanism in liquid nitrogen($LN_{2}$). The spacer should be placed interior coil as an insulator, a cooling channel and s supporter of structures. The simulated electrode used in the experiment was made from five turns of HTS tape. Experimental results revealed that multi-layer and barrier effects did work well in Air but did not in $LN_{2}$. These result suggested that the flashover in LN2 caused by the bubbles due to partial discharge at micro gap, g. The flashover characteristics decreased to 70% when g is 0.2 mm. The degradation was improved by even treatment on surface of coil electrode.

  • PDF

Deterioration Analysis of Electric Systems in Diesel Electric Locomotives (디젤전기기관차 전기장치 노후도 평가)

  • Kim, Jeong-Guk;Baek, Seung-Koo;Lee, Chang-Young;Kwon, Sung-Tae;Kwon, Seok-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1213-1219
    • /
    • 2008
  • The deterioration analysis of electric systems in diesel electric locomotives, which were used for over 30 years, was performed to understand current wear and safety information. The electric systems include electric generation, traction motors, control units, high-voltage cables, and wires. In this investigation, various types of performance testing, such as insulation resistance measurement and degradation tests, were conducted to assess the degree of current deterioration. Moreover, an infrared camera was employed to verify abnormal heating in cables and wires. In this paper, the new techniques for evaluation of deterioration in electric systems have been introduced.

  • PDF

Fundamental Study of Degradation Diagnosis using AE Signals with Void Discharge in XLPE Insulation (XLPE 절연체의 트리 채널내 보이드방전에 의한 AE신호로 절연열화 검출 기법 연구)

  • Lee, Sang-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.75-80
    • /
    • 2006
  • In this paper, to detect and observation the void discharges pulse signal, AE signals and tree growth characteristics in case the high voltage is applied to a XLPE sample for a power cable. We also examined the partial discharge current pulse and AE signals with the increase of the applied voltage in XLPE insulation. The experimental results show that a branch-type tree grows in the presence of the voids, and a bush-type tree grows in the absence of the voids in both samples. A rate of tree growth increases abruptly in proportional to the deterioration time in the presence of the of the voids, but in the absence of the voids, a rate of tree growth decreases as time goes by and finally a breakdown occurs. The frequency band of AE signals that are generated from the partial discharges in a XLPE sample, one of solid dielectric materials, is about 1.0[MHz].

Assessment of Pipe Wall Loss Using Guided Wave Testing (유도초음파기술을 이용한 배관 감육 평가)

  • Joo, Kyung-Mun;Jin, Seuk-Hong;Moon, Yong-Sig
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.295-301
    • /
    • 2010
  • Flow accelerated corrosion(FAC) of carbon steel pipes in nuclear power plants has been known as one of the major degradation mechanisms. It could have bad influence on the plant reliability and safety. Also detection of FAC is a significant cost to the nuclear power plant because of the need to remove and replace insulation. Recently, the interest of the guided wave testing(GWT) has grown because it allows long range inspection without removing insulation of the pipe except at the probe position. If GWT can be applied to detection of FAC damages, it will can significantly reduce the cost for the inspection of the pipes. The objective of this study was to determine the capability of GWT to identify location of FAC damages. In this paper, three kinds of techniques were used to measure the amplitude ratio between the first and the second welds at the elbow area of mock-ups that contain real FAC damages. As a result, optimal inspection technique and minimum detectability to detect FAC damages drew a conclusion.

A Study on the Integrated Monitoring of a Leakage Current of the Grounding Wire of Neutral Point of the Low Voltage Side of Transformer (변압기 저압측 중성점 접지선의 누설전류 통합 감시에 관한 연구)

  • Hong, Soon-Seuk;Park, Joon-Yeol;Lee, Jung-Eun;Choi, Kyung-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.106-113
    • /
    • 2010
  • If leakage current is neglected, it can become a cause for disasters such as electric shock and fire, therefore a continuous monitoring is necessary. However in most cases, because management of substations is performed by unmanned systems, or walk-around inspections, continuous monitor is difficult. So when an accident occurs and the cause is not immediately resolved causing the emergency generator's OCGR getting activated by the leakage current that in turn cut off the ACB, the emergency generator may stop working. To prevent such a problem, a real-time integrated monitoring system for monitoring the leakage current returning to the grounding wire of neutral point of the low voltage side of transformer is proposed. Therefore in this paper, the effects of flow of leakage current, which is caused by insulation degradation phenomena or insulation destroy phenomena, were identified by simulation. And through cases studies; the excellence of integrated monitoring system was verified.