• Title/Summary/Keyword: Insulation Assessment

Search Result 125, Processing Time 0.029 seconds

Electrical Life Time Constant Estimation of Ceramic Element for Sensor (센서용 세라믹 소체의 전기적 수명지수 산출)

  • Jeong, Joo-Young;Kang, Dong-Sik;Sun, Jong-Ho;Heo, Jong-Cheol;Choo, Young-Bae;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1995-1999
    • /
    • 2009
  • A partial discharge(PD) measurement is a very effective method to assess the insulation condition of high-voltage machines. It is necessary that the life time of the on-line PD measurement sensor is assessed. Therefore, the electrical life time assessment method of ceramic element was reviewed in order to estimate the life time of the on-line PD measurement sensor. The samples were prepared according to the reviewed method and were tested at 8kV, 9kV and 10kV. Based on the obtained results, the life time constant is shown above 59. Also, it is assumed that the estimated life time constant can be used to anticipate the life time and to assess the conformity of the on-line PD measurement sensor.

An On-line Insulation Quality Assessment for AC Machine Stator Windings based on Differential Leakage Current Measurement (절연 누설 전류 측정을 이용한 운전 중인 교류 전동기의 고정자 절연 상태 진단)

  • Cho, Jin-Tae;Lee, Sang-Bin
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.356-357
    • /
    • 2007
  • 본 논문은 3상 교류기기 고정자 권선의 주절연과 상간 절연의 절연 상태 진단에 대한 연구이다. 각 상의 차동 누설 전류 측정을 이용하여 교류기기의 운전 중에 절연 상태를 나타내는 인자인 커패시턴스와 Dissipation Factor($tan{\delta}$)를 계산한다. 이를 위해 오프라인과 온라인 테스트를 위한 3상 절연 시스템 모델을 유도하고, 알고리즘을 통해 각 상의 고정자 권선의 주절연과 상간 절연의 상태를 나타내는 인자를 정량화한다. 15hp의 유도 전동기를 이용하여 주절연과 상간 절연의 고의적인 열화 아래 실험을 하였다.

  • PDF

Assessment of Insulation Condition for Generator Rotor Windings (발전기 회전자 권선의 건전성 평가)

  • Lee, Young-Jun;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.59-60
    • /
    • 2006
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line shorted-turn diagnosis system. The permanent flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.

  • PDF

Assessment of Vibration Transmissibility for Prediction of Heavy Floor Impact Sound (중량 바닥충격음 예측을 위한 진동 전달률 산정 연구)

  • 김하근;김명준;오양기
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.6
    • /
    • pp.415-422
    • /
    • 2003
  • In an apartment buildings, the floor Impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. To set the optimum design for sound insulation, it is necessary to suggest the useful tools or technique that predict the floor impact sound. The purpose of this study is to suggest the supplementary formula(equation) and constant k considering vibration transmissibility in order to predict more precisely heavy floor impact sound by Impedance Method that have been briskly studied in Japan from comparing the measured values with the predicted values. The analyzed results had showed that if the damping material was glass wool or rubber, k=5 was proper and if the damping material was polystyrene foam, k>5 was desirable.

Development of an Adaptive Neuro-Fuzzy Techniques based PD-Model for the Insulation Condition Monitoring and Diagnosis

  • Kim, Y.J.;Lim, J.S.;Park, D.H.;Cho, K.B.
    • Electrical & Electronic Materials
    • /
    • v.11 no.11
    • /
    • pp.1-8
    • /
    • 1998
  • This paper presents an arificial neuro-fuzzy technique based prtial discharge (PD) pattern classifier to power system application. This may require a complicated analysis method employ -ing an experts system due to very complex progressing discharge form under exter-nal stress. After referring briefly to the developments of artificical neural network based PD measurements, the paper outlines how the introduction of new emerging technology has resulted in the design of a number of PD diagnostic systems for practical applicaton of residual lifetime prediction. The appropriate PD data base structure and selection of learning data size of PD pattern based on fractal dimentsional and 3-D PD-normalization, extraction of relevant characteristic fea-ture of PD recognition are discussed. Some practical aspects encountered with unknown stress in the neuro-fuzzy techniques based real time PD recognition are also addressed.

  • PDF

Utilizability of Shell Powder as Wall Coatings for Thin Textured Finishes (건축용 벽 바름재로서 패각분말의 활용성 연구)

  • Jeon, Ji-Hyeon;Kook, Chan
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.33-40
    • /
    • 2007
  • 0.4 Million tons of shell powder have been disused as waste in KOREA and caused severe environmental pollution though shell powder can be utilized in real life for many ways. It is impending problem to recycle shell powder as it requires high expense for burying and temporary outside heap and causes severe environmental pollution being a main factor of ocean waste. To suggest the basic data for development of eco-friendly and high-function Wall Coatings Thin Textured Finishes, a wall coating sample was applied to indoor walls of a mock-up and temperature and humidity were measured to assess the thermal performance of it, and a survey of preference for the color sense and feel of the materials with a movie of specimens. The results of the study are following; 1) High insulation performance is shown from the assessment result of the room polystyrene board adhered on the walls then high humidity controlling performance is shown from that of the room polystyrene board coated by shell powder. This point out that shell powder has superiority for humidity controlling. 2) The result of thermal and humidity assessment shows that shell powder makes up for thermal conduction of the polystyrene board and same result can be expected from the assessment with materials which has similar thermal characteristics with polystyrene.3) Ranking of preferred specimens is; 1st Case 13, 2nd Case 17, 3rd Case 16, and 4th Case 12. Preferred shell powder was the ark shell. Preferred powder for plaster was the powder mixed with that sifted by 0.8mm, 100mesh and 40mesh, and for spray was the fine powder mixed with that sifted by 100mesh and 40mesh.

