• Title/Summary/Keyword: Insulating Oil

Search Result 221, Processing Time 0.04 seconds

A Study on the Streaming Electrification in the Super-high Voltage Model Transformer (초고압 대용량 모델변압기의 유동대전 현상에 관한 연구(전압무인가))

  • 이덕출;박재윤
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.6
    • /
    • pp.619-625
    • /
    • 1991
  • Phenomena of streaming electrification of insulting oil(T.O) is studied where the oil is contacted with solid insulating materials when it is pumped through a circulating system in a large power transformer. The leakage current, the electrical potential at the neutral terminal point of the transformer and the surface electrical potential of the oil are investigated. And the leakage current from the neutral terminal point is measured as a function of a bias polarity applied to a transformer case to investigate the polarty of ion which is absorbed in the case at the interface between the case and oil. As a result, it is found that insulating materials, and it is suggested that the leakage current is the sum of the relaxation current by positive charge from insulating oil to the neutral terminal point and by electrification current from negative charge electrified by the contact with solid insulating materials.

  • PDF

A study on the effect of solid materials on the streaming electrification of insulating oil (절연유의 유동대전에 미치는 고체재질의 영향에 관한 연구)

  • 김용운;임헌찬;김영일;김영봉;이덕출
    • Electrical & Electronic Materials
    • /
    • v.7 no.3
    • /
    • pp.236-242
    • /
    • 1994
  • In this paper, the streaming electrification characteristics of insulating oil were examined when the oil is contacted with solid materials in a circulating system. The streaming current($I_s$) increases with increasing oil velocity and temperature, and electrification properties depend on species of metal materials. $I_s$ in the gauze-contained electrification apparatus increases with increasing oil temperature below the temperature of 43[>$^{\circ}C$], but decreases above 43[>$^{\circ}C$]. On the other hand, $I_s$ is positive electrificated for the pipe of Fe, Cu, while it is negative electrificated for Sus. When insulating oil flows through a car fuel filter, $I_s$ increases linearly with increasing oil temperature.

  • PDF

A Study on Suggestion of Insulating Oil Ageing Degree in Pole-Transformer by Absorbance (흡광도법에 의한 주상변압기 절연유의 열화판정기준 설정에 관한 연구)

  • Lee, Dong-Zoon;Jung, Jong-Uk;Kim, Kyung-Hwa;Kwak, Hee-Ro;Yun, Yong-Ja
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1851-1853
    • /
    • 1996
  • In this paper the criteria for insulating oil condition of pole transformer were suggested by applying the UV-Visible spectrophotometric method. Ageing of insulating oil caused the change in absorbances of oil os well os the deterioration of electrical properties of oil. By comparing the electrical properties such as $tan{\delta}$ and breakdown voltage with the UV-Visible absorbances of oil, criteria for absorbance values determining oil condition were established. This UV-Visible spectrophotometric method might be applied in ageing analysis of oil and be expected to replace the current method.

  • PDF

재질이 변압기 절연유의 유동대전에 미치는 영향

  • 곽희로;김재철;김두석;권동진
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.3
    • /
    • pp.72-77
    • /
    • 1991
  • In a large power transformer, insulating oil is forced to circulate for cooling the heat generated by the losses within windings and core. When insulating oil flows and rubs against various materials, such as insulating paper or core, the electrostatic charges are separated at the interface of the oil and the solid material. This paper considers the streaming electrification of various materials used in the transformer. In this study, we show that a solid material such as paper is negatively charged. On the other hand, a solid material such as core is positively charged.

  • PDF

A study on Design for Multi-step Filter to improve the Efficiency of Insulating Oil (절연오일의 효율을 향상하기 위한 다단계 필터 설계에 관한 연구)

  • 권병무;기현철;정우성;최창주;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.155-158
    • /
    • 1999
  • Because the traditional filters have many demerits, multi-step electric oil filter have manufactured the efficiency of insulating oil to improve. Therefore, the function of oil filter to improve based on my experience and know-how about my job. Through this study have obtained many merits. The efficiency of insulating oil is improved. The waste oil reused in repair works of the damaged transformer. Multi-step filter is shortening the working time and safety. it is handy for use and movement. This study lengthen the expected life span of filter. The improvement of oil filter bring about elevation of productivity.

