• Title/Summary/Keyword: Instrument Error

Search Result 275, Processing Time 0.022 seconds

Error Rate and Flight Characteristics of Rotary-Wing Aircraft Pilots Under Low Visibility Conditions (저시정 조건에서 회전익 항공기 조종사 에러 발생율 및 비행특성)

  • Se-Hoon Yim;Young Jin Cho
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.1
    • /
    • pp.60-67
    • /
    • 2024
  • The majority of civil aviation accidents are caused by human factors, and especially for rotary-wing aircraft, accidents often occur in situations where pilots unexpectedly or unintentionally enter into instrument meteorological conditions (IIMC). This research analyzed the error rates of rotary-wing aircraft pilots under low visibility conditions from various angles to gain insights into flight characteristics and to explore measures to reduce accidents in IIMC situations. The occurrence rate of errors by pilots under low visibility conditions was examined using a flight simulator equipped with motion, with 65 pilots participating in the experiment. Flight data obtained through the experiment were used to aggregate and analyze the number of errors under various conditions, such as reductions in flight visibility, the presence or absence of spatial disorientation, and the pilot's qualifications. The analysis revealed peculiarities in flight characteristics under various conditions, and significant differences were found in the rate of error occurrence according to the pilot's qualification level, possession of instrument flight rules (IFR) qualifications, and during different phases of flight. The results of this research are expected to contribute significantly to the prevention of aircraft accidents in IIMC situations by improving pilot education and training programs.

$H_{\infty}$ filter for flexure deformation and lever arm effect compensation in M/S INS integration

  • Liu, Xixiang;Xu, Xiaosu;Wang, Lihui;Li, Yinyin;Liu, Yiting
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.3
    • /
    • pp.626-637
    • /
    • 2014
  • On ship, especially on large ship, the flexure deformation between Master (M)/Slave (S) Inertial Navigation System (INS) is a key factor which determines the accuracy of the integrated system of M/S INS. In engineering this flexure deformation will be increased with the added ship size. In the M/S INS integrated system, the attitude error between MINS and SINS cannot really reflect the misalignment angle change of SINS due to the flexure deformation. At the same time, the flexure deformation will bring the change of the lever arm size, which further induces the uncertainty of lever arm velocity, resulting in the velocity matching error. To solve this problem, a $H_{\infty}$ algorithm is proposed, in which the attitude and velocity matching error caused by deformation is considered as measurement noise with limited energy, and measurement noise will be restrained by the robustness of $H_{\infty}$ filter. Based on the classical "attitude plus velocity" matching method, the progress of M/S INS information fusion is simulated and compared by using three kinds of schemes, which are known and unknown flexure deformation with standard Kalman filter, and unknown flexure deformation with $H_{\infty}$ filter, respectively. Simulation results indicate that $H_{\infty}$ filter can effectively improve the accuracy of information fusion when flexure deformation is unknown but non-ignorable.

Compact and precision range finder using self-mixing semiconductor laser

  • Shinohara, Shigenobu;Andou, Minoru;Yoshida, Hirofumi;Ikeda, Hiroaki;Miyata, Masafumi;Yoshida, Jun-Ichi;Nishide, Ken-Ichi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.972-978
    • /
    • 1989
  • Proposed is improved compact self-mixing type semiconductor-laser range finder, which measures mode-hop time interval (MHI). Measurement error caused by the fluctuation of MHI is greatly reduced by averaging many contiguous MHI's. The main cause of measurement error 1.5% at ranges from 0.1m to 0.8m is attributed to the optical phase change of a returned light from a focusing lens. Accuracy improvement by stabilization of the returned light is suggested.

  • PDF

A Study on Management for Measuring Instrument of Small and Medium-sized Enterprises (중소제조업체의 측정기 운영에 관한 실증적 연구)

  • Yoo, Jae Kwon;Yoo, Hyun-Jong
    • Journal of Industrial Convergence
    • /
    • v.6 no.2
    • /
    • pp.43-56
    • /
    • 2008
  • Measurement is used for evaluation of product or process exactly. If it couldn't measured correctly, Quality-cost must be raised and it would be hard to improve product quality. So, this study suggests improvement guide line for the multilateral problems of measuring instrument operation based on the investigation of 157 small and medium-sized enterprises in February, 2008. To use measuring instrument correctly, man who treat it must be accustomed with the structure, the performance, the method. The instrument is selected properly for the measurement goal. If not, results couldn't be correctly or wasted time, efforts, and costs. When selecting a instrument, the tolerance, the size, the figure, the material, and the efficiency must be considered. If the measuring instruments are controlled efficiently, it could be accomplished that improving product quality and coinciding with the goal of QM.

