• 제목/요약/키워드: Instrumentation device

검색결과 168건 처리시간 0.023초

Automatic Wood Species Identification of Korean Softwood Based on Convolutional Neural Networks

  • Kwon, Ohkyung;Lee, Hyung Gu;Lee, Mi-Rim;Jang, Sujin;Yang, Sang-Yun;Park, Se-Yeong;Choi, In-Gyu;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권6호
    • /
    • pp.797-808
    • /
    • 2017
  • Automatic wood species identification systems have enabled fast and accurate identification of wood species outside of specialized laboratories with well-trained experts on wood species identification. Conventional automatic wood species identification systems consist of two major parts: a feature extractor and a classifier. Feature extractors require hand-engineering to obtain optimal features to quantify the content of an image. A Convolutional Neural Network (CNN), which is one of the Deep Learning methods, trained for wood species can extract intrinsic feature representations and classify them correctly. It usually outperforms classifiers built on top of extracted features with a hand-tuning process. We developed an automatic wood species identification system utilizing CNN models such as LeNet, MiniVGGNet, and their variants. A smartphone camera was used for obtaining macroscopic images of rough sawn surfaces from cross sections of woods. Five Korean softwood species (cedar, cypress, Korean pine, Korean red pine, and larch) were under classification by the CNN models. The highest and most stable CNN model was LeNet3 that is two additional layers added to the original LeNet architecture. The accuracy of species identification by LeNet3 architecture for the five Korean softwood species was 99.3%. The result showed the automatic wood species identification system is sufficiently fast and accurate as well as small to be deployed to a mobile device such as a smartphone.

NI-ELVIS를 활용한 센서계측공학의 실습교육 사례 (Application of practical education program of sensor instrumentation engineering using NI-ELVIS)

  • 이병렬;이용희
    • 한국실천공학교육학회논문지
    • /
    • 제3권1호
    • /
    • pp.76-83
    • /
    • 2011
  • 본 논문에서는 센서공학분야의 실습교육에 NI-ELVIS(National Instrument Educational Laboratory Virtual Instrumentation Suite)를 활용하는 방안을 제시하였다. ELVIS는 LabView 기반의 계측시스템 설계와 프로토타이핑 환경을 제공하는 개발 플랫폼을 지칭한다. ELVIS는 가상 계측장치와 다기능 데이터 수집 장치(DAQ) 및 벤치탑 워크스테이션, 프로토타이핑보드 등으로 구성되어 있기 때문에 사용자가 의도하는 다양한 형태의 계측시스템을 PC에서 소프트웨어적으로 구성할 수 있다. 따라서 고가의 계측 장비를 이용하지 않고도 전기전자 분야의 효과적인 실험 실습 교육을 진행할 수 있다는 장점이 있다. 특히 센서계측공학의 경우 센서 기술, 전기전자공학, 신호처리, 데이터 분석 등 다양한 분야가 혼합된 영역임에도 복잡한 실험 장치에 의존하지 않아도 실습교육에 활용이 가능하다. 본 논문에서 제시한 계측공학 실습교육에서의 적용 외에도 전기전자 실험이 필요한 다양한 교과목에 높은 학습효과를 기대할 수 있다.

  • PDF

정전류와 부 열저항 특성을 갖는 AC Direct Driver를 이용한 LED 형광등 개발 (Design of a AC driver with constant current and negative temperature resistance for a LED lamp)

  • 김현조;손경민;김민;김관형;변기식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.382-384
    • /
    • 2013
  • LED는 일반 백열등에 비해 훨씬 밝으면서도 저전력이라는 장점을 지니고 있다. 이에 기존 형광등이 지니는 효율적, 환경적 문제점을 개선하기 위해 LED형광등의 개발과 상용화가 이루어 졌다. LED는 형광등과 달리 극성을 지니는 단방향성 소자로 교류전원을 직접 쓸 수 없기 때문에 전원공급장치를 필요로 한다. 이 전원공급장치는 부피가 크고 가격이 비싸기 때문에 유지비용면에서 일반 형광등에 비해 기능성이 떨어진다. 본 연구에서는 이 전원공급장치를 대신하여 간략하게 AC전원을 정류하고, 전압변동에 따른 전류변화로 인한 빛의 밝기가 변하는 현상을 없애기 위해 정전류로 제어할 수 있는 회로를 구성하고 이를 LED모듈과 구분하여 Plug in/out 방식의 교체형 모듈로 구성하여 유지보수에 있어 저렴하고 손쉬운 교체가 가능한 소자개발방법을 제안하고자 한다.

