• 제목/요약/키워드: Instrument Error

검색결과 277건 처리시간 0.025초

DEVELOPMENT OF THE DIGITALIZED AUTOMATIC SEISMIC TRIP SYSTEM FOR NUCLEAR POWER PLANTS USING THE SYSTEMS ENGINEERING APPROACH

  • Jung, Jae Cheon
    • Nuclear Engineering and Technology
    • /
    • 제46권2호
    • /
    • pp.235-246
    • /
    • 2014
  • The automatic seismic trip system (ASTS) continuously monitors PGA (peak ground acceleration) from the seismic wave, and automatically generates a trip signal. This work presents how the system can be designed by using a systems engineering approach under the given regulatory criteria. Overall design stages, from the needs analysis to design verification, have been executed under the defined processes and activities. Moreover, this work contributes two significant design areas for digitalized ASTS. These are firstly, how to categorize the ASTS if the ASTS has a backed up function of the manual reactor trip, and secondly, how to set the requirements using the given design practices either in overseas ASTS design or similar design. In addition, the methodology for determining the setpoint can be applied to the I&C design and development project which needs to justify the error sources correctly. The systematic approach that has been developed and realized in this work can be utilized in designing new I&C (instrument and control system) as well.

직류분전류를 포함한 과전류에 대한 변류기의 출력특성 (Output performance of current transformer on over-current)

  • 정흥수;나대열;김선구;노창일;김원만;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.951-953
    • /
    • 2005
  • The current transformer is used for the insulation of measuring instrument, enlargement of measurement scope, standardization of measuring instrument, control of protective device. It's required various performance as the intention of service, site of establishment, insulation. especailly, current transformer has small ratio errors. if current transformer has large ratio error, it's caused a electricity failure. so in this paper, we examine the theory of current transformer, major factor of errors, output performance on over-current.

  • PDF

초등학생용 과학의 본성 검사 도구 개발 및 타당성 검토 (Development and Feasibility Study of the Nature of Science Instrument for Elementary School Students)

  • 박재현;박재용
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제41권4호
    • /
    • pp.701-724
    • /
    • 2022
  • 이 연구에서는 과학의 본성(NOS)에 대한 초등학생들의 인식을 구체적으로 드러내기 위해 개방형 질문지 형식의 초등학생용 NOS 검사 도구를 개발하였고, 그 타당도와 효과를 조사하였다. 초등학생용 NOS 검사 도구를 개발하기 위해 기존 NOS 검사 도구를 초등학생들에게 적용할 때 발생할 수 있는 문제점을 분석하였고, 이를 토대로 검사 도구의 개발 방향을 설정하였다. 또한 초등학생의 수준에 적합한 7가지 NOS 유형을 선정한 후, 유형별로 기존의 검사 도구 문항을 수정·보완하거나 새로운 문항을 개발하여 예비 검사 도구를 제작하였으며, 과학교육 전문가 그룹의 내용 타당도 검증을 거쳐 최종적으로 NOS의 각 유형과 관련된 7개 문항에 '과학에 대한 포괄적 인식'을 묻는 1개 문항을 추가하여 총 8개 문항으로 구성된 NOS 검사 도구를 개발하였다. 개발한 검사 도구의 실질적 효과를 검증하기 위해 서울에 있는 두 초등학교에서 6학년 2개 학급 50명의 학생을 대상으로, 한 학급에서는 '기존 검사 도구→개발 검사 도구', 다른 학급에서는 '개발 검사 도구→기존 검사 도구'의 순서로 사전·사후 검사를 실행하였고, 수집된 자료는 요약적 내용분석을 통해 비교 평가하고 Wilcoxon 부호 순위 검정을 실행하여 분석하였다. 기존 NOS 검사 도구와 개발한 NOS 검사 도구에 대해 학생들이 응답한 내용을 비교·분석한 결과, 개발한 검사 도구를 사용할 때 NOS에 대한 학생들의 관점이 더 다양하게 나타났고, 문항의 의도를 잘못 해석하여 발생했던 응답의 오류가 줄어들었다. 또한 개발한 검사 도구를 사용할 때 통계적으로 유의미한 수준에서 과반 정도 학생들의 응답 내용이 더 구체적으로 변화하였다. 이 연구에서는 이러한 결과를 바탕으로 초등학생들에게 적합한 NOS 검사 도구의 개발을 위한 시사점을 논의하였다.

