Abstract
A partial discharge(PD) measurement is a very effective method to assess the insulation condition of high-voltage machines. It is necessary that the life time of the on-line PD measurement sensor is assessed. Therefore, the electrical life time assessment method of ceramic element was reviewed in order to estimate the life time of the on-line PD measurement sensor. The samples were prepared according to the reviewed method and were tested at 8kV, 9kV and 10kV. Based on the obtained results, the life time constant is shown above 59. Also, it is assumed that the estimated life time constant can be used to anticipate the life time and to assess the conformity of the on-line PD measurement sensor.
Keywords
Partial; Life time constant; Ceramic sensor; Accelerated aging;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
Times Cited By SCOPUS : 1
연도 인용수 순위
1 Zhu, H., Green, V., Sasic, M., and Halliburton, S.: 'Increased Sensitivity of Capacitive Couplers for In-service PD Measurement in Rotating Machines', IEEE Transactions on Energy Conversion, 1999, 14, (4), pp. 1184-1192   DOI   ScienceOn
2 H. Yoshida et al., 'Insulation Diagnosis for rotating machine insulation', IEEE Trans. on EI-21 No.6, Dec. 1986
3 D. I. YANG, et al., 'RELIABILITY OF EPOXY SPACER FOR EHV-CLASS GAS INSULATED SWITCHGEAR', IEEE 7th International Conference on Solid Dielectrics, pp 121-124, June. 2001
4 Culbert, I.M., Dhirani, H., and Stone, C.C. 'Handbook to Assess the Insulation Condition of Large Rotating Machines' (Power Plant Electrical Reference Series vol. 16, EPRI publication EL -5036, 1989)
5 Dong-Sik Kang, et al., 'Characteristcs of Ceramic Coupler for On-line Partial Discharge Measurement in High Voltage Rotating Machines', Trans. KIEE. Vol. 51C, No.5, pp 205-212, May. 2002
6 Y. S. Cho, et al., 'Characteristics of polymer insulator materials: Voltage-lifetime characteristics of DGEBA/MDNSN system', Materials Chemistry and Physics 66, pp 70-76, 2000   DOI   ScienceOn
7 J. Y. Jeong, et al., 'Assessment of 23kV Capacitive Coupler for On-line Partial Discharge Measurements', Journal of Electrical Engineering & Technology Vol. 4. No.1, pp 123-130, 2009   DOI