• Title/Summary/Keyword: Insulating transformer

Search Result 166, Processing Time 0.032 seconds

A Study on the Insulating Properties of Pressboard for High Voltage Transformer Applied the Mold of Eddy Current Loss (와전류 손실을 적용한 금형으로 제조된 초고압 변압기의 프레스보드의 절연 특성 연구)

  • Suh, Wang-Byuck
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.8
    • /
    • pp.508-512
    • /
    • 2015
  • Some insulating materials are tested and analyzed with variables to obtain the reliable pressboard which is located to core and coil of high voltage transformer. The high voltage transformer is used in electrical power system and operating reliability. Optimization possibility of pressboard shape including electrical insulation performance could be achieved by analysis simulation. Using insulating pressboard, which is made by mold applied eddy current loss, it could be measured the influences of moisture content for electrical properties. As a result, it is to contribute to improve the performance and ensure the reliability of the pressboard by investigating electrical strength according to the variation oil temperature. In addition pressboard thickness is important design factor to ensure electrical strength in high voltage transformer.

A study on the development of diagnosis device for pole transformer deterior (주상변압기 열화진단장치 개발에 관한 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Kim, Young-Chun;Kim, Hun;Min, Kyung-Rae;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1079-1081
    • /
    • 1998
  • This paper describes the dissipation factor measuring device for insulating oil in operating pole transformer by DSP(digital signal processor). After applying voltage to the sensor which is installed in a transformer, acquire source voltage and current of sensor using FFT techniques, then we could evaluate the dissipation factor of insulating oil. To improve measuring accuracy and processing speed, we use TMS320C31 DSP, FFT and data analysis techniques. Also we suggest deterioration criterion of insulating oil and compared the developed diagnosis device with schering bridge on deteriorated insulating oil. The result of this paper show that the developed measuring device can be used as diagnosis device for the pole transformers.

  • PDF

A new method for measuring the degradation level of transformer insulating oil in use (변압기 절연유의 열화 검출에 관한 연구)

  • Bae, Jin-Ho;Chon, Young-Kap;Kang, Young-Ku
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.214-219
    • /
    • 1988
  • Aging process in transformer insulating oil is studied by measuring the leakage current in ceramic sensor. the current of a sensor developed if this paper shows a close relationship with the acid value and the breakdown voltage of the transformer oil. The sensor has excellent physico-chemical reaction to the oil and stable adsorption of conductive impurities. Therefore the experimental data show good reproducibility. From the detailed analysis of the leakage current, it may be proposed that the condition of transformer insulating oil in service can be checked portably.

  • PDF

재질이 변압기 절연유의 유동대전에 미치는 영향

  • 곽희로;김재철;김두석;권동진
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.3
    • /
    • pp.72-77
    • /
    • 1991
  • In a large power transformer, insulating oil is forced to circulate for cooling the heat generated by the losses within windings and core. When insulating oil flows and rubs against various materials, such as insulating paper or core, the electrostatic charges are separated at the interface of the oil and the solid material. This paper considers the streaming electrification of various materials used in the transformer. In this study, we show that a solid material such as paper is negatively charged. On the other hand, a solid material such as core is positively charged.

  • PDF

Dissolved Gas Analysis of Environment-Friendly Vegetable Insulating Oils (친환경 식물성 절연유의 유중가스 분석)

  • Choi, Sun-Ho;Kim, Kwan-Sik;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.4
    • /
    • pp.238-243
    • /
    • 2015
  • The vegetable insulating oils are substitute for the mineral oil in power transformer. Vegetable insulating oils has higher flash/fire point and biodegradability than conventional mineral oils. In this paper, we investigated the dissolved gas analysis of vegetable oils. In the experiment, I had to accelerated aging under the same conditions mineral oil and vegetable oils. Accelerated aging proceeded to about 100% of the life of oil-filled transformer. In addition, we performed gas analysis of insulating oil of accelerated aging progress. The experiment results of the five gases was measured with the exception of Hydrogen and Acetylene. The mineral oil and vegetable oils gas is generated in a similar tendency depending on the accelerated aging. As a result, vegetable oils, can be dissolved gas analysis by method such as mineral oil.