  • PDF

근관형성 기구 및 방법에 따른 근관 형태의 변화 (CHANGES IN ROOT CANAL CONFIGURATION USING DIFFERENT FILE TYPES AND TECHNIQUES)

  • 허영주;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.291-304
    • /
    • 1997
  • The purposes of this study were to evaluate the changes in root canal configuration with canal instrumentation using different file types and techniques and to investigate most appropriate instrumentation technique in maintaining the original canal configuration with different file types. Fifty curved mesiobuccal or distobuccal canals of extracted human maxillary molar teeth were instrumented using a step-back technique with stainless steel K-files or nickel-titanium K-files, a crown-down pressureless technique with stainless steel K-files or nickel-titanium K-files and nickel-titanium engine-driven files. Radiographs were taken before and after instrumentation using a specially designed device that allowed for the pre-and postinstrumentation canals to be taken with the same X-ray angulation. Magnified X-ray images on a magnifier screen were traced and post instrumentation canal images were compared with the preinstrumentation ones. Changes in canal curvature and the incidence of procedural accidents were analyzed. The results were as follows : Crown-down pressureless technique with nickel-titanium K-files and nickel-titanium engine-driven filing produced no significant changes in canal curvature (p>0.05), while the step-back technique with stainless steel K-files or nickel-titanium K-files (p<0.01) and the crown-down pressureless technique with stainless steel K-files (p<0.05) produced significant changes. With nickel-titanium K-file, crown-down pressureless technique produced significantly less changes in canal curvature than step-back technique (p<0.05), while there was no significant difference between techniques with stainless steel K-files (p>0.05). File types exerted no significant influences in the changes of canal curvature both in the step-back technique and crown-down pressureless technique (0>0.05). Regardless of the file types used, step-back technique produced more procedural accidents such as ledge or elbow formation, apical zipping and apical transportation than the crowndown pressureless technique and nickel-titanium engine-driven filing. Both with stainless steel K-files and with nickel-titanium K-files, the incidence of apical extrusion of canal debris was higher in step-back technique than in crown-down pressureless technique.

  • PDF

MEMS 공정을 통한 마이크로 Pb(Zr,Ti)O3 박막 압전 외팔보 에너지 수확소자의 제작 및 특성 연구 (A Study on the Fabrication and Characterization of Micro Pb(Zr,Ti)O3 Film Piezoelectric Cantilever Using MEMS Process for Energy Harvesting)

  • 이준명;천인우;김문근;권광호;이현우
    • 한국전기전자재료학회논문지
    • /
    • 제26권11호
    • /
    • pp.831-835
    • /
    • 2013
  • In this study, we fabricated a micro $Pb(Zr,Ti)O_3$ (PZT) film piezoelectric cantilever with a Si proof mass and dual beams through MEMS process. The size of the beam and the integrated Si proof mass were about $4,320{\mu}m{\times}290{\mu}m{\times}12{\mu}m$ and $1,380{\mu}m{\times}880{\mu}m{\times}450{\mu}m$ each. To reduce the air damping and have the larger displacement of dual beams was used for design. After mounting micro PZT film piezoelectric cantilever on shaker, we measured the resonance frequency and a output voltage while making resonant frequency changed. The resonant frequency and the highest average power of the cantilever device were 110.2 Hz and 0.36 ${\mu}W$ each, at 0.8 g acceleration and 23.7 $k{\Omega}$ load resistance, respectively.

AVR의 응답속도개선을 위한 제어기법에 관한 연구 (Control techniques for improving response of the AVR)

  • 이형기;김송현;김현수;김기량;김관형
    • 한국정보통신학회논문지
    • /
    • 제19권11호
    • /
    • pp.2534-2539
    • /
    • 2015
  • 발전기의 전압조정장치(AVR)를 이용하여 전압을 조절하는 방식은 기존 아날로그방식과 교체중인 디지털방식을 나눌 수 있다. 일반적으로 브러쉬레스형의 여자시스템을 이용하여 전압을 조절할 경우 전부하에 대하여 전압변동을 작게 하여야 한다. AVR의 제어방법으로 PID(비례-적분-미분)제어방식이 많이 사용되고 있다. 그러나 이 제어기법은 제어대상에 대하여 제어기의 파라미터를 조절하여 과도응답을 줄이고 있다. 따라서 제어대상이 달라질 경우 다시 제어기의 파라미터를 다시 설정해야하는 문제점이 있다. 본 연구에서는 제어대상의 파라미터 변동에 대하여 제어기의 파라미터를 재설정 필요없이 iPID(intelligent PID)제어기를 이용하여 발전기 AVR시스템에 적용하여 전부하 시에도 전압변동이 작은 응답을 얻도록 설계하고 시뮬레이션과 실험을 통하여 과도응답을 개선하였다.

핵연료 계장을 위한 천공조건에 대한 실험적 연구 (An Experimental Study on Drilling Conditions for the Instrumentation of Nuclear Fuel)

  • 홍진태;김가혜;정황영;안성호;정창용
    • 한국정밀공학회지
    • /
    • 제30권1호
    • /
    • pp.113-119
    • /
    • 2013
  • To develop a new nuclear fuel, it needs to make a test fuel rod and carry out burn-up test in the test loop of a research reactor to check the irradiation characteristics of the nuclear fuel. At that time, several sensors such as thermocouples, LVDTs and SPNDs are needed to be attached in and out of the fuel rod and connect them with instrumentation cables. Then, the instrumentation cables deliver the signals measured by the sensors to the measuring device located outside of the reactor pool. In particular, to install a thermocouple in a fuel rod, it needs to drill off holes on the alumina blocks and sintered $UO_2$ pellets. However, because the hardness of a sintered $UO_2$ pellet is 700 Hv (or HRC 61) and that of an alumina block is 1480 Hv, a special drilling machine which adapts a diamond coated drill bit had developed. In this study, several case experiments have been carried out to find an optimal drilling condition of the drilling machine. And, using the optimal drilling condition, minimum numbers of the holes that a drill bit can drill off are verified.

