• Title/Summary/Keyword: Instrument Control

Search Result 987, Processing Time 0.029 seconds

A Study of the Retina Image Controllability using a Sledge (망막 영상 조절 장치에 관한 연구)

  • 이숙희;이영춘;양연식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.273-276
    • /
    • 1997
  • Seeing is an intelligent act. Retina is the most important part among the components of eye which is comprised of iris, pupil, lens, optic disk, and so forth. Because retina acts like a photo receiver to detect light from every object, if damaged, animals have a severe problem to live along with themselves and sometimes they lose their sight. In the ophthalmology, doctors use special instrument to see exact retina image of object and operate the surgery by rotating focus control knob. In this study, a basic test is done to achieve the auto focus control instrument. Specially made sledge and attenuator are installed on the optic bed to change the distance and laser power between the first reflective mirror and the second one. Control panel which is compiled by Visual C t t to control stepping motors ,laser power and photodiode are implemented with ADA-board.

  • PDF

Computer based Control and Monitoring using LabVIEW (LabVIEW를 활용한 컴퓨터 기반의 제어 및 모니터링)

  • 송민규;김광동;제도흥;노덕규;한석태;위석오;오세진
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10b
    • /
    • pp.478-480
    • /
    • 2004
  • Virtual Instrument는 컴퓨터를 Main controller로 두어 사용자가 필요로 하는 요소들을 연결하여 컴퓨터 속의 가상 공간에 사용자가 정의한 instrument를 구현하는 것을 그 기본 개념으로 한다. Virtual Instrument를 통하여 사용자는 여러 기능 및 함수를 소프트웨어적으로 추가할 수 있어 기존 방식에 비하여 보다 효율적으로 시스템 업그레이드 및 최적화를 수행할 수 있다. 또한 컴퓨터의 성능이 향상됨에 따라 Virtual Instrument의 성능도 증가하게 되는 기술적 이점을 얻을 수 있고 사용환경이 누구에게나 익숙하기 때문에 작업의 효율을 극대화시킬 수 있다 이러한 여러 효율성에 근거하여 나온 개념이 컴퓨터 기반의 제어 및 모니터링으로써 향후 네트워크 기술을 수용하여 더욱 발전될 것으로 전망되고 있다.

  • PDF

A New Instrument for Early Detection of Alzheimer's Disease

  • Muraoka, Tetsuya;Nagata, Tomohiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2362-2366
    • /
    • 2003
  • The paper describes a new instrument for early detection of Alzheimer's disease. A new instrument for early detection of Alzheimer's disease is constructed on both the questionnaire for the investigation of living environment, and the lists for the functional tests of the sense, the physiology, and the left and right brains. When the medical doctor has made a diagnosis of Alzheimer's disease, the demented patient does not recover the indication adding available treatments. Then, the indication of a patient only takes a turn for the worse. For the demented patient can be kept his/her life style, Alzheimer's disease can make an early detection using a new instrument before a diagnosis of the dementia. And the indication of a demented patient can be delayed by the available medical treatments.

  • PDF

A Fault Detection and Diagnosis in a PWR Steam Generator (PWM 증기발생기의 고장검출 및 진단에 관한 연구)

  • Park, Seung-Yub
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.1
    • /
    • pp.120-127
    • /
    • 1991
  • The purpose of this study is to develop a fault detection and diagnosis scheme that can monitor process fault and instrument fault of a steam generator. The suggested scheme consists of a Kalman filter and two bias estimators. Method of detecting process and instrument fault in a steam generator uses the mean test on the residual sequence of Kalman filter, designed for the unfailed system, to make a fault decision. Once a fault is detected, two bias estimators are driven to estimate the fault and to discriminate process fault and instrument fault. In case of process fault, the fault diagnosis of outlet temperature, feed-water heater and main steam control value is considered. In instrument fault, the fault diagnosis of steam genrator's three instruments is considered. Computer simulation tests show that on-line prompt fault detection and diagnosis can be performed very successfully.

  • PDF

Development of a multi-channel clinical chemistry analyzer (반사광을 이용한 다채널 임상화학분석기개발)

  • 유동주;송은영
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.139-148
    • /
    • 1995
  • In this paper we report the device of a multi-channel clinical instrument developed for determi¬nation of the levels of the urinary urobilinogen, glucose, ketone, bilirubin, protein, ascorbic acid, nitrite, pH, occult-blood, specific gravity, and leukocytes semiquantitatively. The test parameters are expressed on the dry test strips as a range of color intensities by chemical reactions. The instrument measures the value of each substance by reading the reflectance light emanated from the test strips. We also designed the reagent strip cassette and loader in order to intercept the outside interference. The loader can be operated semi-automatically. The light source is consisted on light emitting diodes at three specific wavelengths (560 nm, 610 nm, 650 nm). Precision of the system was evaluated by testing a series of commercial control urine samples. Furthermore, the performance of the instrument was compared with two other test methods on the urine samples from 100 persons. Our results showed a good repeatability between tests and a satisfactory agreement between the readings by our instrument and visual evaluation.