  • PDF

A Study on the Streaming Electrification and Static Charge Elimination of Insulating Oil on Pipe Materials. (파이프 재질에 따른 절연유의 대전및재전에 관한 연구)

  • Kim, Y.W.;Cho, Y.K.;Shin, Y.D.;Jeong, H.D.;Lee, D.C.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.05a
    • /
    • pp.72-75
    • /
    • 1993
  • The characteristic of streaming electrification and static charge diminution in Cu, Fe and Sus pipes were investigated. The Cu and Fe pipes are charged positively, whereas the Sus pipes are charged negatively. Electrification rate in Cu and Fe pipes increases with increasing a pipe length for no-charged insulating oil. The electrification rate in Cu and Fe pipes abruptly increase with increasing the temperature and flow rate of insulating oil but decrease in Sus pipes. The current flows as a direction of insulating oil in all pipes.

  • PDF

A Study on the Effect of Surfactants on the Streaming Electrification of Insulating Oil (절연유의 유동대전현상에 미치는 계면활성제의 영향에 관한 연구)

  • Chung, K.H.;Lim, K.B.;Kim, Y.W.;Park, J.Y.;Joe, K.S.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1534-1536
    • /
    • 1997
  • In this paper, the streaming electrification phenomena of insulating oil by metal filters and the charge elimination method were investigated. When BTA and surfactant is molten in insulating oil, BTA appear the prevention of electrification from about 5ppm and surfactant (SP-S10, SP-S30) appear the prevention of electrification from about 20ppm. BTA increase the conductivity of insulating oil but surfactant and antioxidant(DBPC) isn't affect that.

  • PDF

A study on the development of diagnosis device for pole transformer deterior (주상변압기 열화진단장치 개발에 관한 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Kim, Young-Chun;Kim, Hun;Min, Kyung-Rae;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1079-1081
    • /
    • 1998
  • This paper describes the dissipation factor measuring device for insulating oil in operating pole transformer by DSP(digital signal processor). After applying voltage to the sensor which is installed in a transformer, acquire source voltage and current of sensor using FFT techniques, then we could evaluate the dissipation factor of insulating oil. To improve measuring accuracy and processing speed, we use TMS320C31 DSP, FFT and data analysis techniques. Also we suggest deterioration criterion of insulating oil and compared the developed diagnosis device with schering bridge on deteriorated insulating oil. The result of this paper show that the developed measuring device can be used as diagnosis device for the pole transformers.

  • PDF

Application of UV-Vis Spectroscopic Analysis for Transformer Insulating Paper Degradation (UV-Vis 분광분석에 의한 전기변압기 내 절연지 열화도 측정)

  • Kong, Hosung;Han, Hung-Gu
    • Tribology and Lubricants
    • /
    • v.35 no.3
    • /
    • pp.151-157
    • /
    • 2019
  • Insulated oil degradation produces charged by-products, such as acids and hydro-peroxides, which tend to reduce the insulating properties of the oil. In this study, UV-vis spectroscopy measurement technology is developed and experimentally compared with other measurement methods, such as the titration method and IR spectroscopy, to validate its ability to monitor the degradation of electrical insulating paper. The degradation characteristics of the insulating paper are appropriately represented through various types of measurement methods, such as the Tan (delta) method, $CO_2$ gas production measurement, the titration method, and IR spectroscopy. The results are demonstrated to be well comparable to a change in the fluorescence emission ratio (FER), which is defined as the shift in fluorescence intensity in the measured wavelength range, and also to the chromatic ratio, which is defined as a color shift to longer wavelength ranges. The results also show that, by using UV-vis spectroscopy, it is possible to detect the degradation of the insulating paper. This study suggests that UV-vis spectroscopy can be applied as an alternative to high-performance liquid chromatography, which is the internationally recognized measurement technology for cellulose paper degradation. The FER detector is also verified to be useful as an effective condition-monitoring device for power transformers.

Analysis on the Temperature Distribution Characteristics of Insulating oil of Transformer Using the Vegetable oil and Mineral oil (식물성 절연유와 광유가 사용된 유입변압기의 온도분포 특성)

  • An, Jung-Sik;Shim, Meoung-Seop;Jung, Joong-Il;Kim, Nam-Ryul;Huh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1215_1216
    • /
    • 2009
  • Most transformer use insulating and cooling fluids derived from petroleum crude oil, but mineral oil is some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Three transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Temperature of vegetable oil transformers was similar to temperature of mineral oil transformer in the same design at 80% load and above.

  • PDF