• 제목/요약/키워드: Instrument Accuracy

검색결과 335건 처리시간 0.023초

대구경 렌즈의 형상 측정을 위한 Fizeau 간섭계 시스템 개발 (Development of a Fizeau Interferometer System for Measuring the Profile of Large Optical Lens)

  • 배광환;이응석;이기암;김옥현
    • 대한기계학회논문집A
    • /
    • 제30권12호
    • /
    • pp.1649-1657
    • /
    • 2006
  • Fizeau interferometer is well known optical instrument for measuring the lens profile accurately. The object of this study is focused on the design and optical measuring techniques for large optical components, such as a reflection mirror for astronomical purpose. Measuring of large optical lens, the object could not be moved as small one but the measuring instrument must be moved for the alignment, because of the geometric conditions and the accuracy of the stage. Therefore, a five axis stage is designed to align the Interferometer instead of the measuring object. This instrument will be used for an on machine measuring system in polishing machine for large optical lens.

공리적 기법에 의한 품질 향상 방안 (Product's quality improvement plane of parts for Injection Molding using Axiomatic approach)

  • 배진우;박홍석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.355-356
    • /
    • 2006
  • This paper proposes an Molding error compensation method that improves accuracy with geometry information of injected parts using three-dimensional measuring instrument. a traditional mold design has been conducted by an experience-based trial and error, whereby generally the mold designer would decide the gate location and processing conditions. as a natural consequence, almost all creats inferior goods. It's just a process of trial and error and caught in a vicious circle. Due to this reason, this paper uses a three-dimensional measuring instrument, a commercial analysis package of injection molding(Moldflow, MPI) to analysis a state of flux. In addition to that axiomatic approach.

  • PDF

자동차 계기용 소형 스텝모터 및 미소 스텝 구동 IC 설계에 관한 연구 (A study on the design of a small step motor and micro step driving IC for an automotive instrument)

  • 이종배;성하경;정중기;류세현;임준홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.247-249
    • /
    • 2001
  • In our research, we designed a small step motor with 2-phase structure and a micro step driving IC, which is used in an automotive instrument. The step motor for the automotive instrument has the better advantages than a cross coil type motor. These advantages are the characteristics with a good linearity, a fine accuracy, a low noise and so on.

  • PDF

스키환자용 특수 슬관절보조기의 동특성 해석 (Dynamic Analysis of The Knee Brace for Ski Injuried Patient)

  • 최진영;김명회;장대진;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.893-898
    • /
    • 2003
  • A new type of the Expanded Knee brace was developed to measure the human knee joint. This instrument was composed of six parts, four arranged for two hinge joints and two pin joint , and two hinge for the expanded system. With a developed instrument, the experimental results obtained the data of Accelerometer, the experimental results obtained of the data FEM, the experimental results obtained the data of Motion Analysis and Force platform. Compared to earlier developed sports type knee brace, new instrument shows its convenience in application and accuracy in measurement.

  • PDF

반도체소자를 이용한 관전압계의 개발 (The development of tube voltage meter using the semiconductor)

  • 선종률;신대철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제25권2호
    • /
    • pp.71-75
    • /
    • 2002
  • 검출능력이 우수하고 가격이 저렴하며 소형으로 제작할 수 있는 반도체검출기 중에서도 광전소지인 포토다이오드를 이용하였는데 이 소자는 특정표면이 입사광에 대하여 반응을 나타내는 소자인데 광 강도가 증가함에 따라 저항이 감소하는 특성을 이용하여 방사선 검출기를 제작하였다. 제작된 측정기는 접속식 측정기에 의해 검사치를 측정하여 기준치를 정하고 기존의 비접속형 측정기를 이용하여 제작된 비접속형 측정기와 정확성을 비교 검토하였다. 비교 결과 3가지 측정기의 모든 측정치가 기준치 범위에 속하였으며 정밀도를 분석하기 위하여 백분율 평균오차의 평균치를 구하였는데 기준측정기의 백분율평균오차의 평균치가 -0.02이고 비교측정기가 -0.22, 제작한 측정기가 0.17이었다.

  • PDF

머시닝 센터에서 하중이 위치결정정밀도에 미치는 영향 (The effect on the position precision by load in M.C.)

  • 이승수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 춘계학술대회 논문집
    • /
    • pp.143-147
    • /
    • 1998
  • As the accuracy of manufactured goods needed high-accuracy processing has made the efficiency of NC and measurment technology develop, the innovation of machine tools has influence the development of the semi-conductor and optical technology. We can mention that a traction role of the acceleration for the development like that depends on the development of the measurement technics - Stylus instrument method, STM, SEM, Laser interferometer method - which are used for measuring the movement accuracy of machine tools. The movement error factors in movement accuracy are expressed as yaw, roll, and pitch etc. Machining center has 21 movement error factors including of 3 axies joint errors because that has 3 axies and has been measured as the standard of the unloaded condition until now inspite of getting static, dynamic, and servo-gain errors in the case of expending the error range. Therefore, this study tries to measure position accuracy according to loading on the X-Y table of the machining center.

