• Title/Summary/Keyword: Instrumental method

Search Result 390, Processing Time 0.022 seconds

Decentralized Adaptive Control of Interconnected System using Off-Set Modeling (오프셋 모형화 기법을 이용한 상호연관 시스템의 분산형 적응제어)

  • 양흥석;박용식;주성순
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.12
    • /
    • pp.879-883
    • /
    • 1988
  • In this paper, self tuning control of interconnected systems are dealt in view point of large scale system control. The plant model is given in MIMO ARMA procss. This process is simlified as independent SISO ARMA processes having offset terma, which are considered as effects of interconnections. In each decentralized system, self tuning controller with instrumental variable method is adopted. As a result, this algorithm enables the paramter estimation to be unbiased and non-drift. This controller contains a new implicit offset rejection technique. Simulation results consider well with the analysis in case of linear interconnection.

  • PDF

A Test for Autocorrelation in Dynamic Panel Data Models

  • Jung, Ho-Sung
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2005.11a
    • /
    • pp.167-173
    • /
    • 2005
  • This paper presents an autocorrelation test that is applicable to dynamic panel data models with serially correlated errors. The residual-based GMM t-test is a significance test that is applied after estimating a dynamic model by using the instrumental variable(IV) method and is directly applicable to any other consistently estimated residuals. Monte Carlo simulations show that the t-test has considerably more power than the $m_2$ test or the Sargan test under both forms of serial correlation (i.e., AR(1) and MA(1)).

  • PDF

A TEST FOR AUTOCORRELATION IN DYNAMIC PANEL DATA MODELS

  • Jung, Ho-Sung
    • Journal of the Korean Statistical Society
    • /
    • v.34 no.4
    • /
    • pp.367-375
    • /
    • 2005
  • This paper presents an autocorrelation test that is applicable to dynamic panel data models with serially correlated errors. The residual-based GMM t-test is a significance test that is applied after estimating a dynamic model by using the instrumental variable (IV) method and is directly applicable to any other consistently estimated residuals. Monte Carlo simulations show that the t-test has considerably more power than the $m_2$ test or the Sargan test under both forms of serial correlation (i.e., AR(1) and MA(1)).

Seismic characteristics of Tectonic Provinces of The Korean Peninsula (한반도 주요 지체구조구별 지진학적 특성)

  • 이기화
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.64-71
    • /
    • 1999
  • Seismicity of the Korean Peninsula shows intraplate seismicity that has irregular pattern in both time and space. Seismic data of the Korean peninsula consists of historical earthquakes and instrumental earthquakes. In this study we devide these data into complete part and incomplete part and considering earthquake size uncertainty estimate seismic hazard parameters - activity rate λ, b value of Gutenberg-Richter relation and maximum possible earthquake IMAX by statistical method in each major tectonic provinces. These estimated values are expected to be important input parameters in probabilistic seismic hazard analysis and evaluation of design earthquake.

  • PDF

Self-Tuning PID Control of Systems with Time-Varying Delays (시변 지연시간이 존재하는 시스템의 자기동조 PID 제어)

  • 남현도;안동준
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.4
    • /
    • pp.364-370
    • /
    • 1990
  • In this paper, we propose a self-tuning PID controller for unknown systems with time-varying delay. Using pole placement equations, we derive the controller that can be extended to the multi-step time delay case. The time-varying delays are estimated by a prediction error delay method using multiple predictors. Since the order of the estimation vector is not increased, the persistant exciting condition of control input is alleviated. Since the least square method gives biased parameter estimates for colored noise cases, the recursive instrumental variable method is used to estimate system parameters. The computational burden of the proposed method is less than the conventional adaptive methods. Computer simulations are performed to illustrate the efficiency of the proposed method.

  • PDF

Development of Analytical Method for Polychlorinated Biphenyls and Organochlorine Pesticides in Air (대기 중 PCBs와 유기염소계 살충제의 정량을 위한 분석 방법 개발)

  • 최민규;여현규;김태욱;천만영;선우영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.475-485
    • /
    • 2002
  • An analytical method was investigated for the meaiiurement of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) concentrations in air samples. Procedures required for column chromatographic clean up. silicagel (stage I) and gel permeation chromatography (stage II), were discussed. Identification and quantification of PCBs and OCPs were performed using a combination of gas chromatography/mass spectrometry/ selected ion monitoring. Recovery tests calculated from six samples are 68∼137% for PCBs and 58∼130% for OCPs except for endrin aldehyde. Instrumental detection limits determined for the PCBs and OCPs varied from 0.05 to 0.18 pg/m3 and from 0.71 to 16.82 pg/㎥, respectively. The method has been applied to the analysis of air samples collected at Ansung city, Kyonggi province, Korea. This method may serve as a screening protocol for the simultaneous determination of PCBs and OCPs in air.

Transfemoral plug closure of patent Ductus Arteriosus. Experiences in 6 consecutive cases treated without thoracotomy (동맥관 개존증에 대한 비개흉적 폐쇄술: 6례 치험 보고)

  • 강정호
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.542-548
    • /
    • 1985
  • In 1966 Porstmann was the first to successfully apply a new method by which a PDA was closed by a Plug transported by catheters through the femoral artery. We Successfully closed the isolated PDA in 6 consecutive patients using the transfemoral catheter method. To Perform this technique more safely and reliably, some instrumental and technical improvements was made. The Indications for this method have been Expanded to include the cylindrical or window Type ductus as well as the conical-shaped ductus. Classification into three Groups of the configuration of the by Angiography has been useful in selecting the shape of the closing plug. Whenever feasible, we consider the catheter technique to be the method of choice to close the ductus.

  • PDF

Instrumental Assessments of Sub-clinical Skin Reactions induced by Cosmetic Ingredients (화장품 원료에 의해 유도되는 미세 피부반응에 대한 기기적 평가 연구)

  • An, Sang-Mi;Lee, Mi-Young;Baek, Ji-Hwoon;Ham, Hye-In;Boo, Yong-Chool;Koh, Jae-Sook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.1
    • /
    • pp.43-50
    • /
    • 2012
  • The safety of cosmetics or cosmetic ingredients on human skin is generally evaluated by visual assessment but some early subtle skin changes may not be noticed by the naked eyes. Thus, the present study was conducted to detect skin reactions induced by mildly irritating cosmetic ingredients by using a laser Doppler perfusion imager (LDPI) method that measures blood flow, a $Vapometer^{(R)}$ that measure strans epidermal water loss (TEWL), and a spectrophotometer that measures the skin color as the erythema values ($a^*$). Visual assessment showed that all tested oils and humectants except propylene glycol belong to the low skin irritation ranges (grades 0+ to 2.9+) while all tested surfactants and propylene glycol belong to the moderate-to strong-skin irritation ranges (grades 3+ to 5+). Among three instrumental methods, TEWL assessment appeared to be more sensitive than spectrophotometric or LDPI method and suitable for the detection of subtle skin response invisible to the naked eye (grades 0+ to 2.9+). Skin reactions of grade 3+ to 5+ could be detected by all three instrumental methods. In conclusion, the current study suggested that the sub-clinical skin reactions due to mild irritants contained in cosmetics can be best assessed by TEWL measurements.

An Analysis for Success Factors of Social Network Game Towards Farmville Game (소셜네트워크게임의 성공요소분석 : 팜빌 게임을 중심으로)

  • Kim, Jong-Chan;Song, Seung-Keun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.11
    • /
    • pp.2586-2592
    • /
    • 2010
  • Currently social network games with an emphasis on the relationship between the friends, especially women users and the elderly users of over forties, have contributed to the expansion of game market attracting large audiences. Though recent interest in social network games and the explosive propagation of social network game into game industry, scholarly research for social network game is insufficient. The objective of the study is to explore the success factors for successful social network games through the depth interview with game experts. We suggest the guidelines for development of social network game. Commercial success of social network games and the number of users with the best game, farmville, were investigated for understanding key success factors in social network game field. As a result, social interaction, simple interface, asynchronous method, instrumental rationality factors have been identified. This result of the study will expect the guideline in order to develop a successful social network games.

Correction of Accelerogram in Frequency Domain (주파수영역에서의 가속도 기록 보정)

  • Park, Chang Ho;Lee, Dong Guen
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.71-79
    • /
    • 1992
  • In general, the accelerogram of earthquake ground motion or the accelerogram obtained from dynamic tests contain various errors. In these errors of the accelerograms, there are instrumental errors(magnitude and phase distortion) due to the response characteristics of accelerometer and the digitizing error concentrated in low and high frequency components and random errors. Then, these errors may be detrimental to the results of data processing and dynamic analysis. An efficient method which can correct the errors of the accelerogram is proposed in this study. The correction of errors can be accomplished through four steps as followes ; 1) using an interpolation method a data form appropriate to the error correction is prepared, 2) low and high frequency errors of the accelerogram are removed by band-pass filter between prescribed frequency limits, 3) instrumental errors are corrected using dynamic equilibrium equation of the accelerometer, 4) velocity and displacement are obtained by integrating corrected accelerogram. Presently, infinite impulse response(IIR) filter and finite impulse response (FIR) filter are generally used as band-pass filter. In the proposed error correction procedure, the deficiencies of FIR filter and IIR filter are reduced and, using the properties of the differentiation and the integration of Fourier transform, the accuracy of instrument correction and integration is improved.

  • PDF