사이버공간과 사회조사:온라인 사회조사의 쟁점과 과제 (Cyberspace and survey research: The methodological implications and issues of online survey research)

  • 조동기
    • 한국조사연구학회지:조사연구
    • /
    • 제1권1호
    • /
    • pp.73-108
    • /
    • 2000
  • 사이버공간이 독특한 사회적 공간으로 자리잡고 이에 대한 경험적 자료의 필요성이 중대됨에 따라 컴퓨터 통신망을 이용한 사회조사가 늘어나고 있다. 본 연구는 사이버공간이 보여주는 기술적 기능성을 방법론적으로 검토해 봄으로써 온라인 사회조사의 발전가능성을 탐색하고 있다. 온라인 사회조사는 표집틀, 응답자 접촉방식, 질문지 형태 등에 따라 회원 조사, 방문자조사, 전자우편조사, 전자설문조사로 구분될 수 있으며 기존의 조사방법에 비하여 조사비용의 저렴하고 조사의 실행이 용이하다는 특징을 가지고 있다. 그러나 체계적 오차와 관련하여 온라인 사회조사는 표본설계(모집단의 규정, 표집틀 오차, 추출오차), 측정(측정도구의 구성, 시스템의 안정성과 충실성, 비 응답 및 응답오차) 조사윤리의 측면에서 많은 과제를 안고 있다. 이러한 방법론적인 쟁점에 대한 충분한 고려가 이루어질 때 온라인 사회조사는 본격적인 조사연구의 한 방법으로 자리잡을 수 있을 것이다.

  • PDF

Research on the Basic Rodrigues Rotation in the Conversion of Point Clouds Coordinate System

  • Xu, Maolin;Wei, Jiaxing;Xiu, Hongling
    • Journal of Information Processing Systems
    • /
    • 제16권1호
    • /
    • pp.120-131
    • /
    • 2020
  • In order to solve the problem of point clouds coordinate conversion of non-directional scanners, this paper proposes a basic Rodrigues rotation method. Specifically, we convert the 6 degree-of-freedom (6-DOF) rotation and translation matrix into the uniaxial rotation matrix, and establish the equation of objective vector conversion based on the basic Rodrigues rotation scheme. We demonstrate the applicability of the new method by using a bar-shaped emboss point clouds as experimental input, the three-axis error and three-term error as validate indicators. The results suggest that the new method does not need linearization and is suitable for optional rotation angle. Meanwhile, the new method achieves the seamless splicing of point clouds. Furthermore, the coordinate conversion scheme proposed in this paper performs superiority by comparing with the iterative closest point (ICP) conversion method. Therefore, the basic Rodrigues rotation method is not only regarded as a suitable tool to achieve the conversion of point clouds, but also provides certain reference and guidance for similar projects.

Approximations of Optimal Calibration Experimental Designs Using Gaussian Influence Diagrams

  • Kim, Sung-Chul
    • Journal of the Korean Statistical Society
    • /
    • 제22권2호
    • /
    • pp.219-234
    • /
    • 1993
  • A measuring instrument must be calibrated for accurate inferences of an unknown quantity. Bayesian calibration designs with respect to squared error loss based on a linear model are discussed in Kim and Barlow (1992). In this paper, we consider approximations of the optimal calibration designs using the idea of Gaussian inflence diagrams. The approximation is evaluated by means of numerical calculations, where it is compared with the exact values from the numerical integration.

  • PDF

DIFFRACTION ANALYSIS OF LAMOST - TWO SEGMENTED MIRRORS INCLUDED

  • Xu WENLI
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.399-400
    • /
    • 1996
  • LAMOST is a special reflecting Schmidt telescope. Both the refleting Schmidt plate $M_A$ and the spherical primary mitrror $M_B$ are segmened mirrors. These two cofocus but not co-phase. The diffraction of the optical system is decided by the shape overlapping of $M_A$ and $M_B$. This paper describes the diffraction caculating results with different declination and different field angle. The diffraction influence to the image quality is acceptable in the error buget of optical system. It also proves that the size seletion of the sub-mirror is reasonable.

  • PDF

스텝방법을 이용한 광대역지진계 센서(STS-2)의 검증 (Calibration of the Broadband Sensor(STS-2) using the Step Method)

  • 류용규;이덕기;이전희;오석훈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.11-18
    • /
    • 2001
  • A close examination of the step calibrations for STS-2 seismometers installed by KMA has been done to deduce the response parameters of those instrument including angular corner frequency, damping factor and coil constant factor. A non-linear least square inversion method has been apple iud to estimate these parameters. The estimated parameters coincide with the manufactory specification with less than 1% error. This method will be extended near- future to deduce the response parameters for SS-1 short period seismometer.

  • PDF

기록치 오차와 유역모형의 검정(I) - 기록치 내의 측정 오차 분석 - (Errors in Recorded Information and Calibration of a Catchment Modelling System(I) - Analysis of Measurement Errors in Recorded Information -)

  • Kyung Sook Choi;James E. Ball
    • 한국농공학회지
    • /
    • 제45권5호
    • /
    • pp.110-116
    • /
    • 2003
  • A catchment modelling system is the summation of the numerous hydrologic, hydraulic and other process models necessary to simulate the response of a catchment to a storm event. Differences between the recorded catchment response and that predicted by a catchment modelling system can arise from structural errors within the catchment modelling system, evaluation errors in the control parameters, or measurement errors in the recorded data being used to assess the reliability of the evaluation of the control parameters. Presented herein is an investigation of the potential measurement errors within the recorded information, which was considered to occur from instrument error in the ultra sonic flow monitor. This investigation was undertaken using three available rating curves at the Musgrave Avenue Stormwater System in Centennial Park, Sydney, developed by Abustan (1997), Water Board (1994), and using Manning's equation.