Assessment of Pipe Wall Loss Using Guided Wave Testing (유도초음파기술을 이용한 배관 감육 평가)

  • Joo, Kyung-Mun;Jin, Seuk-Hong;Moon, Yong-Sig
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.295-301
    • /
    • 2010
  • Flow accelerated corrosion(FAC) of carbon steel pipes in nuclear power plants has been known as one of the major degradation mechanisms. It could have bad influence on the plant reliability and safety. Also detection of FAC is a significant cost to the nuclear power plant because of the need to remove and replace insulation. Recently, the interest of the guided wave testing(GWT) has grown because it allows long range inspection without removing insulation of the pipe except at the probe position. If GWT can be applied to detection of FAC damages, it will can significantly reduce the cost for the inspection of the pipes. The objective of this study was to determine the capability of GWT to identify location of FAC damages. In this paper, three kinds of techniques were used to measure the amplitude ratio between the first and the second welds at the elbow area of mock-ups that contain real FAC damages. As a result, optimal inspection technique and minimum detectability to detect FAC damages drew a conclusion.

A Simple Metric for Assessing the Severity of Partial Discharge Activity Based on Time-Sequence-Analysis-Discharge Level Patterns

  • Stewart Brian G;Yang Lily;Judd Martin D;Reid Alistair;Fouracre Richard A
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.313-318
    • /
    • 2006
  • This paper introduces a partial discharge (PD) severity metric, S, based on the evaluation of time-sequence PD data capture and resulting Time-Sequence-Analysis Discharge (TSAD) level distributions. Basically based on an IEC60270 measurement technique, each PD event is time stamped and the discharge level noted. By evaluating the time differences between a previous and subsequent discharge, a 3D plot of time-sequence activity and discharge levels can be produced. From these parameters a measurement of severity, which takes into account dynamic or instantaneous variations in both the time of occurrence and the level of discharge, rather than using standard repetition rate techniques, can be formulated. The idea is to provide a measure of the severity of PD activity for potentially measuring the state of insulation within an item of plant. This severity measure is evaluated for a simple point-plane geometry in $SF_{6}$ as a function of gap distance and applied high voltage. The results show that as the partial discharge activity increases, the severity measure also increases. The importance of future investigations, quantifications and evaluations of the robustness, sensitivity and importance of such a severity measurement, as well as comparing it with typical repetition rate assessment techniques, and other monitoring techniques, are also very briefly discussed.

DGA Gases related to the Aging of Power Transformers for Asset Management

  • Kweon, Dongjin;Kim, Yonghyun;Park, Taesik;Kwak, Nohong;Hur, Yongho
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.372-378
    • /
    • 2018
  • Life management technology is required as the failure risk of aged power transformers increases. Asset management technology is developed to evaluate the remaining life, establish the replacement strategies, and decide the optimal investment based on the reliability and economy of power transformers. The remaining life assessment uses data such as installation, operation, maintenance, refurbishment, and failure of power transformers. The optimal investment also uses data such as maintenance, outage, and social costs. To develop the asset management system for power transformers, determining the degradation parameters related to the aging of power transformers and evaluating the condition of power transformers using these parameters are important. In this study, since 1983, 110,000 Dissolved Gas Analysis (DGA) data have been analyzed to determine the degradation parameters related to the aging of power transformers. The alarm rates of combustible gases ($H_2$, $C_2H_2$, $C_2H_4$, $CH_4$, and $C_2H_6$), TCG, CO, and $CO_2$ were analyzed. The end of life and failure rate (bathtub curve) of power transformers were also calculated based on the failure data from 1981 to 2014. The DGA gases related to discharge, overheating, and insulation degradation were determined based on alarm and failure rates. $C_2H_2$, $C_2H_6$, and $CO_2$ were discharge, oxidation, and insulation degradation parameters related to the aging of power transformers.

Research on Fire Safety of Mortar-Containing Waste Tire Powders and Flame Retardant (폐타이어 분말과 난연제가 혼입된 모르타르의 화재안전에 관한 연구)

  • Park, Jeong-Jin;Son, Ki-Sang
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.12-17
    • /
    • 2010
  • The purpose of this study is to determine how effectively waste tire recycled material mixed with flame retardant work in combating fire. As discovered in the previous study, waste tire mixed with cement mortar has more insulation capacity. However, this mortar is weak against fire. Therefore flame retardant, with a specific proportional mix, will be added to increase its fire prevention capacity. Tests will be made in accordance with ISO 5657 procedures for measuring fire ignition time, flame and shape variation of test pieces at the Building Material Test Institute. The test piece will be set up with horizontal levels having a constant radiation heat of $1{\sim}5W/cm^2$. Temperature transfers and increases from the surface into the interior. Combustible gases result due to pyrolysis, and regular contact is maintained between the fire source and the center of the test piece for assessment purposes. Ignition has not been occurred without adding retardant meaning that there is almost no possibility of ignition of waste tire particle. This fact can be considered as fire load to appreciate a volume of combustion materials. Flame is not occurred due to heat-absorbing effect by adding non-organic series retardant into waste tire particle. Conclusions have been summarized as follows; 1) Combustion of building material can be decreased by adding retardant to waste tire-mixing mortar. But compressive strength and insulation capacity of the material should be measured later. 2) Firing prevention and ignition are main points of building fire. Reasonable fire engineering assessment of interior material should be made for establishing effective disaster prevention system.