  • PDF

광추적기와 내부 비전센서를 이용한 수술도구의 3차원 자세 및 위치 추적 시스템 (3D Orientation and Position Tracking System of Surgical Instrument with Optical Tracker and Internal Vision Sensor)

  • 조영진;오현민;김민영
    • 제어로봇시스템학회논문지
    • /
    • 제22권8호
    • /
    • pp.579-584
    • /
    • 2016
  • When surgical instruments are tracked in an image-guided surgical navigation system, a stereo vision system with high accuracy is generally used, which is called optical tracker. However, this optical tracker has the disadvantage that a line-of-sight between the tracker and surgical instrument must be maintained. Therefore, to complement the disadvantage of optical tracking systems, an internal vision sensor is attached to a surgical instrument in this paper. Monitoring the target marker pattern attached on patient with this vision sensor, this surgical instrument is possible to be tracked even when the line-of-sight of the optical tracker is occluded. To verify the system's effectiveness, a series of basic experiments is carried out. Lastly, an integration experiment is conducted. The experimental results show that rotational error is bounded to max $1.32^{\circ}$ and mean $0.35^{\circ}$, and translation error is in max 1.72mm and mean 0.58mm. Finally, it is confirmed that the proposed tool tracking method using an internal vision sensor is useful and effective to overcome the occlusion problem of the optical tracker.

Adaptive Extraction Method for Phase Foreground Region in Laser Interferometry of Gear

  • Xian Wang;Yichao Zhao;Chaoyang Ju;Chaoyong Zhang
    • Current Optics and Photonics
    • /
    • 제7권4호
    • /
    • pp.387-397
    • /
    • 2023
  • Tooth surface shape error is an important parameter in gear accuracy evaluation. When tooth surface shape error is measured by laser interferometry, the gear interferogram is highly distorted and the gray level distribution is not uniform. Therefore, it is important for gear interferometry to extract the foreground region from the gear interference fringe image directly and accurately. This paper presents an approach for foreground extraction in gear interference images by leveraging the sinusoidal variation characteristics shown by the interference fringes. A gray level mask with an adaptive threshold is established to capture the relevant features, while a local variance evaluation function is employed to analyze the fluctuation state of the interference image and derive a repair mask. By combining these masks, the foreground region is directly extracted. Comparative evaluations using qualitative and quantitative assessment methods are performed to compare the proposed algorithm with both reference results and traditional approaches. The experimental findings reveal a remarkable degree of matching between the algorithm and the reference results. As a result, this method shows great potential for widespread application in the foreground extraction of gear interference images.

혀 저항정확도훈련이 만성 뇌졸중 환자의 혀 근력과 구어기능에 미치는 영향 (The Effects of Tongue Pressure Strength and Accuracy Training on Tongue Strength and Speech Function of Chronic Stroke Patients)

  • 김보중;마성룡
    • 한국콘텐츠학회논문지
    • /
    • 제17권11호
    • /
    • pp.156-166
    • /
    • 2017
  • 본 연구는 만성 뇌졸중 환자들을 대상으로, 혀의 객관적인 수치로 측정할 수 있는 기계(Iowa Oral Performance Instrument, IOPI)를 사용하여 혀의 최대 저항 훈련프로그램을 수정하고, 혀 정확도 훈련을 추가한 프로그램을 적용하여 혀 근력과 구어기능에 미치는 효과를 비교하고자 실시하였다. 뇌졸중으로 진단받은 입원 및 외래환자를 각각 20명씩 실험군인 혀 저항정확도훈련 치료군과 대조군인 구강안면운동 치료군으로 나누어 각 치료를 대상자들에게 총 4주간 30분씩, 주 5회 실시하였고, 혀 근력과 구어기능 능력을 변화를 알아보기 위해 중재 전, 후에 혀 전방거상 압력(Anterior Tongue Pressure; ATP), 혀 후방거상 압력(Posterior Tongue Pressure; PTP), 최대발성시간(Maximum Phonation Time; MPT)을 측정하였다. 본 연구의 결과 중재 전 후 혀 저항정확도훈련 치료군과 구강안면운동 치료군의 혀 근력과 구어기능은 유의하게 향상하였으나, 두 군 사이의 비교에서 혀 저항정확도훈련 치료군과 구강안면운동 치료군 간의 혀 근력과 구어기능의 변화량은 유의한 차이가 없었다. 따라서 혀 저항정확도훈련이 기존 구강안면운동 치료보다 혀 근력 및 구어기능 향상에 효과적이지는 않은 것으로 나타났다.

복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고- (A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF