Browse > Article
http://dx.doi.org/10.5370/JEET.2016.11.5.1342

Ratio Correction Factor and Phase Displacement at Arbitrary Burdens in Instrument Transformers  

Jung, Jae Kap (Corresponding Author: Korea Research Institute of Standards and Science, Korea.)
Kim, Kyu-Tae (Korea Research Institute of Standards and Science, Korea.)
Lee, Young Seob (Korea University of Science and Technology, Korea.)
Publication Information
Journal of Electrical Engineering and Technology / v.11, no.5, 2016 , pp. 1342-1347 More about this Journal
Keywords
Instrument transformer; Ratio error; Ratio correction factor; Phase displacement; Burden; Equivalent circuit; Expanded uncertainty;
Citations & Related Records
연도 인용수 순위
  • Reference
1 W. J. M. Moore, P. N. Miljanic, The Current Comparator, Peter Peregrinus Ltd., London, United Kingdom, 1988.
2 P. N. Miljanic, E. So, An improved current-comparatorbased 1000 A transconductance amplifier for the in-situ calibration of transformer loss measuring systems, IEEE Trans. Power Delivery 8 (3) (1993) 861-865.   DOI
3 E. So, E. Hanique, In-situ calibration of high-voltage three-phase transformer loss measuring systems, IEEE Trans. Instrum. Meas. 50 (2) (2001) 422-425.   DOI
4 A. H. M. Arnold, Current-transformer testing J. IEE 74 (449) (1934) 424-444.
5 A. Braun, Determination of current transformer errors at primary currents up to 100 000 A , IEEE Trans. Instrum. Meas. IM-26 (3) (1977) 263-267.
6 International Electrotechnical Commission 1996 Instrument Transformers: Part 1. Current Transformers IEC 60044-1 (Geneva: International Electrotechnical Commission) pp. 28
7 American National Standard Requirements for Instrument Transformers, Am. Natl. Stands. Instit., (ANSI/IEEE) C57.13-1978 (reaffirmed, 1986), New York.
8 J. K. Das, Determination of characteristics of a three-winding potential transformer and predetermination of errors, I. E. Journal-EL 51 (1970) 51-58.
9 F. K. Harris, W. C. Sze, N. L. Kusters, O. Petersons, W. J. M. Moore, An international comparison of voltage-transformer calibration to 350 kV, IEEE Trans. Communications and Electronics 70 (1964) 18-19.
10 P. J. Betts, Calculated temperature coefficients of transformers, Australia National Measurement Laboratory Technical Paper No. 4, 1977.
11 J. K. Jung, Calibration Procedure of Voltage Transformer in KRISS, Doc. No. C-13-2-0120-2006 (E), 2006.
12 J. D. Ramboz, O. Petersons, A calibration service for current transformers, NIST Measurement Services, Special Publication 250-36, 1991.
13 J. K. Jung, S. W. Kwon, S. H. Lee, Y. T. Park, A study on usefulness verification technique of the measurement system by the difference between calculated and experimental values of ratio error/phase angle error in current transformer, Trans. KIEE. 53C (2004) 213-217.
14 Bishay catalog (www.vishay.com).
15 H. W. Price, C. K. Duff, Effects of magnetic leakage in current transformers, University of Toronto Research Bulletin No. 2, 167-90, 1921
16 W. E. Anderson, A calibration service for voltage transformers and high-voltage capacitors, NBS Measurement Services Special Publication 250-33 12-3, 1988.
17 J. K. Jung, Calibration Procedure of Current Transformer in KRISS, Doc. No. C-13-2-0100-2006 (E), 2006.