  • PDF

Process and instrument faults detection based on steam generator model (증기발생기 모델을 이용한 계통 및 계측기 고장검출에 관한 연구)

  • Kim, Jung-Soo;Lyou, Joon;Na, Nan-Ju;Kwon, Kee-Choon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.250-255
    • /
    • 1993
  • In this paper, for detection and isolation of instrument and process faults related with steam generator(S/G) in nuclear power plant, two types of observers are designed based on the linearized dynamic model of S/G : a bank of Dedicated Observers (DOS) for instrument faults detection and a bank of Unknown Input Observers(UIO) for process faults detection. And then, they are combined to decide which one between the above two faults occurs. In principle, the failure in ith instrument(process) can be isolated by monitoring the error between the ith output and its estimation obtained from the ith DOS(UIO). It is shown via computer simulations that the present scheme is feasible in finding out the source of a fault.

  • PDF

The Analysis for the characteristics about the Digital Control CT & PT (디지털 제어형 CT 및 PT에 관한 특성 분석)

  • Shin, Jung-Eun;Kim, Jae-Chul;Song, Seung-Youp;Kwon, Young-Mok;Kim, On-Suk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.456-459
    • /
    • 2004
  • Generally, instrument transformer of the core type have been used for measuring current. Because instrument transformer has defects, electronic instrument was appeared. Electronic instrument has many merit-linearity, small size, low cost, etc. Rogowski coil is typical electronic CT and R-divider is typical electronic VT. This paper is introduced a basic concept and theory of electronic current transformer, electronic voltage transformer.

  • PDF

Preliminary Design of Power Control and Distribution Unit for LEO Application (저궤도 위성 응용을 위한 전력조절분배기 설계)

  • Park, Sung-Woo;Park, Hee-Sung;Jang, Jin-Baek;Jang, Sung-Soo;Lee, Sang-Kon
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.55-57
    • /
    • 2007
  • A Power control and Distribution Unit (PCDU) plays roles of protection of battery against overcharge by active control of solar array generated power, distribution of unregulated electrical power via controlled outlets to bus and instrument units, distribution of regulated electrical power to selected bus and instrument units, and provision of status monitoring and telecommand interface allowing the system and ground operate the power system, evaluate its performance and initiate appropriate countermeasures in case of abnormal conditions. In this work, we perform the preliminary design of a PCDU for the small Low Earth Orbit (LEO) Satellite applications. The main constitutes of the PCDU are the battery interface module, solar array regulators with maximum power point tracking (MPPT) technology, heater power distribution modules, internal converter modules for regulated bus voltage generation, power distribution modules of unregulated and regulated primary bus, and instrument power distribution modules.

  • PDF

The Application of Boiler Digital Control System 3D MMI Using Virtual Real (보일러 분산제어 시스템 3차원 MMI 구현)

  • Oh, Young-Il;Kim, Eung-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.880-882
    • /
    • 1999
  • Virtual Reality is a set of computer technologies which, when combined, provide an interface to a computer-generated world, and in particular, provide such a convincing interface that the user believes he is actually in a three dimensional computer-generated world. This computer generated world may be a model of a real-world object, such as a house; it might be an world that does not exist in a real sense but is understood by humans, such as a chemical molecule or a representation of a set of data; or it might be in a completely imaginary science fiction world. this paper describes the application of boiler digital control system MMI for power plant using virtual reality

  • PDF

Radiative transfer analysis for Amon-Ra instrument

  • Seong, Se-Hyun;Ryu, Dong-Ok;Lee, Jae-Min;Hong, Jin-Suk;Kim, Seong-Hui;Yoon, Jee-Yeon;Park, Won-Hyun;Lee, Han-Shin;Park, Jong-Soo;Yu, Ji-Woong;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.28.4-29
    • /
    • 2009
  • The 'Amon-Ra' instrument of the proposed 'EARTHSHINE' satellite is a dual (i.e. imaging and energy) channel instrument for monitoring the total solar irradiance (TSI) and the Earth's irradiance at around the L1 halo orbit. Earlier studies for this instrument include, but not limited to, design and construction of breadboard Amon-Ra imaging channel, stray light suppression and system performance computation using Integrated Ray Tracing (IRT) technique. The Amon-Ra instrument is required to produce 0.3% in uncertainty for both Sunlight and Earthlight measurement. In this study, we report accurate estimation of the output electric signal derived from the orbital variation of radiant exitance from the Sun and the Earth arriving at the aperture and detector plane of the Amon-Ra. For this, orbital irradiance are computed analytically first and then confirmed by simulation using Integrated Ray Tracing (IRT) model. Specially, the results show the arriving power at the bolometer detector surface is $1.24{\mu}W$ for the Sunlight and $1.28{\mu}W$ for the Earthlight, producing the output signal pulses of 34.31 mV and 35.47 mV respectively. These results demonstrate successfully that the arriving radiative power is well within the bolometer detector dynamic range and, therefore, the proposed detector can be used for the in-orbit measurement sequence. We discuss the computational details and implications as well as the simulation results.

  • PDF