Diagnostic techniques of aging deterioration of power transformer by insulating paper (절연지에 의한 전력용변압기 열화진단 기술)

  • Park, Hyun-Joo;Nam, Chang-Hyun;Yoon, Yeo-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.449-452
    • /
    • 2004
  • The life of power transformer is basically dependent on the aging deterioration of insulating paper. Analysis of insulating paper for its DP value or tensile strength requires removal of a few strips of paper but direct measurement of this properties is not practical for in-service transformers. For this reason furfural analysis by HPLC has gained increasing favor as a means of estimating degradation of insulating papers in power transformers and this paper reports on the analysis of data on the concentration of furfural in oil samples from about 50 power transformers and the case study. The data showed that furfural content can estimate more accurately aging characteristics compared to concentration of CO, $CO_2$. We expect that these results can be useful to predict the aging characteristics and life diagnosis of power transformers and further the study must be continued.

  • PDF

Problem considerations and expectations in applying vegetable oil to power transformer (식물성 절연유의 전력용 변압기 적용에 따른 문제점 고찰 및 전망)

  • Park, Hyun-Soo;Kim, Ji-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.184-186
    • /
    • 2009
  • In past, transformer connection study was concentrated on efficiency improvement and life time broadening. But environmental side began to become important recently. In existing, quick transaction of mineral oil used to insulation oil of transformer is possibility to be difficult and causes environmental pollution in case of was outpoured and there is worry of fire occurrence. Accordingly, nonflammable performance becomes many interest in excellent vegetable oil because ignition point is high than mineral oil and environment friendly material. But, vegetable oil is cooling of transformer and insulation problem of insulating paper for cause of insulation oil special quality. Therefore, in this paper, special quality of vegetable oil that there are being a lot of mineral oil and the latest interest examined about problem and consideration item to be solved to analyzed comparison and applies vegetable oil to transformer for electric power.

  • PDF

Development of Preventive Diagnosis Techniques for Transformer Oil by Capacitive Sensor (전기용량형 센서를 이용한 변압기 절연유 열화진단용 예방진단기법 개발)

  • Kim, Ju-Han;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2061_2062
    • /
    • 2009
  • Within serviced period of time in transformer, thermal stress is the most influential parameter affecting the aging behavior of an insulation system. The thermal stress on the insulation system may occur from operation in a high temperature environment due to Joule's heat at winding coils. This paper describes a development of capacitive sensor and preventive diagnosis techniques for electrical insulating oil, widely used for power and distribution transformer. To survey the dielectric properties of the virgin and used mineral insulating oil, we utilized the highly precise measuring system of KRISS. And the results were used to determine the design factors of the sensor. To evaluate diagnosis by the sensor, we performed accelerated aging test about insulating oils. The condition of aged specimens were investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor.

  • PDF

A Study on the Age Degradation Kinetics of Pole Transformer Oil (주상변압기 절연유의 경년열화반응 속도론에 관한 연구)

  • 남영우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.1
    • /
    • pp.99-105
    • /
    • 1997
  • In the paper, aging of insulating oil in pole transformer has been studied by performing accelerated thermal aging test. Dissolved gases were extracted by air bubbling method. Concentration of dissolved gases were modified by extraction ratio of each gases in insulating oil. Aging of insulating materials were proceeded by thermal degradation and oxidation reaction. Both of the reactions followed zeroch order kinetics. Formation rate equations for hydrocarbons, carbon oxides, and hydrogen were derived. It was conformed by gas analysis and UV-Visible spectrophotometric method that iron core and copper coil in pole transformer act as catalyst during the aging process.

  • PDF

Manufacture and Performance Evaluation of Insulating Transformer for surge protection under Electric Railway Environments (전기철도환경하에서의 서지방호용 절연변압기 제작 및 성능평가)

  • Lee, K.W.;Kim, M.Y.;Ohn, J.G.;Park, D.W.;Park, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.176-177
    • /
    • 2006
  • The main aim of the paper is the study of the surge voltages in electric railway signal security system. Hence these studies will provide means of introducing a suitable protective device insulating transformer. This influences the surge voltage interrupting capacity using surge arresters and bypass capacitors. This circuit can be used for investigating surge phenomenon in electric railway signal security system. In this paper a insulating transformer has been introduced for the reduction of surge voltages in the above circuit model and performance evaluation.

  • PDF