핵의학 영상 물리 및 기기의 최신 동향 (Current Status of Imaging Physics & Instrumentation In Nuclear Medicine)

  • 김희중
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.83-87
    • /
    • 2008
  • 지난 몇 년 동안 핵의학 영상 물리 및 기기 관련 융합영상기기 분야에 많은 발전이 있었다. 최근 몇 년 동안 국내 PET/CT 설치의 급속한 증가는 이들의 임상에서의 역할 및 그 중요성을 입증하고 있다. 그러나 PET/CT는 고가이고, 임상적으로 아직도 그 유용성이 입증되는 과정에 있으며, 특히 치료계획을 위한 장비로는, 미국의 경우 다소 많이 설치되었다는 평가가 공존하고 있다. 또한 저가로 해 결할 수 있는 소프트웨어 융합도 가능하기 때문에 PET 대신 반드시 PET/CT가 필요하다는 주장에는 위의 관점에서 그 한계가 있을 수 있다. 그림에도 불구하고 PET/CT 설치는 계속 증가하고 있어 영상획득 또는 영상판독 모두 PET과 CT 분야의 훈련과 교육이 매우 중요하며 이에 대한 지침서가 발간되었다. PET/CT에 비하여 SPECT/CT는 발전속도가 다소 떨어지지만 이에 대한 지침서도 발간되었다. PET/CT와 SPECT/CT 모두 CT는 앞 부분에 PET과 SPECT는 뒷부분에 설치된다. 이는 환자 영상을 얻을 때 동시에 얻는 것이 아니고 CT영상을 얻은 후 PET과 SPECT영상을 얻게되는 단점이 있다. 이와는 달리 MRI/PET경우 뇌영상을 얻을 때 동시에 MRI와 PET영상을 얻을 수 있어 뇌영상 연구에 큰 도움이 될 것으로 예상하고 있다. 앞으로 기술이 발전함에 따라 전신용 MRI/PET과 유방영상을 위한 PET/US 융합영상장치의 개발 가능성이 매우 높다. 이와 함께 SPECT/CT, PET/CT 및 MRI/PET 기기의 발전도 계속될 것으로 판단된다. 핵의학 영상 물리 및 기기 분야는 최첨단 융합영상 장치의 개발과 함께 하드웨어, 소프트웨어 물리적 특성에 대한 보정기술, 영상 재구성 분야의 다양한 연구도 많은 진전이 필요하다. 또한 영상기기의 설계 및 정량화 기법을 연구하기 위한 몬테카를로 시뮬레이션, 영상장비의 성능평가, 동력학 분석, 선량평가, 움직임 보정 및 융합영상의 정량화 및 분석 기법에 대한 연구도 더욱 활발히 진행될 것으로 예측된다.

Impact of gamma radiation on 8051 microcontroller performance

  • Charu Sharma;Puspalata Rajesh;R.P. Behera;S. Amirthapandian
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4422-4430
    • /
    • 2022
  • Studying the effects of gamma radiation on the instrumentation and control (I&C) system of a nuclear power plant is critical to the successful and reliable operation of the plant. In the accidental scenario, the adverse environment of ionizing radiation affects the performance of the I&C system and it leads to inaccurate and incomprehensible results. This paper reports the effects of gamma radiation on the AT89C51RD2, a commercial-off-the-shelf 8-bit high-performance flash microcontroller. The microcontroller, selected for the device under test for this study is used in the remote terminal unit for a nuclear power plant. The custom circuits were made to test the microcontroller under different gamma doses using a 60Co gamma source in both ex-situ and in-situ modes. The device was exposed to a maximum dose of 1.5 kGy. Under this hostile environment, the performance of the microcontroller was studied in terms of device current and voltage changes. It was observed that the microcontroller device can operate up to a total absorbed dose of approximately 0.6 kGy without any failure or degradation in its performance.

The Fabrication and Characteristics of the Pyroelectric IR Sensor using P(VDF/TrFE) Thin Films Fabricated by the Spin Coating Technique

  • Kwon, Sung-Yeol
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제12C권4호
    • /
    • pp.225-228
    • /
    • 2002
  • The pyroelectric sensor of P(VDF/TrFE) film as sensing materials has been fabricated and evaluated with another commercial pyroelectric sensor using ceramic materials for sensing, The device was mounted in TO-5 housing to detect infrared light of a 5.5~14 ${\mu}{\textrm}{m}$ wavelength. The NEP(noise equivalent power) and specific detectivity D* of the device were 2.13$\times$10$^{-8}$ W and 9.37 10$^{6}$ cm/W under emission energy of 13 ㎼/$\textrm{cm}^2$, respectively.