  • PDF

The Economic Design of $\bar{x}$ -S Chart Considering Measurement Error (측정오차를 고려한 $\bar{x}$ -S 관리도의 경제적 설계)

  • 유영창;강창욱
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.61
    • /
    • pp.89-98
    • /
    • 2000
  • For statistical process control, the process data are collected by the measurement system. But, the measurement system may have instrument error or/and operator error. In the measured values of products, the total observed variance consists of process variance and variance due to error of measurement system. In this paper, we design more practical T-s control chart considering estimated measurement error The effects of measurement error on the expected total cost and design parameters are investigated.

  • PDF

Delay Characteristics and Sound Quality of Space Based Digital Waveguide Model (공간 기준 디지털 도파관 모델의 지연 특성과 합성음의 음질)

  • 강명수;김규년
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.8
    • /
    • pp.680-686
    • /
    • 2003
  • Digital waveguide model is a general method that is used in physical modeling of musical instruments. Wave motion is analyzed by time or by space in digital waveguide model. Because sampling is made via time, it is general that musical instrument model is described by wave motion of time. In this paper, we synthesized the musical instrument sound by adding instrument body model to the spatial based string model. In this way, we could improve sound quality and process musical instrument model's tone control variables effectively. We explained about delay error that happens in string and body in space based sampling and showed method to process fractional delay using FD (Fractional Delay)filter. Finally, we explained the relation between tone quality and number of delays. And we also compared the result with time base digital waveguide model.

3D Orientation and Position Tracking System of Surgical Instrument with Optical Tracker and Internal Vision Sensor (광추적기와 내부 비전센서를 이용한 수술도구의 3차원 자세 및 위치 추적 시스템)

  • Joe, Young Jin;Oh, Hyun Min;Kim, Min Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.579-584
    • /
    • 2016
  • When surgical instruments are tracked in an image-guided surgical navigation system, a stereo vision system with high accuracy is generally used, which is called optical tracker. However, this optical tracker has the disadvantage that a line-of-sight between the tracker and surgical instrument must be maintained. Therefore, to complement the disadvantage of optical tracking systems, an internal vision sensor is attached to a surgical instrument in this paper. Monitoring the target marker pattern attached on patient with this vision sensor, this surgical instrument is possible to be tracked even when the line-of-sight of the optical tracker is occluded. To verify the system's effectiveness, a series of basic experiments is carried out. Lastly, an integration experiment is conducted. The experimental results show that rotational error is bounded to max $1.32^{\circ}$ and mean $0.35^{\circ}$, and translation error is in max 1.72mm and mean 0.58mm. Finally, it is confirmed that the proposed tool tracking method using an internal vision sensor is useful and effective to overcome the occlusion problem of the optical tracker.

A Study on Effective Management for Measuring Instrument (측정기의 효율적 운영에 관한 실증적 연구)

  • Yoo, Hyun-Jong;Jung, Soo-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.1
    • /
    • pp.183-190
    • /
    • 2008
  • Measurement is a essential part in all kinds of industry, especially in manufacturing. But until now, measurement hasn't been located to the core of manufacturing in domestic. This study suggests improvement guide line for the multilateral problems of measuring instrument operation based on the investigation of small and medium-sized enterprises. To use measuring instrument correctly, man who treat it must be accustomed with the structure, the performance, the method. The measuring instrument must be corrected periodically. The correcting-schedule is established with environments with considering accuracy, stability, purpose, condition, and frequency.

Process and instrument faults detection based on steam generator model (증기발생기 모델을 이용한 계통 및 계측기 고장검출에 관한 연구)

  • Kim, Jung-Soo;Lyou, Joon;Na, Nan-Ju;Kwon, Kee-Choon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.250-255
    • /
    • 1993
  • In this paper, for detection and isolation of instrument and process faults related with steam generator(S/G) in nuclear power plant, two types of observers are designed based on the linearized dynamic model of S/G : a bank of Dedicated Observers (DOS) for instrument faults detection and a bank of Unknown Input Observers(UIO) for process faults detection. And then, they are combined to decide which one between the above two faults occurs. In principle, the failure in ith instrument(process) can be isolated by monitoring the error between the ith output and its estimation obtained from the ith DOS(UIO). It is shown via computer simulations that the present scheme is feasible in finding out the source of a fault.

  • PDF